Skip to main content

Research Repository

Advanced Search

All Outputs (7)

Sensorless Speed Control of a Fault-Tolerant Five-Phase PMSM Drives (2020)
Journal Article
Saleh, K., & Sumner, M. (2020). Sensorless Speed Control of a Fault-Tolerant Five-Phase PMSM Drives. Electric Power Components and Systems, 48(9-10), 919-932. https://doi.org/10.1080/15325008.2020.1825555

This paper introduces a novel method to achieve sensorless speed control of a Five-phase Permanent Magnet Synchronous Motor (PMSM) drive in case of a single-phase open-circuit fault regardless which phase is open. The motor performance when an open c... Read More about Sensorless Speed Control of a Fault-Tolerant Five-Phase PMSM Drives.

Time-domain Assessment of Data Transmission Errors in Systems with Multiple DC/DC Converters (2020)
Conference Proceeding
Niewiadomski, K., Lezynski, P., Smolenski, R., Bojarski, J., Sumner, M., & Thomas, D. W. P. (2020). Time-domain Assessment of Data Transmission Errors in Systems with Multiple DC/DC Converters. . https://doi.org/10.1109/emceurope48519.2020.9245673

In this paper a statistical approach to quantify time-domain impact of common mode (CM) voltage induced on a communication system by the operation of several DC/DC converters is presented. The mathematical formulation of a problem of conducted electr... Read More about Time-domain Assessment of Data Transmission Errors in Systems with Multiple DC/DC Converters.

An Open Source, FPGA-Based Bit Error Ratio Tester for Serial Communications (2020)
Conference Proceeding
Basford, M. J., Pena-Quintal, A. E., Greedy, S., Sumner, M., & Thomas, D. W. P. (2020). An Open Source, FPGA-Based Bit Error Ratio Tester for Serial Communications. In Proceedings of 2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE. https://doi.org/10.1109/emceurope48519.2020.9245786

This paper discusses the design of a FPGA-based Bit Error Ratio (BER) measurement system in a serial communication link under electromagnetic emissions. The BER measurement is an important figure for the reliability of digital communication systems.... Read More about An Open Source, FPGA-Based Bit Error Ratio Tester for Serial Communications.

Power Quality Analysis (0-2kHz) in DC/DC Converters under Steady State and Transient Conditions (2020)
Conference Proceeding
Khilnani, A. D., Niewiadomski, K., Rose, C., Sumner, M., Thomas, D. W. P., Ballukja, E., …Mariscotti, A. (2020). Power Quality Analysis (0-2kHz) in DC/DC Converters under Steady State and Transient Conditions. . https://doi.org/10.1109/emceurope48519.2020.9245758

The aim of this paper is to understand the effects of low frequency (0-2kHz) conducted emissions on power quality from a microgrid based DC/DC converter under steady state and transient loading conditions. The experimental data obtained from the lab... Read More about Power Quality Analysis (0-2kHz) in DC/DC Converters under Steady State and Transient Conditions.

Performance Assessment of an Energy Management System for a Home Microgrid with PV Generation (2020)
Journal Article
Elkazaz, M., Sumner, M., Pholboon, S., Davies, R., & Thomas, D. (2020). Performance Assessment of an Energy Management System for a Home Microgrid with PV Generation. Energies, 13(13), https://doi.org/10.3390/en13133436

Home energy management systems (HEMS) are a key technology for managing future electricity distribution systems as they can shift household electricity usage away from peak consumption times and can reduce the amount of local generation penetrating i... Read More about Performance Assessment of an Energy Management System for a Home Microgrid with PV Generation.

A Fault Location Scheme for Active Untransposed Distribution Systems Using a Limited Number of Synchronized Measurements (2020)
Journal Article
Aboshady, F., Thomas, D., & Sumner, M. (2020). A Fault Location Scheme for Active Untransposed Distribution Systems Using a Limited Number of Synchronized Measurements. Electric Power Components and Systems, 48(1-2), 1-11. https://doi.org/10.1080/15325008.2020.1731880

This paper presents a fault location scheme for unbalanced and untransposed distribution systems which contain different types of distributed generation (DG). A general formula has been derived for any fault type using a limited number of synchronize... Read More about A Fault Location Scheme for Active Untransposed Distribution Systems Using a Limited Number of Synchronized Measurements.

Fault Ride-Through Power Electronic Topologies for Hybrid Energy Storage Systems (2020)
Journal Article
Georgious, R., Garcia, J., Sumner, M., Saeed, S., & Garcia, P. (2020). Fault Ride-Through Power Electronic Topologies for Hybrid Energy Storage Systems. Energies, 13(1), https://doi.org/10.3390/en13010257

This work presents a fault ride-through control scheme for a non-isolated power topology used in a hybrid energy storage system designed for DC microgrids. The hybrid system is formed by a lithium-ion battery bank and a supercapacitor module, both co... Read More about Fault Ride-Through Power Electronic Topologies for Hybrid Energy Storage Systems.