Al-Hussein Abu-Jalala
Performance improvement of simplified synchronous generators using an active power filter
Abu-Jalala, Al-Hussein; Cox, Tom; Gerada, C.; Rashed, Mohamed
Authors
Dr Tom Cox T.Cox@nottingham.ac.uk
ASSOCIATE PROFESSOR
Professor CHRISTOPHER GERADA CHRIS.GERADA@NOTTINGHAM.AC.UK
PROFESSOR OF ELECTRICAL MACHINES
Mohamed Rashed
Abstract
Active power filters (APF) are used to improve power quality and are commonly connected in parallel with the load at the point of common coupling (PCC). They are used to compensate for harmonics from nonlinear loads, for reactive power compensation and/or balancing mains currents. This paper will investigate the effect of using an APF to improve the output power quality of a simplified synchronous generator (SSG) with distorted back-EMF. The work will further investigate the use of an APF in parallel to improve the transient response of synchronous generator without damper bars, in order to control the dynamic response from a sudden change in the connected load. Using an APF, simulation results show significant improvements in both generator output current quality and transient response to load step changes without damper bars.
Citation
Abu-Jalala, A.-H., Cox, T., Gerada, C., & Rashed, M. Performance improvement of simplified synchronous generators using an active power filter. Presented at Energy Conversion Congress and Exposition (ECCE) 2017
Conference Name | Energy Conversion Congress and Exposition (ECCE) 2017 |
---|---|
End Date | Oct 5, 2017 |
Acceptance Date | May 1, 2017 |
Publication Date | Nov 7, 2017 |
Deposit Date | Feb 26, 2018 |
Publicly Available Date | Feb 26, 2018 |
Peer Reviewed | Peer Reviewed |
Keywords | Synchronous generator, Damper bars, Skewless generator, Active power filter, Four legs converter, Finite element analysis |
Public URL | https://nottingham-repository.worktribe.com/output/893357 |
Publisher URL | http://ieeexplore.ieee.org/abstract/document/8096019/ |
Additional Information | © 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. |
Contract Date | Feb 26, 2018 |
Files
Performance improvement of simplified synchronous generators using an active power filter.pdf
(2.1 Mb)
PDF
You might also like
A PM-Assisted Synchronous Reluctance Motor with Two Slot-Pitch Winding
(2020)
Presentation / Conference Contribution
Analysis of a Five-Phase PM Vernier Machine Topology with Two-Slot Pitch Winding
(2020)
Presentation / Conference Contribution
Analytical Model for Reluctance and Cage Rotor Bar Magnetic Gear
(2020)
Journal Article