Skip to main content

Research Repository

Advanced Search

Outputs (7)

Designing Optimal Loop, Saddle, and Ellipse-Based Magnetic Coils by Spherical Harmonic Mapping (2023)
Journal Article
Hobson, P. J., Hardwicke, N. L., Davis, A., Smith, T. X., Morley, C., Packer, M., …Fromhold, M. (2023). Designing Optimal Loop, Saddle, and Ellipse-Based Magnetic Coils by Spherical Harmonic Mapping. IEEE Transactions on Instrumentation and Measurement, 72, Article 1005815. https://doi.org/10.1109/TIM.2023.3284138

Adaptable, low-cost, coils designed by carefully selecting the arrangements and geometries of simple primitive units are used to generate magnetic fields for diverse applications. These extend from magnetic resonance and fundamental physics experimen... Read More about Designing Optimal Loop, Saddle, and Ellipse-Based Magnetic Coils by Spherical Harmonic Mapping.

Wireless electrical–molecular quantum signalling for cancer cell apoptosis (2023)
Journal Article
Jain, A., Gosling, J., Liu, S., Wang, H., Stone, E. M., Chakraborty, S., …Rawson, F. J. (2024). Wireless electrical–molecular quantum signalling for cancer cell apoptosis. Nature Nanotechnology, 19, 106-114. https://doi.org/10.1038/s41565-023-01496-y

Quantum biological tunnelling for electron transfer is involved in controlling essential functions for life such as cellular respiration and homoeostasis. Understanding and controlling the quantum effects in biology has the potential to modulate biol... Read More about Wireless electrical–molecular quantum signalling for cancer cell apoptosis.

Benchtop magnetic shielding for benchmarking atomic magnetometers (2023)
Journal Article
Hobson, P. J., Holmes, N., Patel, P., Styles, B., Chalmers, J., Morley, C., …Fromhold, M. (2023). Benchtop magnetic shielding for benchmarking atomic magnetometers. IEEE Transactions on Instrumentation and Measurement, 72, Article 6007309. https://doi.org/10.1109/tim.2023.3293540

Here, a benchtop hybrid magnetic shield containing four mumetal cylinders and nine internal flexible printed circuit boards is designed, constructed, tested, and operated. The shield is designed specifically as a test-bed for building and operating u... Read More about Benchtop magnetic shielding for benchmarking atomic magnetometers.

Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023)
Journal Article
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., …Bowtell, R. (2023). Naturalistic Hyperscanning with Wearable Magnetoencephalography. Sensors, 23(12), Article 5454. https://doi.org/10.3390/s23125454

The evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substra... Read More about Naturalistic Hyperscanning with Wearable Magnetoencephalography.

Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding (2023)
Journal Article
Holmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., …Bowtell, R. (2023). Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding. NeuroImage, 274, Article 120157. https://doi.org/10.1016/j.neuroimage.2023.120157

The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to... Read More about Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding.

Casimir-Polder interactions of S-state Rydberg atoms with graphene (2023)
Journal Article
Wongcharoenbhorn, K., Koller, C., Fromhold, T. M., & Li, W. (2023). Casimir-Polder interactions of S-state Rydberg atoms with graphene. Physical Review A, 107(4), Article 043308. https://doi.org/10.1103/PhysRevA.107.043308

We investigate the thermal Casimir-Polder (CP) potential of 87Rb atoms in Rydberg nS-states near single- and double-layer graphene, and briefly look into the lifetimes near graphene-hexagonal boron nitride (hBN) multilayered structures. The dependenc... Read More about Casimir-Polder interactions of S-state Rydberg atoms with graphene.

Graphene FETs with high and low mobilities have universal temperature-dependent properties (2023)
Journal Article
Gosling, J., Morozov, S. V., Vdovin, E. E., Greenaway, M. T., Khanin, Y. N., Kudrynskyi, Z., …Makarovsky, O. (2023). Graphene FETs with high and low mobilities have universal temperature-dependent properties. Nanotechnology, 34(12), Article 125702. https://doi.org/10.1088/1361-6528/aca981

We use phenomenological modelling and detailed experimental studies of charge carrier transport to investigate the dependence of the electrical resistivity,ρ, on gate voltage,Vg, for a series of monolayer graphene field effect transistors with mobili... Read More about Graphene FETs with high and low mobilities have universal temperature-dependent properties.