Partial volume correction in arterial spin labeling perfusion MRI: A method to disentangle anatomy from physiology or an analysis step too far?

Chappell, Michael A.; McConnell, Flora A. Kennedy; Golay, Xavier; Günther, Matthias; Hernandez-Tamames, Juan A.; van Osch, Matthias J.; Asllani, Iris

Partial volume correction in arterial spin labeling perfusion MRI: A method to disentangle anatomy from physiology or an analysis step too far? Thumbnail


Authors

Flora A. Kennedy McConnell

Xavier Golay

Matthias Günther

Juan A. Hernandez-Tamames

Matthias J. van Osch

Iris Asllani



Abstract

The mismatch in the spatial resolution of Arterial Spin Labeling (ASL) MRI perfusion images and the anatomy of functionally distinct tissues in the brain leads to a partial volume effect (PVE), which in turn confounds the estimation of perfusion into a specific tissue of interest such as gray or white matter. This confound occurs because the image voxels contain a mixture of tissues with disparate perfusion properties, leading to estimated perfusion values that reflect primarily the volume proportions of tissues in the voxel rather than the perfusion of any particular tissue of interest within that volume. It is already recognized that PVE influences studies of brain perfusion, and that its effect might be even more evident in studies where changes in perfusion are co-incident with alterations in brain structure, such as studies involving a comparison between an atrophic patient population vs control subjects, or studies comparing subjects over a wide range of ages. However, the application of PVE correction (PVEc) is currently limited and the employed methodologies remain inconsistent.

In this article, we outline the influence of PVE in ASL measurements of perfusion, explain the main principles of PVEc, and provide a critique of the current state of the art for the use of such methods. Furthermore, we examine the current use of PVEc in perfusion studies and whether there is evidence to support its wider adoption.

We conclude that there is sound theoretical motivation for the use of PVEc alongside conventional, ‘uncorrected’, images, and encourage such combined reporting. Methods for PVEc are now available within standard neuroimaging toolboxes, which makes our recommendation straightforward to implement. However, there is still more work to be done to establish the value of PVEc as well as the efficacy and robustness of existing PVEc methods.

Citation

Chappell, M. A., McConnell, F. A. K., Golay, X., Günther, M., Hernandez-Tamames, J. A., van Osch, M. J., & Asllani, I. (2021). Partial volume correction in arterial spin labeling perfusion MRI: A method to disentangle anatomy from physiology or an analysis step too far?. NeuroImage, 238, Article 118236. https://doi.org/10.1016/j.neuroimage.2021.118236

Journal Article Type Article
Acceptance Date Jun 2, 2021
Online Publication Date Jun 4, 2021
Publication Date 2021-09
Deposit Date Jun 7, 2021
Publicly Available Date Jun 22, 2021
Journal NeuroImage
Print ISSN 1053-8119
Electronic ISSN 1095-9572
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 238
Article Number 118236
DOI https://doi.org/10.1016/j.neuroimage.2021.118236
Keywords Cognitive Neuroscience; Neurology
Public URL https://nottingham-repository.worktribe.com/output/5649417
Publisher URL https://www.sciencedirect.com/science/article/pii/S1053811921005139?via%3Dihub

Files





You might also like



Downloadable Citations