Skip to main content

Research Repository

Advanced Search

Improved fibre dispersion estimation using b-tensor encoding

Cottaar, Michiel; Szczepankiewicz, Filip; Bastiani, Matteo; Hernandez-Fernandez, Moises; Sotiropoulos, Stamatios N.; Nilsson, Markus; Jbabdi, Saad

Improved fibre dispersion estimation using b-tensor encoding Thumbnail


Authors

Michiel Cottaar

Filip Szczepankiewicz

Matteo Bastiani

Moises Hernandez-Fernandez

Markus Nilsson

Saad Jbabdi



Abstract

© 2020 The Authors Measuring fibre dispersion in white matter with diffusion magnetic resonance imaging (MRI) is limited by an inherent degeneracy between fibre dispersion and microscopic diffusion anisotropy (i.e., the diffusion anisotropy expected for a single fibre orientation). This means that estimates of fibre dispersion rely on strong assumptions, such as constant microscopic anisotropy throughout the white matter or specific biophysical models. Here we present a simple approach for resolving this degeneracy using measurements that combine linear (conventional) and spherical tensor diffusion encoding. To test the accuracy of the fibre dispersion when our microstructural model is only an approximation of the true tissue structure, we simulate multi-compartment data and fit this with a single-compartment model. For such overly simplistic tissue assumptions, we show that the bias in fibre dispersion is greatly reduced (~5x) for single-shell linear and spherical tensor encoding data compared with single-shell or multi-shell conventional data. In in-vivo data we find a consistent estimate of fibre dispersion as we reduce the b-value from 3 to 1.5 ms/μm2, increase the repetition time, increase the echo time, or increase the diffusion time. We conclude that the addition of spherical tensor encoded data to conventional linear tensor encoding data greatly reduces the sensitivity of the estimated fibre dispersion to the model assumptions of the tissue microstructure.

Citation

Cottaar, M., Szczepankiewicz, F., Bastiani, M., Hernandez-Fernandez, M., Sotiropoulos, S. N., Nilsson, M., & Jbabdi, S. (2020). Improved fibre dispersion estimation using b-tensor encoding. NeuroImage, 215, https://doi.org/10.1016/j.neuroimage.2020.116832

Journal Article Type Article
Acceptance Date Apr 6, 2020
Online Publication Date Apr 10, 2020
Publication Date Jul 15, 2020
Deposit Date Apr 8, 2020
Publicly Available Date Apr 10, 2020
Journal NeuroImage
Electronic ISSN 1095-9572
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 215
Article Number 116832
DOI https://doi.org/10.1016/j.neuroimage.2020.116832
Keywords Cognitive Neuroscience; Neurology
Public URL https://nottingham-repository.worktribe.com/output/4270512
Publisher URL https://www.sciencedirect.com/science/article/pii/S1053811920303190

Files






You might also like



Downloadable Citations