Lamia Belguerras
Non-linear circuit based model of PMSM under inter-turn fault: a simple approach based on healthy machine data
Belguerras, Lamia; Arellano-Padilla, Jesus; Arumugam, Puvaneswaran; Hamiti, Tahar; Mezani, Smail; Gerada, C.
Authors
Jesus Arellano-Padilla
Puvaneswaran Arumugam
Tahar Hamiti
Smail Mezani
CHRISTOPHER GERADA CHRIS.GERADA@NOTTINGHAM.AC.UK
Professor of Electrical Machines
Abstract
The paper proposes a fast dynamic mathematical model to evaluate the performances of saturated permanent magnet synchronous machines (PMSM) under stator winding’s inter turn fault. The parameters of the model can be determined using only manufacturer’s data of the healthy machine. Two surface mounted PMSM have been considered to investigate the validity of the proposed approach; with distributed and concentrated winding. It has been shown that the proposed model predicts the fault current with a reasonable accuracy compared to the non-linear Finite Elements analyses and to the experimental results. This model can be incorporated in a global simulation environment of power electronic of electrical device since the computation time is very short.
Citation
Belguerras, L., Arellano-Padilla, J., Arumugam, P., Hamiti, T., Mezani, S., & Gerada, C. (in press). Non-linear circuit based model of PMSM under inter-turn fault: a simple approach based on healthy machine data. IET Electric Power Applications, 10(6), https://doi.org/10.1049/iet-epa.2015.0443
Journal Article Type | Article |
---|---|
Acceptance Date | Feb 23, 2016 |
Online Publication Date | Jun 30, 2016 |
Deposit Date | Aug 22, 2016 |
Publicly Available Date | Aug 22, 2016 |
Journal | IET Electric Power Applications |
Print ISSN | 1751-8660 |
Electronic ISSN | 1751-8679 |
Publisher | Institution of Engineering and Technology (IET) |
Peer Reviewed | Peer Reviewed |
Volume | 10 |
Issue | 6 |
DOI | https://doi.org/10.1049/iet-epa.2015.0443 |
Keywords | Inter-turn fault, finite elements methods, dynamic models, magnetic saturation |
Public URL | https://nottingham-repository.worktribe.com/output/792714 |
Publisher URL | http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7501644 |
Files
Non-linear circuit based model of permanent magnet synchronous machine under interturn fault A simple approach based on healthy machine data.pdf
(1.2 Mb)
PDF
You might also like
Analytical Calculation and Experimental Validation of Litz Wires Axial Thermal Conductivity
(2023)
Journal Article
AC/DC Converter Topologies Comparison for More Electric Aircraft Applications
(2022)
Conference Proceeding
Surface Permanent Magnet Synchronous Machines: High Speed Design and Limits
(2022)
Journal Article
Airgap Length Analysis of a 350kW PM-Assisted Syn-Rel Machine for Heavy Duty EV Traction
(2022)
Journal Article
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: digital-library-support@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search