Skip to main content

Research Repository

Advanced Search

All Outputs (3)

Marine power distribution system fault location using a portable injection unit (2014)
Journal Article
Jia, K., Bi, T., Liu, B., Christopher, E., Thomas, D. W., & Sumner, M. (2015). Marine power distribution system fault location using a portable injection unit. IEEE Transactions on Power Delivery, 30(2), https://doi.org/10.1109/TPWRD.2014.2364259

A portable injection unit for Active Impedance Estimation (AIE) is built and tested in a DC zonal marine power distribution system to provide useful information for system protection and restoration. The portable unit generates current “spikes” and i... Read More about Marine power distribution system fault location using a portable injection unit.

Real time parameter estimation for power quality control and intelligent protection of grid-connected power electronic converters (2014)
Journal Article
Sumner, M., Abusorrah, A., Thomas, D. W., & Zanchetta, P. (2014). Real time parameter estimation for power quality control and intelligent protection of grid-connected power electronic converters. IEEE Transactions on Smart Grid, 5(4), https://doi.org/10.1109/TSG.2014.2298495

This paper presents a method to identify power system impedance in real-time using signals obtained from grid- connected power electronic converters. The proposed impedance estimation has potential applications in renewable/distributed energy systems... Read More about Real time parameter estimation for power quality control and intelligent protection of grid-connected power electronic converters.

Advanced DC zonal marine power system protection (2014)
Journal Article
Jia, K., Christopher, E., Thomas, D. W., & Sumner, M. (2014). Advanced DC zonal marine power system protection. IET Generation, Transmission and Distribution, 8(2), https://doi.org/10.1049/iet-gtd.2013.0139

A new Active Impedance Estimation (AIE) based protection strategy which is suitable for utilization in a DC zonal marine power distribution system is presented. This method uses two triangular current "spikes" injections for system impedance estimati... Read More about Advanced DC zonal marine power system protection.