Yuanlong Cui
CFD assessment of multiple energy piles for ground source heat pump in heating mode
Cui, Yuanlong; Zhu, Jie
Abstract
Three-dimensional (3D) computational fluid dynamics (CFD) model of ground source heat pump (GSHP) with multiple energy piles (EPs) is developed to investigate the system heating performances under continuous and intermittent operating conditions, the system thermal energy outputs and coefficients of performance (COPs) are evaluated. The 3D model is meshed based on the hybrid grids with tetrahedron, hexahedron unstructured and structured types, and the k-ε equations to describe the turbulence phenomena within U-tube are resolved by using computational fluid dynamics (CFD) software. A good agreement with less than 12% difference between the CFD model and experimental results is achieved. 10 h active and 14 h idle mode is adopted as the intermittent operating condition in this study. Based on the 3D model simulation data, it is found that the average monthly COPs of the intermittent operation are 3.63, 3.58, 14 3.45, 3.21, 3.25 and 3.34 from November to April respectively, which are corresponding to 9.3%, 9.5%, 7.1%, 5.9%, 4.8% and 3.1% increases relative to those of the continuous operation. Furthermore, the soil temperature under the intermittent operating condition is higher than that of the continuous operation. To sum up, the intermittent operation not only contributes to the soil temperature recovery but also improves the system performance, which is very favourable for the long-term operation.
Citation
Cui, Y., & Zhu, J. (2018). CFD assessment of multiple energy piles for ground source heat pump in heating mode. Applied Thermal Engineering, 139, https://doi.org/10.1016/j.applthermaleng.2018.04.073
Journal Article Type | Article |
---|---|
Acceptance Date | Apr 15, 2018 |
Online Publication Date | Apr 17, 2018 |
Publication Date | Jul 5, 2018 |
Deposit Date | Apr 16, 2018 |
Publicly Available Date | Apr 18, 2019 |
Journal | Applied Thermal Engineering |
Print ISSN | 1359-4311 |
Electronic ISSN | 1873-5606 |
Publisher | Elsevier |
Peer Reviewed | Peer Reviewed |
Volume | 139 |
DOI | https://doi.org/10.1016/j.applthermaleng.2018.04.073 |
Keywords | Energy piles; Ground heat exchangers; CFD model; Continuous operation; Intermittent operation |
Public URL | https://nottingham-repository.worktribe.com/output/944958 |
Publisher URL | https://www.sciencedirect.com/science/article/pii/S1359431118314364?via%3Dihub |
Contract Date | Apr 16, 2018 |
Files
CFD CY09 090418.pdf
(2.2 Mb)
PDF
Copyright Statement
Copyright information regarding this work can be found at the following address: http://creativecommons.org/licenses/by-nc-nd/4.0
You might also like
Aerodynamic design and optimization of sCO2 turbomachinery: Two-Stage optimization approach
(2023)
Journal Article
Energy and Stochastic Economic Assessments of Photovoltaic Systems in the East Midlands
(2023)
Journal Article
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search