Skip to main content

Research Repository

Advanced Search

All Outputs (35)

A novel, robust, and portable platform for magnetoencephalography using optically-pumped magnetometers (2024)
Journal Article
Schofield, H., Hill, R. M., Feys, O., Holmes, N., Osborne, J., Doyle, C., Bobela, D., Corvilain, P., Wens, V., Rier, L., Bowtell, R., Ferez, M., Mullinger, K. J., Coleman, S., Rhodes, N., Rea, M., Tanner, Z., Boto, E., de Tiège, X., Shah, V., & Brookes, M. J. (2024). A novel, robust, and portable platform for magnetoencephalography using optically-pumped magnetometers. Imaging Neuroscience, 2, 1-22. https://doi.org/10.1162/imag_a_00283

Magnetoencephalography (MEG) measures brain function via assessment of magnetic fields generated by neural currents. Conventional MEG uses superconducting sensors, which place significant limitations on performance, practicality, and deployment; howe... Read More about A novel, robust, and portable platform for magnetoencephalography using optically-pumped magnetometers.

Tracking the neurodevelopmental trajectory of beta band oscillations with optically pumped magnetometer-based magnetoencephalography (2024)
Journal Article
Rier, L., Rhodes, N., Pakenham, D. O., Boto, E., Holmes, N., Hill, R. M., Reina Rivero, G., Shah, V., Doyle, C., Osborne, J., Bowtell, R. W., Taylor, M., & Brookes, M. J. (2024). Tracking the neurodevelopmental trajectory of beta band oscillations with optically pumped magnetometer-based magnetoencephalography. eLife, 13, Article RP94561. https://doi.org/10.7554/elife.94561.3

Neural oscillations mediate the coordination of activity within and between brain networks, supporting cognition and behaviour. How these processes develop throughout childhood is not only an important neuroscientific question but could also shed lig... Read More about Tracking the neurodevelopmental trajectory of beta band oscillations with optically pumped magnetometer-based magnetoencephalography.

Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System (2024)
Journal Article
Bardouille, T., Smith, V., Vajda, E., Leslie, C. D., & Holmes, N. (2024). Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System. Sensors, 24(11), Article 3503. https://doi.org/10.3390/s24113503

Magnetoencephalography (MEG) non-invasively provides important information about human brain electrophysiology. The growing use of optically pumped magnetometers (OPM) for MEG, as opposed to fixed arrays of cryogenic sensors, has opened the door for... Read More about Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System.

Simultaneous whole-head electrophysiological recordings using EEG and OPM-MEG (2024)
Journal Article
Seedat, Z. A., Pier, K. S., Holmes, N., Rea, M., Al-Hilaly, L., Tierney, T. M., Embury, C. M., Pardington, R., Mullinger, K. J., Cross, J. H., Boto, E., & Brookes, M. J. (2024). Simultaneous whole-head electrophysiological recordings using EEG and OPM-MEG. Imaging Neuroscience, 2, 1-15. https://doi.org/10.1162/imag_a_00179

Electroencephalography (EEG) and magnetoencephalography (MEG) non-invasively measure human brain electrophysiology. They differ in nature; MEG offers better performance whilst EEG (a wearable platform) is more practical. They are also complementary,... Read More about Simultaneous whole-head electrophysiological recordings using EEG and OPM-MEG.

The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG study (2024)
Journal Article
Rier, L., Rhodes, N., Pakenham, D., Boto, E., Holmes, N., Hill, R. M., Rivero, G. R., Shah, V., Doyle, C., Osborne, J., Bowtell, R., Taylor, M. J., & Brookes, M. J. (2024). The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG study. eLife, Article 94561v1. https://doi.org/10.7554/eLife.94561.1

Neural oscillations mediate coordination of activity within and between brain networks, supporting cognition and behaviour. How these processes develop throughout childhood is not only a critical neuroscientific question but could also shed light on... Read More about The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG study.

Designing Optimal Loop, Saddle, and Ellipse-Based Magnetic Coils by Spherical Harmonic Mapping (2023)
Journal Article
Hobson, P. J., Hardwicke, N. L., Davis, A., Smith, T. X., Morley, C., Packer, M., Holmes, N., Weil, M. A., Brookes, M. J., Bowtell, R., & Fromhold, M. (2023). Designing Optimal Loop, Saddle, and Ellipse-Based Magnetic Coils by Spherical Harmonic Mapping. IEEE Transactions on Instrumentation and Measurement, 72, Article 1005815. https://doi.org/10.1109/TIM.2023.3284138

Adaptable, low-cost, coils designed by carefully selecting the arrangements and geometries of simple primitive units are used to generate magnetic fields for diverse applications. These extend from magnetic resonance and fundamental physics experimen... Read More about Designing Optimal Loop, Saddle, and Ellipse-Based Magnetic Coils by Spherical Harmonic Mapping.

Tri-axial rubidium and helium optically pumped magnetometers for on-scalp magnetoencephalography recording of interictal epileptiform discharges: a case study (2023)
Journal Article
Feys, O., Corvilain, P., Labyt, E., Mahmoudzadeh, M., Routier, L., Sculier, C., Holmes, N., Brookes, M., Goldman, S., Romain, R., Mitryukovskiy, S., Palacios-Laloy, A., Schwartz, D., Betrouni, N., Derambure, P., Wallois, F., Wens, V., & De Tiège, X. (2023). Tri-axial rubidium and helium optically pumped magnetometers for on-scalp magnetoencephalography recording of interictal epileptiform discharges: a case study. Frontiers in Neuroscience, 17, Article 1284262. https://doi.org/10.3389/fnins.2023.1284262

Cryogenic magnetoencephalography (MEG) enhances the presurgical assessment of refractory focal epilepsy (RFE). Optically pumped magnetometers (OPMs) are cryogen-free sensors that enable on-scalp MEG recordings. Here, we investigate the application of... Read More about Tri-axial rubidium and helium optically pumped magnetometers for on-scalp magnetoencephalography recording of interictal epileptiform discharges: a case study.

Portable single-beam cesium zero-field magnetometer for magnetocardiography (2023)
Journal Article
Dawson, R., O'Dwyer, C., Mrozowski, M. S., Irwin, E., McGilligan, J. P., Burt, D. P., Hunter, D., Ingleby, S., Rea, M., Holmes, N., Brookes, M. J., Griffin, P. F., & Riis, E. (2023). Portable single-beam cesium zero-field magnetometer for magnetocardiography. Journal of Optical Microsystems, 3(4), Article 044501. https://doi.org/10.1117/1.jom.3.4.044501

Optically pumped magnetometers (OPMs) are becoming common in the realm of biomagnetic measurements. We discuss the development of a prototype zero-field cesium portable OPM and its miniaturized components. Zero-field sensors operate in a very low sta... Read More about Portable single-beam cesium zero-field magnetometer for magnetocardiography.

Test-retest reliability of the human connectome: An OPM-MEG study (2023)
Journal Article
Rier, L., Michelmann, S., Ritz, H., Shah, V., Hill, R. M., Osborne, J., Doyle, C., Holmes, N., Bowtell, R., Brookes, M. J., Norman, K. A., Hasson, U., Cohen, J. D., & Boto, E. (2023). Test-retest reliability of the human connectome: An OPM-MEG study. Imaging Neuroscience, 1, 1-20. https://doi.org/10.1162/imag_a_00020

Magnetoencephalography with optically pumped magnetometers (OPM-MEG) offers a new way to record electrophysiological brain function, with significant advantages over conventional MEG, including adaptability to head shape/size, free movement during sc... Read More about Test-retest reliability of the human connectome: An OPM-MEG study.

Benchtop magnetic shielding for benchmarking atomic magnetometers (2023)
Journal Article
Hobson, P. J., Holmes, N., Patel, P., Styles, B., Chalmers, J., Morley, C., Davis, A., Packer, M., Smith, T. X., Raudonyte, S., Holmes, D., Harrison, R., Woolger, D., Sims, D., Brookes, M. J., Bowtell, R., & Fromhold, M. (2023). Benchtop magnetic shielding for benchmarking atomic magnetometers. IEEE Transactions on Instrumentation and Measurement, 72, Article 6007309. https://doi.org/10.1109/tim.2023.3293540

Here, a benchtop hybrid magnetic shield containing four mumetal cylinders and nine internal flexible printed circuit boards is designed, constructed, tested, and operated. The shield is designed specifically as a test-bed for building and operating u... Read More about Benchtop magnetic shielding for benchmarking atomic magnetometers.

An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts (2023)
Journal Article
Holmes, N., Bowtell, R., Brookes, M. J., & Taulu, S. (2023). An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts. Sensors, 23(14), Article 6537. https://doi.org/10.3390/s23146537

The signal space separation (SSS) method is routinely employed in the analysis of multichannel magnetic field recordings (such as magnetoencephalography (MEG) data). In the SSS method, signal vectors are posed as a multipole expansion of the magnetic... Read More about An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts.

Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023)
Journal Article
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., Glover, P., Montague, P. R., Brookes, M. J., & Bowtell, R. (2023). Naturalistic Hyperscanning with Wearable Magnetoencephalography. Sensors, 23(12), Article 5454. https://doi.org/10.3390/s23125454

The evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substra... Read More about Naturalistic Hyperscanning with Wearable Magnetoencephalography.

Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding (2023)
Journal Article
Holmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., Shah, V., Osborne, J., Fromhold, T. M., Glover, P., Brookes, M. J., & Bowtell, R. (2023). Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding. NeuroImage, 274, Article 120157. https://doi.org/10.1016/j.neuroimage.2023.120157

The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to... Read More about Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding.

Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers (2023)
Journal Article
Hillebrand, A., Holmes, N., Sijsma, N., O’Neill, G. C., Tierney, T. M., Liberton, N., Stam, A. H., van Klink, N., Stam, C. J., Bowtell, R., Brookes, M. J., & Barnes, G. R. (2023). Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers. Scientific Reports, 13(1), Article 4623. https://doi.org/10.1038/s41598-023-31111-y

Magneto- and electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio... Read More about Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers.

Measurement of Frontal Midline Theta Oscillations using OPM-MEG (2023)
Journal Article
Rhodes, N., Rea, M., Boto, E., Rier, L., Shah, V., Hill, R. M., Osborne, J., Doyle, C., Holmes, N., Coleman, S. C., Mullinger, K., Bowtell, R., & Brookes, M. J. (2023). Measurement of Frontal Midline Theta Oscillations using OPM-MEG. NeuroImage, 271, Article 120024. https://doi.org/10.1016/j.neuroimage.2023.120024

Optically pumped magnetometers (OPMs) are an emerging lightweight and compact sensor that can measure magnetic fields generated by the human brain. OPMs enable construction of wearable magnetoencephalography (MEG) systems, which offer advantages over... Read More about Measurement of Frontal Midline Theta Oscillations using OPM-MEG.

Turning OPM-MEG into a Wearable Technology (2022)
Book Chapter
Rhodes, N., Holmes, N., Hill, R., Barnes, G., Bowtell, R., Brookes, M., & Boto, E. (2022). Turning OPM-MEG into a Wearable Technology. In E. Labyt, T. Sander, & R. Wakai (Eds.), Flexible High Performance Magnetic Field Sensors: On-Scalp Magnetoencephalography and Other Applications (195-223). Springer International Publishing. https://doi.org/10.1007/978-3-031-05363-4_11

This chapter explores the use of optically pumped magnetometers (OPMs) as a tool for magnetoencephalography (MEG). Conventional MEG systems use superconducting quantum interference devices (SQUIDs) to measure the femto-Tesla-level magnetic fields at... Read More about Turning OPM-MEG into a Wearable Technology.

A lightweight magnetically shielded room with active shielding (2022)
Journal Article
Holmes, N., Rea, M., Chalmers, J., Leggett, J., Edwards, L. J., Nell, P., Pink, S., Patel, P., Wood, J., Murby, N., Woolger, D., Dawson, E., Mariani, C., Tierney, T. M., Mellor, S., O’Neill, G. C., Boto, E., Hill, R. M., Shah, V., Osborne, J., …Bowtell, R. (2022). A lightweight magnetically shielded room with active shielding. Scientific Reports, 12, Article 13561. https://doi.org/10.1038/s41598-022-17346-1

Magnetically shielded rooms (MSRs) use multiple layers of materials such as MuMetal to screen external magnetic fields that would otherwise interfere with high precision magnetic field measurements such as magnetoencephalography (MEG). Optically pump... Read More about A lightweight magnetically shielded room with active shielding.