Numerical Simulation of a Scanning Illumination System for Deep Tissue Fluorescence Imaging
Zhang, Qimei; Grabowska, Anna M.; Clarke, Philip A.; Morgan, Stephen P.
Authors
Anna M. Grabowska
Philip A. Clarke
Prof STEVE MORGAN STEVE.MORGAN@NOTTINGHAM.AC.UK
Professor of Biomedical Engineering
Abstract
he spatial resolution and light detected in fluorescence imaging for small animals are limited by light scattering, absorption and autofluorescence. To address this, novel near-infrared fluorescent contrast agents and imaging configurations have been investigated. In this paper, the influence of the light wavelength and imaging configurations (full-field illumination system and scanning system) on fluorescence imaging are compared quantitatively. The surface radiance for both systems is calculated by modifying the simulation tool Near-Infrared Fluorescence and Spectral Tomography. Fluorescent targets are embedded within a scattering medium at different positions. The surface radiance and spatial resolution are obtained for emission wavelengths between 620 nm and 1000 nm. It was found that the spatial resolution of the scanning system is independent of the tissue optical properties, whereas for full-field illumination, the spatial resolution degrades at longer wavelength. The full width at half maximum obtained by the scanning system is 25% lower than that obtained by the full-field illumination system when the targets are located in the middle of the phantom. The results indicate that although imaging at near-infrared wavelength can achieve a higher surface radiance, it may produce worse spatial resolution.
Citation
Zhang, Q., Grabowska, A. M., Clarke, P. A., & Morgan, S. P. (2019). Numerical Simulation of a Scanning Illumination System for Deep Tissue Fluorescence Imaging. Journal of Imaging, 5(11), Article 83. https://doi.org/10.3390/jimaging5110083
Journal Article Type | Article |
---|---|
Acceptance Date | Oct 20, 2019 |
Online Publication Date | Oct 24, 2019 |
Publication Date | 2019-11 |
Deposit Date | Oct 25, 2019 |
Publicly Available Date | Oct 25, 2019 |
Journal | Journal of Imaging |
Print ISSN | 2313-433X |
Electronic ISSN | 2313-433X |
Publisher | MDPI |
Peer Reviewed | Peer Reviewed |
Volume | 5 |
Issue | 11 |
Article Number | 83 |
DOI | https://doi.org/10.3390/jimaging5110083 |
Public URL | https://nottingham-repository.worktribe.com/output/2965358 |
Publisher URL | https://www.mdpi.com/2313-433X/5/11/83 |
Contract Date | Oct 25, 2019 |
Files
jimaging-05-00083-v2
(793 Kb)
PDF
Publisher Licence URL
https://creativecommons.org/licenses/by/4.0/
You might also like
Pulse oximeter bench tests under different simulated skin tones
(2024)
Journal Article
Forehead monitoring of heart rate in neonatal intensive care
(2023)
Journal Article
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search