Skip to main content

Research Repository

Advanced Search

Development and validation of a novel fibre-optic respiratory rate sensor (FiRRS) integrated in oxygen delivery devices

Sinha, Rishie; Hernandez, Francisco; He, Chenyang; Korposh, Sergiy; Correia, Ricardo Nuno Goncalves; Norris, Andrew; Liu, Chong; Hayes-Gill, Barrie R.; Morgan, Stephen P.

Development and validation of a novel fibre-optic respiratory rate sensor (FiRRS) integrated in oxygen delivery devices Thumbnail


Authors

Rishie Sinha

Francisco Hernandez

Chenyang He

Profile Image

SERHIY KORPOSH S.Korposh@nottingham.ac.uk
Professor of Photonics Instrumentation

Andrew Norris

CHONG LIU CHONG.LIU1@NOTTINGHAM.AC.UK
Research Fellow

BARRIE HAYES-GILL BARRIE.HAYES-GILL@NOTTINGHAM.AC.UK
Professor of Electronic Systems and Medical Devices



Abstract

© 2021 The Author(s). Respiratory rate (RR) monitoring provides crucial information on the overall health condition of patients and a reliable, low cost RR monitor for normal hospital inpatient or home use would be of significant benefit. The proposed system measures light reflection from a Fibre Bragg Grating (FBG) located near, and the total reflection spectrum from a humidity sensing film deposited at, the tip of an optical fibre. Every breath causes a shift in the wavelength reflected from the FBG and intensity change in the overall reflection spectrum. The accuracy of different techniques is investigated in a two-part study with 15 healthy volunteers. In part 1, the participants' respiration rate followed a handheld mobile application at 5, 12 and 30 breaths per minute with simultaneous measurement using the optical fibre system, thoracic impedance pneumography (TIP) and capnometry device (where possible). Two types of medical face masks and a nasal cannula with oxygen delivery rates were investigated. In part 2, participants wore an anaesthetic face mask and breathed at normal and low tidal volumes to evaluate whether low tidal volumes could be detected. The most accurate measurement of RR was through monitoring the Bragg wavelength shift (mean accuracy = 88.1%), followed by the intensity change at the Bragg wavelength (mean accuracy = 78.9%), capnometry (mean accuracy = 77.8%), area under the overall spectrum (mean accuracy = 65.4%) and TIP (mean accuracy = 43.1%). The Fibre-optic Respiratory Rate Sensor system (FiRRS) can differentiate between normal and low tidal volumes (p-value < 0.05) and demonstrated higher accuracy than capnometry measurement of end-tidal carbon dioxide in exhaled air. These latter two monitors measured RR more accurately than TIP. A comparable accuracy in the measurement of RR was obtained when the FiRRS was implemented in nasal cannula and face masks.

Citation

Sinha, R., Hernandez, F., He, C., Korposh, S., Correia, R. N. G., Norris, A., …Morgan, S. P. (2021). Development and validation of a novel fibre-optic respiratory rate sensor (FiRRS) integrated in oxygen delivery devices. Journal of Physics D: Applied Physics, 54(12), https://doi.org/10.1088/1361-6463/abd061

Journal Article Type Article
Acceptance Date Nov 27, 2020
Online Publication Date Jan 14, 2021
Publication Date Mar 25, 2021
Deposit Date Dec 4, 2020
Publicly Available Date Jan 14, 2021
Journal Journal of Physics D: Applied Physics
Print ISSN 0022-3727
Electronic ISSN 1361-6463
Publisher IOP Publishing
Peer Reviewed Peer Reviewed
Volume 54
Issue 12
Article Number 124002
DOI https://doi.org/10.1088/1361-6463/abd061
Keywords Acoustics and Ultrasonics; Electronic, Optical and Magnetic Materials; Surfaces, Coatings and Films; Condensed Matter Physics
Public URL https://nottingham-repository.worktribe.com/output/5100206
Publisher URL https://iopscience.iop.org/article/10.1088/1361-6463/abd061

Files




You might also like



Downloadable Citations