Fetal Heart Rate Analysis in Pregnancies Complicated by Gestational Diabetes Mellitus: A Prospective Multicentre Observational Study (2024)
Journal Article
Chivers, S., Ovadia, C., Vasavan, T., Lucchini, M., Hayes‐Gill, B., Pini, N., Fifer, W. P., & Williamson, C. (2024). Fetal Heart Rate Analysis in Pregnancies Complicated by Gestational Diabetes Mellitus: A Prospective Multicentre Observational Study. BJOG: An International Journal of Obstetrics and Gynaecology, https://doi.org/10.1111/1471-0528.18010

Objective

Establish whether pregnancies complicated by gestational diabetes mellitus (GDM) are associated with a fetal cardiac phenotype that predisposes to arrhythmia; utilising measurements derived from non-invasive abdominal fetal ECG.

Desig... Read More about Fetal Heart Rate Analysis in Pregnancies Complicated by Gestational Diabetes Mellitus: A Prospective Multicentre Observational Study.

Respiratory Rate Monitoring via a Fibre Bragg Grating-Embedded Respirator Mask with a Wearable Miniature Interrogator (2024)
Journal Article
Limweshasin, N., Castro, I. A., Korposh, S., Morgan, S. P., Hayes-Gill, B. R., Faghy, M. A., & Correia, R. (2024). Respiratory Rate Monitoring via a Fibre Bragg Grating-Embedded Respirator Mask with a Wearable Miniature Interrogator. Sensors, 24(23), Article 7476. https://doi.org/10.3390/s24237476

A respiration rate (RR) monitoring system was created by integrating a Fibre Bragg Grating (FBG) optical fibre sensor into a respirator mask. The system exploits the sensitivity of an FBG to temperature to identify an individual’s RR by measuring air... Read More about Respiratory Rate Monitoring via a Fibre Bragg Grating-Embedded Respirator Mask with a Wearable Miniature Interrogator.

Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth (2024)
Journal Article
Swamy, S. K. . N., Stockwell, S. J., Liu, C., Henry, C., Shipley, L., Ward, C., Mirahmadi, S., Correia, R., Morgan, S. P., Crowe, J. A., Sharkey, D., & Hayes-Gill, B. R. (2024). Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth. Pediatric Research, https://doi.org/10.1038/s41390-024-03651-0

Background: To study the feasibility of measuring heart rate (HR) and oxygen saturation (SpO2) on the forehead, during newborn transition at birth, and to compare these measurements with those obtained from the wrist. Methods: Vital signs were measur... Read More about Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth.

Exploring the Bias: How Skin Colour Influences Oxygen Saturation Readings via Monte Carlo Simulations (2024)
Journal Article
Swamy, S., Liu, C., Correia, R., Hayes-Gill, B., & Morgan, S. (2024). Exploring the Bias: How Skin Colour Influences Oxygen Saturation Readings via Monte Carlo Simulations. Journal of Biomedical Optics, 29(S3), Article S33308. https://doi.org/10.1117/1.JBO.29.S3.S33308

Significance: Understanding the root cause of reported oxygen saturation (SpO2) overestimation in heavily pigmented skin types to devise solutions toward enabling equity in pulse oximeter design.

Aim: To gain theoretical insights into the effect o... Read More about Exploring the Bias: How Skin Colour Influences Oxygen Saturation Readings via Monte Carlo Simulations.

Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube cuff leakage testing (2024)
Journal Article
Agbiki, T., Arm, R., Hewson, D. W., Erdody, S., Norris, A. M., Correia, R., Korposh, S., Hayes-Gill, B. R., Shahidi, A., & Morgan, S. P. (2024). Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube cuff leakage testing. BJA Open, 10, Article 100290. https://doi.org/10.1016/j.bjao.2024.100290

Introduction
Leakage of orogastric secretions past the cuff of a tracheal tube is a contributory factor in ventilator-associated pneumonia. Current bench test methods specified in the International Standard for Anaesthetic and Respiratory Equipment... Read More about Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube cuff leakage testing.

Pulse oximeter bench tests under different simulated skin tones (2024)
Journal Article
Swamy, S. K. N., He, C., Hayes‑Gill, B. R., Hayes-Gill, B. R., Clark, D. J., Green, S., & Morgan, S. P. (2024). Pulse oximeter bench tests under different simulated skin tones. Medical and Biological Engineering and Computing, https://doi.org/10.1007/s11517-024-03091-2

Pulse oximeters’ (POs) varying performance based on skin tones has been highly publicised. Compared to arterial blood gas analysis, POs tend to overestimate oxygen saturation (SpO2) values for people with darker skin (occult hypoxemia). The objective... Read More about Pulse oximeter bench tests under different simulated skin tones.

Forehead monitoring of heart rate in neonatal intensive care (2023)
Journal Article
Stockwell, S. J., Kwok, T. C., Morgan, S. P., Sharkey, D., & Hayes-Gill, B. R. (2023). Forehead monitoring of heart rate in neonatal intensive care. Frontiers in Physiology, 14, Article 1127419. https://doi.org/10.3389/fphys.2023.1127419

Heart rate is an extremely important physiological parameter to measure in critically unwell infants, as it is the main physiological marker that changes in response to a change in infant condition. Heart rate is routinely measured peripherally on a... Read More about Forehead monitoring of heart rate in neonatal intensive care.

U-shape functionalized optical fibre sensors for measurement of anaesthetic propofol (2022)
Journal Article
Hernandez, F. U., Wang, T., Lee, S. W., Norris, A., Liu, L. L., Hayes-Gill, B. R., Morgan, S. P., & Korposh, S. (2022). U-shape functionalized optical fibre sensors for measurement of anaesthetic propofol. Sensors and Actuators B: Chemical, 372, Article 132653. https://doi.org/10.1016/j.snb.2022.132653

Propofol is used widely for intravenous anaesthesia during surgery and sedation in critical care. There is no method currently to assay the concentration of propofol in plasma in real time. The ability to do so would significantly improve patient saf... Read More about U-shape functionalized optical fibre sensors for measurement of anaesthetic propofol.

Measurement of the cardiac time intervals of the fetal ECG utilising a computerised algorithm: A retrospective observational study (2022)
Journal Article
Chivers, S., Vasavan, T., Nandi, M., Hayes-Gill, B., Jayawardane, I., Simpson, J., Williamson, C., Fifer, W., & Lucchini, M. (2022). Measurement of the cardiac time intervals of the fetal ECG utilising a computerised algorithm: A retrospective observational study. JRSM Cardiovascular Disease, 11, Article 204800402210962. https://doi.org/10.1177/20480040221096209

.Objective
Establish whether the reliable measurement of cardiac time intervals of the fetal ECG can be automated and to address whether this approach could be used to investigate large datasets.

Design
Retrospective observational study.

Sett... Read More about Measurement of the cardiac time intervals of the fetal ECG utilising a computerised algorithm: A retrospective observational study.