A Parallel Connected Unfolding Bridge (PCUB) Multilevel Converter for HVDC Applications (2019)
Conference Proceeding
Hassan, Z., Costabeber, A., Tardelli, F., Watson, A., & Clare, J. (2019). A Parallel Connected Unfolding Bridge (PCUB) Multilevel Converter for HVDC Applications. In IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society (5703-5708). https://doi.org/10.1109/IECON.2019.8927297

© 2019 IEEE. Hybrid Voltage Source Converters (VSC), that combine the conventional three-level VSCs and Modular Multilevel Chain-Links (CLs), offer a promising solution for future HVDC stations, achieving reduced footprint with respect to the MMC whi... Read More about A Parallel Connected Unfolding Bridge (PCUB) Multilevel Converter for HVDC Applications.

A Fast Diagnosis Method for Both IGBT Faults and Current Sensor Faults in Grid-Tied Three-Phase Inverters With Two Current Sensors (2019)
Journal Article
Li, Z., Wheeler, P., Watson, A., Costabeber, A., Wang, B., Ren, Y., …Ma, H. (2020). A Fast Diagnosis Method for Both IGBT Faults and Current Sensor Faults in Grid-Tied Three-Phase Inverters With Two Current Sensors. IEEE Transactions on Power Electronics, 35(5), 5267-5278. https://doi.org/10.1109/tpel.2019.2946692

© 1986-2012 IEEE. This article considers fault detection in the case of a three-phase three-wire (3P3W) inverter, when only two current sensors are used to save cost or due to a faulty current sensor. With two current sensors, there is no current met... Read More about A Fast Diagnosis Method for Both IGBT Faults and Current Sensor Faults in Grid-Tied Three-Phase Inverters With Two Current Sensors.

A Nonintrusive IGBT Open-Circuit Fault and Current Sensor Fault Diagnosis Method for Grid-Tied Three-phase Three-Wire Inverter with Two Current Sensors (2019)
Conference Proceeding
Li, Z., Wheeler, P., Watson, A., Costabeber, A., Bai, Z., Zhang, X., …Ma, H. (2019). A Nonintrusive IGBT Open-Circuit Fault and Current Sensor Fault Diagnosis Method for Grid-Tied Three-phase Three-Wire Inverter with Two Current Sensors. In 2019 IEEE Energy Conversion Congress and Exposition (ECCE) (2963-2967). https://doi.org/10.1109/ECCE.2019.8912813

© 2019 IEEE. In some cases, only two current sensors are available in three-phase three-wire (3P3W) inverters. This occurs when one of three sensors is faulty, or the inverter is equipped with only two sensors to save cost. There has been no method a... Read More about A Nonintrusive IGBT Open-Circuit Fault and Current Sensor Fault Diagnosis Method for Grid-Tied Three-phase Three-Wire Inverter with Two Current Sensors.