Abstract

Background:Brain magnetic resonance imaging in patients with cochlear implants (CIs) is impacted by image artefacts.Hypothesis:The optimal positioning of the CI to minimize artefacts is unknown. This study aimed to characterize the dependence of the extent and distribution of the artefact on CI positioning.Methods:Three normally hearing individuals underwent magnetic resonance imaging using a standard T1-weighted 3D sequence. Scans were acquired with a non-functioning CI placed underneath a swimming cap at four plausible scalp positions on each side, and without the CI in situ. The artefact in each image was assessed quantitatively using voxel-based techniques. Two radiologists also independently rated the likely impact of the artefact on the detection of pathology for 20 neuroradiological locations.Results:The procedure was well tolerated. The most postero-inferior CI positions resulted in the smallest apparent artefacts. Radiological evaluations suggested that artefacts would likely limit pathology detection in the ipsilateral temporal, parietal, and occipital lobes, regardless of CI location. Pathology detection in contralateral structures and anterior corpus callosum was rarely affected. Certain CI locations appeared to selectively spare ipsilateral structures, for example, postero-inferior CI locations selectively spared ipsilateral midbrain, deep grey matter, and frontal lobes.Conclusion:A CI placed under a swimming cap is a feasible tool for observing the effect of CI location on image usability within a single subject and potentially informing surgical planning. Regardless of CI placement, artefacts involving ipsilateral parietal, temporal, and occipital lobes severely limited diagnostic image utility. Between 35% and 70% of neuroradiological features were deemed unaffected by the implant.

Citation

Dewey, R. S., Dineen, R. A., Clemence, M., Dick, O., Bowtell, R., & Kitterick, P. T. (2021). Parametric Assessment of the Effect of Cochlear Implant Positioning on Brain MRI Artefacts at 3 T. Otology and Neurotology, 42(10), e1449-e1456. https://doi.org/10.1097/MAO.0000000000003281

Journal Article Type Article
Acceptance Date May 27, 2021
Online Publication Date Jul 9, 2021
Publication Date 2021-12
Deposit Date Jun 2, 2021
Publicly Available Date Jul 10, 2022
Journal Otology and Neurotology
Print ISSN 1531-7129
Electronic ISSN 1537-4505
Publisher Lippincott, Williams & Wilkins
Peer Reviewed Peer Reviewed
Volume 42
Issue 10
Pages e1449-e1456
DOI https://doi.org/10.1097/MAO.0000000000003281
Keywords Neurology (clinical); Sensory Systems; Otorhinolaryngology
Public URL https://nottingham-repository.worktribe.com/output/5367005
Publisher URL https://journals.lww.com/otology-neurotology/Abstract/9000/Parametric_Assessment_of_the_Effect_of_Cochlear.95586.aspx

Files





You might also like



Downloadable Citations