Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube cuff leakage testing (2024)
Journal Article
Agbiki, T., Arm, R., Hewson, D. W., Erdody, S., Norris, A. M., Correia, R., …Morgan, S. P. (2024). Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube cuff leakage testing. BJA Open, 10, Article 100290. https://doi.org/10.1016/j.bjao.2024.100290

Introduction
Leakage of orogastric secretions past the cuff of a tracheal tube is a contributory factor in ventilator-associated pneumonia. Current bench test methods specified in the International Standard for Anaesthetic and Respiratory Equipment... Read More about Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube cuff leakage testing.

Highly sensitive optical fibre Bragg grating contact pressure sensor embedded in a polymer layer: modelling and experimental validation (2024)
Journal Article
Abeywardena, C., Zhang, Q., Korposh, S., Morgan, S., Bull, S., & Correia, R. (2024). Highly sensitive optical fibre Bragg grating contact pressure sensor embedded in a polymer layer: modelling and experimental validation. Results in Optics, 14, Article 100604. https://doi.org/10.1016/j.rio.2024.100604

This paper discusses mathematical modelling and experimental validation of a highly sensitive optical fibre Bragg grating (FBG) contact pressure sensor developed for healthcare applications. Bare FBGs are not very sensitive to pressure (~ 3x10-3 nm/M... Read More about Highly sensitive optical fibre Bragg grating contact pressure sensor embedded in a polymer layer: modelling and experimental validation.

Long Period Grating Mach–Zehnder Interferometer Based Immunosensor with Temperature and Bulk Refractive Index Compensation (2022)
Journal Article
Wu, P., Liu, L., Morgan, S. P., Correia, R., & Korposh, S. (2022). Long Period Grating Mach–Zehnder Interferometer Based Immunosensor with Temperature and Bulk Refractive Index Compensation. Biosensors, 12(12), Article 1099. https://doi.org/10.3390/bios12121099

A long period grating Mach–Zehnder interferometer (LPGMZI) that consists of two identical long period gratings (LPGs) in a single fibre was developed to measure immunoglobulin M (IgM). The measured spectrum has fringes due to the interference between... Read More about Long Period Grating Mach–Zehnder Interferometer Based Immunosensor with Temperature and Bulk Refractive Index Compensation.

U-shape functionalized optical fibre sensors for measurement of anaesthetic propofol (2022)
Journal Article
Hernandez, F. U., Wang, T., Lee, S. W., Norris, A., Liu, L. L., Hayes-Gill, B. R., …Korposh, S. (2022). U-shape functionalized optical fibre sensors for measurement of anaesthetic propofol. Sensors and Actuators B: Chemical, 372, Article 132653. https://doi.org/10.1016/j.snb.2022.132653

Propofol is used widely for intravenous anaesthesia during surgery and sedation in critical care. There is no method currently to assay the concentration of propofol in plasma in real time. The ability to do so would significantly improve patient saf... Read More about U-shape functionalized optical fibre sensors for measurement of anaesthetic propofol.

Fibre Bragg Grating Based Interface Pressure Sensor for Compression Therapy (2022)
Journal Article
Bradbury, J. A., Zhang, Q., Hernandez Ledezma, F. U., Correia, R., Korposh, S., Hayes-Gill, B. R., …Morgan, S. P. (2022). Fibre Bragg Grating Based Interface Pressure Sensor for Compression Therapy. Sensors, 22(5), Article 1798. https://doi.org/10.3390/s22051798

Compression therapy is widely used as the gold standard for management of chronic venous insufficiency and venous leg ulcers, and the amount of pressure applied during the compression therapy is crucial in supporting healing. A fibre optic pressure s... Read More about Fibre Bragg Grating Based Interface Pressure Sensor for Compression Therapy.

Intra-tracheal multiplexed sensing of contact pressure and perfusion (2021)
Journal Article
Correia, R., Gadsby, B., Korposh, S., Norris, A. M., Hayes-Gill, B. R., Sinha, R., …Morgan, S. P. (2022). Intra-tracheal multiplexed sensing of contact pressure and perfusion. Biomedical Optics Express, 13(1), 48-64. https://doi.org/10.1364/BOE.442165

Incorrect endotracheal tube (ETT) cuff inflation pressure causes significant problems for intubated patients. The technical development and first in vivo use of a smart ETT for measurements at the cuff-trachea interface during mechanical ventilation... Read More about Intra-tracheal multiplexed sensing of contact pressure and perfusion.

Fabrication of Humidity-Resistant Optical Fiber Sensor for Ammonia Sensing Using Diazo Resin-Photocrosslinked Films with a Porphyrin-Polystyrene Binary Mixture (2021)
Journal Article
Ahmed, S., Park, Y., Okuda, H., Ono, S., Korposh, S., & Lee, S.-W. (2021). Fabrication of Humidity-Resistant Optical Fiber Sensor for Ammonia Sensing Using Diazo Resin-Photocrosslinked Films with a Porphyrin-Polystyrene Binary Mixture. Sensors, 21(18), Article 6176. https://doi.org/10.3390/s21186176

Ammonia gas sensors were fabricated via layer-by-layer (LbL) deposition of diazo resin (DAR) and a binary mixture of tetrakis(4-sulfophenyl)porphine (TSPP) and poly(styrene sulfonate) (PSS) onto the core of a multimode U-bent optical fiber. The penet... Read More about Fabrication of Humidity-Resistant Optical Fiber Sensor for Ammonia Sensing Using Diazo Resin-Photocrosslinked Films with a Porphyrin-Polystyrene Binary Mixture.

Optical Fibre Sensor for Capillary Refill Time and Contact Pressure Measurements under the Foot (2021)
Journal Article
Ballaji, H. K., Correia, R., Liu, C., Korposh, S., Hayes-Gill, B. R., Musgrove, A., & Morgan, S. P. (2021). Optical Fibre Sensor for Capillary Refill Time and Contact Pressure Measurements under the Foot. Sensors, 21(18), Article 6072. https://doi.org/10.3390/s21186072

Capillary refill time (CRT) refers to the time taken for body tissue to regain its colour after an applied blanching pressure is released. Usually, pressure is manually applied and not measured. Upon release of pressure, simple mental counting is typ... Read More about Optical Fibre Sensor for Capillary Refill Time and Contact Pressure Measurements under the Foot.

Optical fibre Sensor for Simultaneous Temperature and Relative Humidity Measurement: Towards Absolute Humidity Evaluation (2021)
Journal Article
He, C., Korposh, S., Correia, R., Liu, L., Hayes-Gill, B. R., & Morgan, S. P. (2021). Optical fibre Sensor for Simultaneous Temperature and Relative Humidity Measurement: Towards Absolute Humidity Evaluation. Sensors and Actuators B: Chemical, 344, Article 130154. https://doi.org/10.1016/j.snb.2021.130154

Temperature and humidity are essential parameters in monitoring the health of patients in critical care. An optical fibre sensor has been developed for simultaneous measurement of relative humidity (RH) and temperature at a single optical fibre tip b... Read More about Optical fibre Sensor for Simultaneous Temperature and Relative Humidity Measurement: Towards Absolute Humidity Evaluation.

Carboxyl-fentanyl detection using optical fibre grating-based sensors functionalised with molecularly imprinted nanoparticles (2021)
Journal Article
Liu, L. L., Grillo, F., Canfarotta, F., Whitcombe, M., Morgan, S. P., Piletsky, S., …Korposh, S. (2021). Carboxyl-fentanyl detection using optical fibre grating-based sensors functionalised with molecularly imprinted nanoparticles. Biosensors and Bioelectronics, 177, Article 113002. https://doi.org/10.1016/j.bios.2021.113002

Butyrylfentanyl is a new designer drug reported with growing use and related deaths. Routine toxicological analyses of this novel synthetic opioid drug have not been established yet. This work reports a fibre optic sensor that measures carboxyl-fenta... Read More about Carboxyl-fentanyl detection using optical fibre grating-based sensors functionalised with molecularly imprinted nanoparticles.

Development and validation of a novel fibre-optic respiratory rate sensor (FiRRS) integrated in oxygen delivery devices (2021)
Journal Article
Sinha, R., Hernandez, F., He, C., Korposh, S., Correia, R. N. G., Norris, A., …Morgan, S. P. (2021). Development and validation of a novel fibre-optic respiratory rate sensor (FiRRS) integrated in oxygen delivery devices. Journal of Physics D: Applied Physics, 54(12), Article 124002. https://doi.org/10.1088/1361-6463/abd061

© 2021 The Author(s). Respiratory rate (RR) monitoring provides crucial information on the overall health condition of patients and a reliable, low cost RR monitor for normal hospital inpatient or home use would be of significant benefit. The propose... Read More about Development and validation of a novel fibre-optic respiratory rate sensor (FiRRS) integrated in oxygen delivery devices.

A Textile Sleeve for Monitoring Oxygen Saturation Using Multichannel Optical Fibre Photoplethysmography (2020)
Journal Article
Ballaji, H. K., Correia, R., Korposh, S., Hayes-Gill, B. R., Hernandez, F. U., Salisbury, B., & Morgan, S. P. (2020). A Textile Sleeve for Monitoring Oxygen Saturation Using Multichannel Optical Fibre Photoplethysmography. Sensors, 20(22), Article 6568. https://doi.org/10.3390/s20226568

Textile-based systems are an attractive prospect for wearable technology as they can provide monitoring of key physiological parameters in a comfortable and unobtrusive form. A novel system based on multichannel optical fibre sensor probes integrated... Read More about A Textile Sleeve for Monitoring Oxygen Saturation Using Multichannel Optical Fibre Photoplethysmography.

Real-Time Humidity Measurement during Sports Activity using Optical Fibre Sensing (2020)
Journal Article
He, C., Korposh, S., Hernandez, F. U., Liu, L., Correia, R., Hayes-Gill, B. R., & Morgan, S. P. (2020). Real-Time Humidity Measurement during Sports Activity using Optical Fibre Sensing. Sensors, 20(7), Article 1904. https://doi.org/10.3390/s20071904

An optical fibre sensor for monitoring relative humidity (RH) changes during exercise is demonstrated. The humidity sensor comprises a tip coating of poly (allylamine hydrochloride) (PAH)/silica nanoparticles (SiO2 NPs) deposited using the layer-by-l... Read More about Real-Time Humidity Measurement during Sports Activity using Optical Fibre Sensing.

Optical fibre sensor for simultaneous measurement of capillary refill time and contact pressure (2020)
Journal Article
Liu, C., Correia, R., Ballaji, H., Korposh, S., Hayes‐gill, B., & Morgan, S. (2020). Optical fibre sensor for simultaneous measurement of capillary refill time and contact pressure. Sensors, 20(5), Article 1388. https://doi.org/10.3390/s20051388

© 2020 by the authors. Licensee MDPI, Basel, Switzerland. The widely applied capillary refill time (CRT) measurement is currently performed by manually applying pressure and using a stopwatch to record the time taken for the skin to recover its norma... Read More about Optical fibre sensor for simultaneous measurement of capillary refill time and contact pressure.

Tapered optical fibre sensors: current trends and future perspectives (2019)
Journal Article
Korposh, S., James, S. W., Lee, S., & Tatam, R. P. (2019). Tapered optical fibre sensors: current trends and future perspectives. Sensors, 19(10), Article 2294. https://doi.org/10.3390/s19102294

The development of reliable, affordable and efficient sensors is a key step in providing tools for efficient monitoring of critical environmental parameters. This review focuses on the use of tapered optical fibres as an environmental sensing platfor... Read More about Tapered optical fibre sensors: current trends and future perspectives.

Biomedical application of optical fibre sensors (2018)
Journal Article
Correia, R., James, S., Lee, S.-W., Morgan, S., & Korposh, S. (2018). Biomedical application of optical fibre sensors. Journal of Optics, 20(7), Article 073003. https://doi.org/10.1088/2040-8986/aac68d

Optical fibre sensors(OFS), as a result of their unique properties such as small size, no interference with electromagnetic radiation, high sensitivity and the ability to design multiplexed or distributed sensing systems, have found applications rang... Read More about Biomedical application of optical fibre sensors.

All-optical switching based on optical fibre long period gratings modified bacteriorhodopsin (2017)
Journal Article
Korposh, S., James, S., Partridge, M., Sichka, M., & Tatam, R. (in press). All-optical switching based on optical fibre long period gratings modified bacteriorhodopsin. Optics and Laser Technology, 101, https://doi.org/10.1016/j.optlastec.2017.11.021

All-optical switching using an optical fibre long-period gating (LPG) modified with bacteriorhodopsin (bR) is demonstrated. The switching process is based on the photo-induced RI change of bR, which in turn changes the phase matching conditions of th... Read More about All-optical switching based on optical fibre long period gratings modified bacteriorhodopsin.

Polymeric optical fibre sensor coated by SiO2 nanoparticles for humidity sensing in the skin microenvironment (2017)
Journal Article
Gomez, D., Morgan, S. P., Hayes-Gill, B. R., Correia, R., & Korposh, S. (2018). Polymeric optical fibre sensor coated by SiO2 nanoparticles for humidity sensing in the skin microenvironment. Sensors and Actuators B: Chemical, 254, 887-895. https://doi.org/10.1016/j.snb.2017.07.191

The sensitivity of a low-cost polymeric optical fibre humidity sensor based on transmittance changes due to evanescent wave absorption is reported using test measurements in an environmental chamber and of the skin. The layer-by-layer method was used... Read More about Polymeric optical fibre sensor coated by SiO2 nanoparticles for humidity sensing in the skin microenvironment.

Polymeric fibre optic sensor based on a SiO2 nanoparticle film for humidity sensing on wounds (2016)
Presentation / Conference Contribution
Gomez, D., Morgan, S. P., Hayes Gill, B. R., & Korposh, S. (2016). Polymeric fibre optic sensor based on a SiO2 nanoparticle film for humidity sensing on wounds. Proceedings of SPIE, 9916, Article 991623. https://doi.org/10.1117/12.2236845

© 2016 SPIE. Optical fibre sensors have the potential to be incorporated into wound dressings to monitor moisture and predict healing without the need to remove the dressing. A low cost polymeric optical fibre humidity sensor based on evanescent wave... Read More about Polymeric fibre optic sensor based on a SiO2 nanoparticle film for humidity sensing on wounds.