Skip to main content

Research Repository

Advanced Search

All Outputs (73)

Tracking the neurodevelopmental trajectory of beta band oscillations with optically pumped magnetometer-based magnetoencephalography (2024)
Journal Article

Neural oscillations mediate the coordination of activity within and between brain networks, supporting cognition and behaviour. How these processes develop throughout childhood is not only an important neuroscientific question but could also shed lig... Read More about Tracking the neurodevelopmental trajectory of beta band oscillations with optically pumped magnetometer-based magnetoencephalography.

Post‐task responses following working memory and movement are driven by transient spectral bursts with similar characteristics (2024)
Journal Article

The post-movement beta rebound has been studied extensively using magnetoencephalography (MEG) and is reliably modulated by various task parameters as well as illness. Our recent study showed that rebounds, which we generalise as “post-task responses... Read More about Post‐task responses following working memory and movement are driven by transient spectral bursts with similar characteristics.

Tri-axial rubidium and helium optically pumped magnetometers for on-scalp magnetoencephalography recording of interictal epileptiform discharges: a case study (2023)
Journal Article

Cryogenic magnetoencephalography (MEG) enhances the presurgical assessment of refractory focal epilepsy (RFE). Optically pumped magnetometers (OPMs) are cryogen-free sensors that enable on-scalp MEG recordings. Here, we investigate the application of... Read More about Tri-axial rubidium and helium optically pumped magnetometers for on-scalp magnetoencephalography recording of interictal epileptiform discharges: a case study.

An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts (2023)
Journal Article

The signal space separation (SSS) method is routinely employed in the analysis of multichannel magnetic field recordings (such as magnetoencephalography (MEG) data). In the SSS method, signal vectors are posed as a multipole expansion of the magnetic... Read More about An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts.

Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding (2023)
Journal Article

The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to... Read More about Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding.

Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers (2023)
Journal Article

Magneto- and electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio... Read More about Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers.