CFD assessment of multiple energy piles for ground source heat pump in heating mode

Cui, Yuanlong; Zhu, Jie

CFD assessment of multiple energy piles for ground source heat pump in heating mode Thumbnail


Authors

Yuanlong Cui



Abstract

Three-dimensional (3D) computational fluid dynamics (CFD) model of ground source heat pump (GSHP) with multiple energy piles (EPs) is developed to investigate the system heating performances under continuous and intermittent operating conditions, the system thermal energy outputs and coefficients of performance (COPs) are evaluated. The 3D model is meshed based on the hybrid grids with tetrahedron, hexahedron unstructured and structured types, and the k-ε equations to describe the turbulence phenomena within U-tube are resolved by using computational fluid dynamics (CFD) software. A good agreement with less than 12% difference between the CFD model and experimental results is achieved. 10 h active and 14 h idle mode is adopted as the intermittent operating condition in this study. Based on the 3D model simulation data, it is found that the average monthly COPs of the intermittent operation are 3.63, 3.58, 14 3.45, 3.21, 3.25 and 3.34 from November to April respectively, which are corresponding to 9.3%, 9.5%, 7.1%, 5.9%, 4.8% and 3.1% increases relative to those of the continuous operation. Furthermore, the soil temperature under the intermittent operating condition is higher than that of the continuous operation. To sum up, the intermittent operation not only contributes to the soil temperature recovery but also improves the system performance, which is very favourable for the long-term operation.

Citation

Cui, Y., & Zhu, J. (2018). CFD assessment of multiple energy piles for ground source heat pump in heating mode. Applied Thermal Engineering, 139, https://doi.org/10.1016/j.applthermaleng.2018.04.073

Journal Article Type Article
Acceptance Date Apr 15, 2018
Online Publication Date Apr 17, 2018
Publication Date Jul 5, 2018
Deposit Date Apr 16, 2018
Publicly Available Date Apr 18, 2019
Journal Applied Thermal Engineering
Print ISSN 1359-4311
Electronic ISSN 1873-5606
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 139
DOI https://doi.org/10.1016/j.applthermaleng.2018.04.073
Keywords Energy piles; Ground heat exchangers; CFD model; Continuous operation; Intermittent operation