Skip to main content

Research Repository

Advanced Search

Incorporating outlier detection and replacement into a non-parametric framework for movement and distortion correction of diffusion MR images

Andersson, Jesper L.R.; Graham, Mark S.; Zsoldos, Enik?; Sotiropoulos, Stamatios N.

Incorporating outlier detection and replacement into a non-parametric framework for movement and distortion correction of diffusion MR images Thumbnail


Authors

Jesper L.R. Andersson

Mark S. Graham

Enik? Zsoldos



Abstract

Despite its great potential in studying brain anatomy and structure, diffusion magnetic resonance imaging (dMRI) is marred by artefacts more than any other commonly used MRI technique. In this paper we present a non-parametric framework for detecting and correcting dMRI outliers (signal loss) caused by subject motion.

Signal loss (dropout) affecting a whole slice, or a large connected region of a slice, is frequently observed in diffusion weighted images, leading to a set of unusable measurements. This is caused by bulk (subject or physiological) motion during the diffusion encoding part of the imaging sequence. We suggest a method to detect slices affected by signal loss and replace them by a non-parametric prediction, in order to minimise their impact on subsequent analysis. The outlier detection and replacement, as well as correction of other dMRI distortions (susceptibility-induced distortions, eddy currents (EC) and subject motion) are performed within a single framework, allowing the use of an integrated approach for distortion correction. Highly realistic simulations have been used to evaluate the method with respect to its ability to detect outliers (types 1 and 2 errors), the impact of outliers on retrospective correction of movement and distortion and the impact on estimation of commonly used diffusion tensor metrics, such as fractional anisotropy (FA) and mean diffusivity (MD). Data from a large imaging project studying older adults (the Whitehall Imaging sub-study) was used to demonstrate the utility of the method when applied to datasets with severe subject movement.

The results indicate high sensitivity and specificity for detecting outliers and that their deleterious effects on FA and MD can be almost completely corrected.

Citation

Andersson, J. L., Graham, M. S., Zsoldos, E., & Sotiropoulos, S. N. (2016). Incorporating outlier detection and replacement into a non-parametric framework for movement and distortion correction of diffusion MR images. NeuroImage, 141, https://doi.org/10.1016/j.neuroimage.2016.06.058

Journal Article Type Article
Acceptance Date Jun 30, 2016
Online Publication Date Jul 5, 2016
Publication Date Nov 1, 2016
Deposit Date Apr 5, 2018
Publicly Available Date Apr 5, 2018
Journal NeuroImage
Print ISSN 1053-8119
Electronic ISSN 1095-9572
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 141
DOI https://doi.org/10.1016/j.neuroimage.2016.06.058
Keywords Diffusion; Movement; Signal loss; Outlier; Registration
Public URL https://nottingham-repository.worktribe.com/output/819688
Publisher URL https://www.sciencedirect.com/science/article/pii/S1053811916303068

Files





You might also like



Downloadable Citations