A parametric study on the performance characteristics of an evacuated flat-plate photovoltaic/thermal (PV/T) collector (2020)
Journal Article
Hu, M., Guo, C., Zhao, B., Ao, X., Suhendri, Cao, J., …Pei, G. (2021). A parametric study on the performance characteristics of an evacuated flat-plate photovoltaic/thermal (PV/T) collector. Renewable Energy, 167, 884-898. https://doi.org/10.1016/j.renene.2020.12.008

An evacuated flat-plate photovoltaic/thermal (E-PV/T) collector was proposed. The inner space of the E-PV/T collector is vacuumed to suppress non-radiative heat losses, thus increasing thermal efficiency of the collector. Therefore, the E-PV/T collec... Read More about A parametric study on the performance characteristics of an evacuated flat-plate photovoltaic/thermal (PV/T) collector.

Implementation of Passive Radiative Cooling Technology in Buildings: A Review (2020)
Journal Article
Suhendri, S., Hu, M., Su, Y., Darkwa, J., & Riffat, S. (2020). Implementation of Passive Radiative Cooling Technology in Buildings: A Review. Buildings, 10(12), 1-28. https://doi.org/10.3390/buildings10120215

Radiative cooling (RC) is attracting more interest from building engineers and architects. Using the sky as the heat sink, a radiative cooling material can be passively cooled by emitting heat to the sky. As a result of the development of material te... Read More about Implementation of Passive Radiative Cooling Technology in Buildings: A Review.

Droplet entrainment within the evaporator to the suitable volume-filling ratio of a vertical two-phase closed thermosyphon (2020)
Journal Article
Zhang, T., Yan, Z., Wang, L., Zheng, W., Su, Y., & Zheng, R. (2021). Droplet entrainment within the evaporator to the suitable volume-filling ratio of a vertical two-phase closed thermosyphon. International Journal of Thermal Sciences, 159, Article 106576. https://doi.org/10.1016/j.ijthermalsci.2020.106576

The present study on vertical two-phase closed thermosyphon (TPCT) is aimed to determine the suitable volume-filling ratio, as a function of geometries, heat flux and vapor temperature, in order to avoid the potential local dryout in the evaporator s... Read More about Droplet entrainment within the evaporator to the suitable volume-filling ratio of a vertical two-phase closed thermosyphon.

Effect of the spectrally selective features of the cover and emitter combination on radiative cooling performance (2020)
Journal Article
Hu, M., Suhendri, Zhao, B., Ao, X., Cao, J., Wang, Q., …Pei, G. (2021). Effect of the spectrally selective features of the cover and emitter combination on radiative cooling performance. Energy and Built Environment, 2(3), 251-259. https://doi.org/10.1016/j.enbenv.2020.06.008

Radiative cooling (RC) shows good potential for building energy saving by throwing waste heat to the cosmos in a passive and sustainable manner. However, most available radiative coolers suffer from low cooling flux. The situation becomes even deteri... Read More about Effect of the spectrally selective features of the cover and emitter combination on radiative cooling performance.

Advanced parametric louver systems with bi-axis and two-layer designs for an extensive daylighting coverage in a deep-plan office room (2020)
Journal Article
Eltaweel, A., Su, Y., Lv, Q., & Lv, H. (2020). Advanced parametric louver systems with bi-axis and two-layer designs for an extensive daylighting coverage in a deep-plan office room. Solar Energy, 206, 596-613. https://doi.org/10.1016/j.solener.2020.06.035

Advanced daylighting systems have become commonly used in modern architecture for a more sustainable environment. The mainstream of recent daylighting studies focuses not only on the quantity but also the quality of daylight delivered to an interior... Read More about Advanced parametric louver systems with bi-axis and two-layer designs for an extensive daylighting coverage in a deep-plan office room.