Skip to main content

Research Repository

Advanced Search

All Outputs (5)

Intra-tracheal multiplexed sensing of contact pressure and perfusion (2021)
Journal Article
Correia, R., Gadsby, B., Korposh, S., Norris, A. M., Hayes-Gill, B. R., Sinha, R., …Morgan, S. P. (2022). Intra-tracheal multiplexed sensing of contact pressure and perfusion. Biomedical Optics Express, 13(1), 48-64. https://doi.org/10.1364/BOE.442165

Incorrect endotracheal tube (ETT) cuff inflation pressure causes significant problems for intubated patients. The technical development and first in vivo use of a smart ETT for measurements at the cuff-trachea interface during mechanical ventilation... Read More about Intra-tracheal multiplexed sensing of contact pressure and perfusion.

Localised plasmonic hybridisation mode optical fibre sensing of relative humidity (2021)
Journal Article
Liu, L. L., Korposh, S., Gomez, D., Correia, R., Hayes-Gill, B. R., & Morgan, S. P. (2022). Localised plasmonic hybridisation mode optical fibre sensing of relative humidity. Sensors and Actuators B: Chemical, 353, Article 131157. https://doi.org/10.1016/j.snb.2021.131157

This work reports an optical fibre probe functionalised with ‘cotton-shaped’ gold-silica nanostructures for relative humidity (RH) monitoring. The sensor response utilises the localised surface plasmon resonance (LSPR) of self-assembled nanostructure... Read More about Localised plasmonic hybridisation mode optical fibre sensing of relative humidity.

Optical Fibre Sensor for Capillary Refill Time and Contact Pressure Measurements under the Foot (2021)
Journal Article
Ballaji, H. K., Correia, R., Liu, C., Korposh, S., Hayes-Gill, B. R., Musgrove, A., & Morgan, S. P. (2021). Optical Fibre Sensor for Capillary Refill Time and Contact Pressure Measurements under the Foot. Sensors, 21(18), Article 6072. https://doi.org/10.3390/s21186072

Capillary refill time (CRT) refers to the time taken for body tissue to regain its colour after an applied blanching pressure is released. Usually, pressure is manually applied and not measured. Upon release of pressure, simple mental counting is typ... Read More about Optical Fibre Sensor for Capillary Refill Time and Contact Pressure Measurements under the Foot.

Optical fibre Sensor for Simultaneous Temperature and Relative Humidity Measurement: Towards Absolute Humidity Evaluation (2021)
Journal Article
He, C., Korposh, S., Correia, R., Liu, L., Hayes-Gill, B. R., & Morgan, S. P. (2021). Optical fibre Sensor for Simultaneous Temperature and Relative Humidity Measurement: Towards Absolute Humidity Evaluation. Sensors and Actuators B: Chemical, 344, Article 130154. https://doi.org/10.1016/j.snb.2021.130154

Temperature and humidity are essential parameters in monitoring the health of patients in critical care. An optical fibre sensor has been developed for simultaneous measurement of relative humidity (RH) and temperature at a single optical fibre tip b... Read More about Optical fibre Sensor for Simultaneous Temperature and Relative Humidity Measurement: Towards Absolute Humidity Evaluation.

Monica Healthcare: From the research laboratory to commercial reality—A real‐life case study (2021)
Journal Article
Hayes‐Gill, B. R. (2021). Monica Healthcare: From the research laboratory to commercial reality—A real‐life case study. Health Technology Letters, 8(1), 1-10. https://doi.org/10.1049/htl2.12004

The desire of many engineers is to see their work end up as a final product offering a real benefit to society—for a lecturer/professor at a university, this is a dream often out of reach of the majority. However, the university academic is a changed... Read More about Monica Healthcare: From the research laboratory to commercial reality—A real‐life case study.