Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance

Yeboah, Siegfried K; Darkwa, Jo

Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance Thumbnail


Authors

Siegfried K Yeboah

JO DARKWA Jo.Darkwa@nottingham.ac.uk
Professor of Energy Storage Technologies



Abstract

Experimental and derived data from three Helically Coiled Oscillating Heat Pipes (HCOHPs) charged with ethanol, methanol and deionized water working fluids respectively are presented. The data was obtained from prototypes of the HCOHPs fabricated out of copper and tested under laboratory conditions. The primary data presented covers the HCOHP aspects, charging of the working fluid and temperature measurements from Omega K-Type Thermocouples installed on the evaporators, condensers, adiabatic sections, and on the cylindrical copper vessel integrated with it. The derived data covers the HCOHPs performances and thermal contact resistance experienced during laboratory testing. The data on the aspects and charging of the working fluid provides useful information for the validation of design parameters of other heat pipes. The measured temperature data and the derived performance data can used to validate the performance of heat pipes in other studies and to depict performance profiles in standard text and reference books. The nature of the data presented as a whole would be useful for validation and verification purposes for heat pipes and other passive heat transfer devices.

Citation

Yeboah, S. K., & Darkwa, J. (2020). Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance. Data in Brief, 33, Article 106505. https://doi.org/10.1016/j.dib.2020.106505

Journal Article Type Article
Acceptance Date Nov 2, 2020
Online Publication Date Nov 5, 2020
Publication Date 2020-12
Deposit Date Nov 4, 2020
Publicly Available Date Nov 4, 2020
Journal Data in Brief
Electronic ISSN 2352-3409
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 33
Article Number 106505
DOI https://doi.org/10.1016/j.dib.2020.106505
Keywords Data Validation; Design Parameters; Experimental Heat Transfer Data; Oscillating Heat Pipe; Thermal Management; Thermal Resistance; Working Fluids
Public URL https://nottingham-repository.worktribe.com/output/5017707
Publisher URL https://www.sciencedirect.com/science/article/pii/S2352340920313871
Additional Information This article is maintained by: Elsevier; Article Title: Experimental data on Helically Coiled Oscillating Heat Pipe (HCOHP) design and thermal performance; Journal Title: Data in Brief; CrossRef DOI link to publisher maintained version: https://doi.org/10.1016/j.dib.2020.106505; CrossRef DOI link to the associated document: https://doi.org/10.1016/j.ijthermalsci.2018.02.014; Content Type: article; Copyright: © 2020 The Authors. Published by Elsevier Inc.