Skip to main content

Research Repository

Advanced Search

All Outputs (22)

Parameter control in synthesis of Vermiculite-CaCl2 composite materials for thermochemical adsorption heat storage (2024)
Journal Article
Zhang, Y., Chen, Z., Zhang, Y., Su, Y., & Riffat, S. (2024). Parameter control in synthesis of Vermiculite-CaCl2 composite materials for thermochemical adsorption heat storage. Energy, 291, Article 130478. https://doi.org/10.1016/j.energy.2024.130478

This study utilised vermiculite as a matrix to explore various impregnation methods for synthesising vermiculite-CaCl2 composite materials (VCMs), focusing on the impact of these methods on the performance of VCMs as thermochemical materials. Results... Read More about Parameter control in synthesis of Vermiculite-CaCl2 composite materials for thermochemical adsorption heat storage.

Performance study of a thermochemical energy storage reactor embedded with a microchannel tube heat exchanger for water heating (2023)
Journal Article
Zhang, Y., Hu, M., Chen, Z., Su, Y., & Riffat, S. (2024). Performance study of a thermochemical energy storage reactor embedded with a microchannel tube heat exchanger for water heating. Journal of Energy Storage, 78, Article 110043. https://doi.org/10.1016/j.est.2023.110043

Thermochemical energy storage (TCES) provides a promising solution to addressing the mismatch between solar thermal production and heating demands in buildings. However, existing air-based open TCES systems face practical challenges in integrating wi... Read More about Performance study of a thermochemical energy storage reactor embedded with a microchannel tube heat exchanger for water heating.

Exploring a novel tubular-type modular reactor for solar-driven thermochemical energy storage (2023)
Journal Article
Zhang, Y., Hu, M., Chen, Z., Su, Y., & Riffat, S. (2024). Exploring a novel tubular-type modular reactor for solar-driven thermochemical energy storage. Renewable Energy, 221, Article 119767. https://doi.org/10.1016/j.renene.2023.119767

Thermochemical energy storage (TCES) has gained extensive attention as a potential solution to address the mismatch between solar thermal energy production and demand. In this study, a novel tubular-type modular TCES reactor is introduced. COMSOL mod... Read More about Exploring a novel tubular-type modular reactor for solar-driven thermochemical energy storage.

COALAS II. Extended molecular gas reservoirs are common in a distant, forming galaxy cluster (2023)
Journal Article
Chen, Z., Dannerbauer, H., Lehnert, M., Emonts, B. H. C., Gu, Q., Allison, J. R., …Ziegler, B. (2024). COALAS II. Extended molecular gas reservoirs are common in a distant, forming galaxy cluster. Monthly Notices of the Royal Astronomical Society, 527(3), 8950–8972. https://doi.org/10.1093/mnras/stad3128

This paper presents the results of 475 hours of interferometric observations with the Australia Telescope Compact Array towards the Spiderweb protocluster at (z=2.16). We search for large, extended molecular gas reservoirs among 46 previously detecte... Read More about COALAS II. Extended molecular gas reservoirs are common in a distant, forming galaxy cluster.

Antiviral activity of salt-coated materials against SARS-CoV-2 (2023)
Journal Article
Coleman, C. M., Wang, B., Wang, Y., Tapia-Brito, E., Chen, Z., Riffat, J., Riffat, S., Tarlinton, R., & Ghaemmaghami, A. (2023). Antiviral activity of salt-coated materials against SARS-CoV-2. Access Microbiology, 5(9), Article 000492. https://doi.org/10.1099/acmi.0.000492.v5

The SARS-CoV-2 pandemic demonstrated the importance of human coronaviruses and the need to develop materials to prevent the spread of emergent respiratory viruses. Coating of surfaces with antiviral materials is a major interest in controlling spread... Read More about Antiviral activity of salt-coated materials against SARS-CoV-2.

A study on vermiculite-based salt mixture composite materials for low-grade thermochemical adsorption heat storage (2023)
Journal Article
Chen, Z., Zhang, Y., Zhang, Y., Su, Y., & Riffat, S. (2023). A study on vermiculite-based salt mixture composite materials for low-grade thermochemical adsorption heat storage. Energy, 278(Part B), Article 127986. https://doi.org/10.1016/j.energy.2023.127986

High-performance renewable energy technologies are desired to meet the enormous demand during the clean energy transition. Thermal energy storage can help balance the mismatch between renewable energy supplies and end-user's demands. Thermochemical a... Read More about A study on vermiculite-based salt mixture composite materials for low-grade thermochemical adsorption heat storage.

Antiviral activity of salt-coated materials against SARS-CoV-2. (2023)
Preprint / Working Paper
Coleman, C. M., Wang, B., Wang, Y., Tapia-Brito, E., Chen, Z., Riffat, J., Riffat, S., Tarlinton, R., & Ghaemmaghami, A. Antiviral activity of salt-coated materials against SARS-CoV-2

The SARS-CoV-2 pandemic demonstrated the importance of human coronaviruses and the need to develop materials to prevent the spread of emergent viruses. Here we describe that simple salt coating on a range of surfaces can degrade SARS-CoV-2.

Modelling analysis of a solar-driven thermochemical energy storage unit combined with heat recovery (2023)
Journal Article
Zhang, Y., Hu, M., Chen, Z., Su, Y., & Riffat, S. (2023). Modelling analysis of a solar-driven thermochemical energy storage unit combined with heat recovery. Renewable Energy, 206, 722-737. https://doi.org/10.1016/j.renene.2023.02.076

Solar-driven thermochemical energy storage (TCES) can address the mismatch between solar heat production and heating demand and contribute to decarbonisation in buildings. In many studies of typical salt hydrate TCES systems, massive heat carried by... Read More about Modelling analysis of a solar-driven thermochemical energy storage unit combined with heat recovery.

Signs of environmental effects on star-forming galaxies in the Spiderweb protocluster at z = 2.16 (2022)
Journal Article
Pérez-Martínez, J. M., Dannerbauer, H., Kodama, T., Koyama, Y., Shimakawa, R., Suzuki, T. L., …Tanaka, I. (2023). Signs of environmental effects on star-forming galaxies in the Spiderweb protocluster at z = 2.16. Monthly Notices of the Royal Astronomical Society, 518(2), 1707-1734. https://doi.org/10.1093/mnras/stac2784

We use multi-object near-infrared spectroscopy with VLT/KMOS to investigate the role of the environment in the evolution of the ionized gas properties of narrow-band-selected H α emitters (HAEs) in the Spiderweb protocluster at z = 2.16. Based on res... Read More about Signs of environmental effects on star-forming galaxies in the Spiderweb protocluster at z = 2.16.

Investigation on a Vermiculite-Based Solar Thermochemical Heat Storage System for Building Applications (2022)
Journal Article
Zhang, Y., Chen, Z., Kutlu, C., Su, Y., & Riffat, S. (2022). Investigation on a Vermiculite-Based Solar Thermochemical Heat Storage System for Building Applications. Future Cities and Environment, 8(1), 1-14. https://doi.org/10.5334/fce.153

Industrial processes and the building sector (e.g., for space and water heating) are responsible for the majority of the total energy consumed for heat. Although fossil fuels remain to dominate the heating sector, renewable heating technologies have... Read More about Investigation on a Vermiculite-Based Solar Thermochemical Heat Storage System for Building Applications.

Experimental study of liquid to air membrane energy exchanger (LAMEE) performance by measuring its temperature fields (2019)
Journal Article
Chu, J., Chen, Z., Bai, H., & Zhu, J. (2019). Experimental study of liquid to air membrane energy exchanger (LAMEE) performance by measuring its temperature fields. Thermal Science and Engineering Progress, 10, 163-168. https://doi.org/10.1016/j.tsep.2019.01.005

Many studies have already been conducted to assess liquid to air membrane energy exchanger (LAMEE) performance by numerical and experimental methods. However, the LAMEE temperature field is still an unknown area due to the operation difficult. In thi... Read More about Experimental study of liquid to air membrane energy exchanger (LAMEE) performance by measuring its temperature fields.

Performance evaluation of a membrane-based flat-plate heat and mass exchanger used for liquid desiccant regeneration (2018)
Journal Article
Bai, H., Zhu, J., Chen, Z., Chu, J., & Liu, Y. (2018). Performance evaluation of a membrane-based flat-plate heat and mass exchanger used for liquid desiccant regeneration. Applied Thermal Engineering, 139, https://doi.org/10.1016/j.applthermaleng.2018.05.011

Liquid desiccant dehumidification system has gained much progress recently for its considerable energy saving potential without liquid water condensation. Within the system, regeneration is of great importance since diluted desiccant solution after d... Read More about Performance evaluation of a membrane-based flat-plate heat and mass exchanger used for liquid desiccant regeneration.

State-of-art in modelling methods of membrane-based liquid desiccant heat and mass exchanger: a comprehensive review (2018)
Journal Article
Bai, H., Zhu, J., Chen, Z., & Chu, J. (2018). State-of-art in modelling methods of membrane-based liquid desiccant heat and mass exchanger: a comprehensive review. International Journal of Heat and Mass Transfer, 125, https://doi.org/10.1016/j.ijheatmasstransfer.2018.04.100

Air dehumidification is of vital importance in building air conditioning and production safety. Semi-permeable membrane module is a novel heat and mass exchanger, which separates the air and liquid desiccant to overcome desiccant droplet carry-over p... Read More about State-of-art in modelling methods of membrane-based liquid desiccant heat and mass exchanger: a comprehensive review.

Optical design of compact linear Fresnel reflector systems (2017)
Journal Article
Zhu, J., & Chen, Z. (in press). Optical design of compact linear Fresnel reflector systems. Solar Energy Materials and Solar Cells, 176, https://doi.org/10.1016/j.solmat.2017.12.016

Compact linear Fresnel reflector (CLFR) system employing multiple receivers is promising with better optical performance and cost effectiveness compared to linear Fresnel reflector (LFR) system, especially for applications with limited ground availab... Read More about Optical design of compact linear Fresnel reflector systems.

Parametric analysis of a cross-flow membrane-based parallel-plate liquid desiccant dehumidification system: numerical and experimental data (2017)
Journal Article
Bai, H., Zhu, J., Chen, Z., & Chu, J. (2018). Parametric analysis of a cross-flow membrane-based parallel-plate liquid desiccant dehumidification system: numerical and experimental data. Energy and Buildings, 158, https://doi.org/10.1016/j.enbuild.2017.10.018

Operating parameters of a membrane-based parallel-plate liquid desiccant dehumidification system are investigated in this paper. The liquid desiccant and air are in a cross-flow arrangement, and separated by semi-permeable membranes to avoid carry-ov... Read More about Parametric analysis of a cross-flow membrane-based parallel-plate liquid desiccant dehumidification system: numerical and experimental data.

Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system (2017)
Journal Article
Bai, H., Zhu, J., Chen, Z., Ma, L., Wang, R., & Li, T. (2017). Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system. Applied Thermal Engineering, 119, https://doi.org/10.1016/j.applthermaleng.2017.03.058

A membrane-based liquid desiccant dehumidification system is one of high energy efficient dehumidification approaches, which allows heat and moisture transfers between air stream and desiccant solution without carryover problem. The system performanc... Read More about Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system.

Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations (2017)
Journal Article
Chen, Z., Zhu, J., & Bai, H. (2017). Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations. Energy and Buildings, 139, https://doi.org/10.1016/j.enbuild.2017.01.046

A membrane-based liquid desiccant dehumidification cooling system is studied in this paper for energy efficient air conditioning with independent temperature and humidity controls. The system mainly consists of a dehumidifier, a regenerator, an evapo... Read More about Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations.

Experimental study of a membrane-based dehumidification cooling system (2016)
Journal Article
Chen, Z., Zhu, J., Bai, H., Yan, Y., & Zhang, L. (2017). Experimental study of a membrane-based dehumidification cooling system. Applied Thermal Engineering, 115, https://doi.org/10.1016/j.applthermaleng.2016.10.153

Membrane-based liquid desiccant dehumidification has attracted increasing interests with elimination of solution droplets carryover problem. In this study, a membrane-based hybrid liquid desiccant dehumidification cooling system is developed, which i... Read More about Experimental study of a membrane-based dehumidification cooling system.

Theoretical analysis of a membrane-based cross-flow liquid desiccant system (2016)
Presentation / Conference Contribution
Bai, H., Chen, Z., Xu, H., & Zhu, J. (2016). Theoretical analysis of a membrane-based cross-flow liquid desiccant system.

Liquid desiccant air dehumidification has become one of the most widely used dehumidification technologies with advantages of high efficiency, no liquid condensate droplets and capability of energy storage. In this paper a cross-flow mathematical mod... Read More about Theoretical analysis of a membrane-based cross-flow liquid desiccant system.

Effect of resistive load on the performance of an organic Rankine cycle with a scroll expander (2016)
Journal Article
Zhua, J., Chen, Z., Huang, H., & Yan, Y. (2016). Effect of resistive load on the performance of an organic Rankine cycle with a scroll expander. Energy, 95, https://doi.org/10.1016/j.energy.2015.11.048

An experimental investigation is performed for an organic Rankine cycle system with different electrical resistive loads. The test rig is set up with a small scroll expander-generator unit, a boiler and a magnetically coupled pump. R134a is used as t... Read More about Effect of resistive load on the performance of an organic Rankine cycle with a scroll expander.