This paper investigates the effect of electrostatic nonlinearity on the rate-sensing performance of imperfect ring-based Coriolis Vibrating Gyroscopes (CVGs) for devices having 8 and 16 evenly distributed electrodes. Mathematical models are developed for CVGs operating in (i) an open loop for a linear electrostatically trimmed device, (ii) a closed loop where a sense force balancing is applied to negate the sense quadrature response, and the effects of electrostatic nonlinearity are investigated for increasing drive amplitudes. The modeling indicates the nonlinear responses for 8- and 16-electrode arrangements are quite different, and this can be attributed to the nonlinear frequency imbalance, which depends on the drive and sense frequency softening as well as the presence of self-induced parametric excitation in the sense response. In open loop the 16-electrode arrangement exhibits much weaker levels of nonlinearity than the 8-electrode arrangement because the nonlinear frequency imbalance is less sensitive to drive amplitude. For devices operating in closed-loop with sense force balancing to ensure the drive and sense responses are in-phase/anti-phase, it is shown that ideal rate-sensing performance is achieved at large drive amplitudes for both 8- and 16-electrode arrangements. Using sense force balancing, rate sensing can be achieved using either the sense response or the required balancing voltage. For the latter, large nonlinear frequency imbalances and low damping levels enhance rate-sensing performance.
Citation
Arifin, D., & McWilliam, S. (2024). Rate-Sensing Performance of Imperfect Capacitive Ring-Based MEMS Coriolis Vibrating Gyroscopes at Large Drive Amplitudes †. Sensors, 25(7), 1-26. https://doi.org/10.3390/s25072263
Journal Article Type | Article |
---|---|
Acceptance Date | Apr 1, 2025 |
Online Publication Date | Apr 3, 2025 |
Publication Date | 2024-07 |
Deposit Date | Apr 4, 2025 |
Publicly Available Date | Apr 4, 2025 |
Journal | Sensors |
Electronic ISSN | 1424-8220 |
Publisher | MDPI |
Peer Reviewed | Peer Reviewed |
Volume | 25 |
Issue | 7 |
Article Number | 2263 |
Pages | 1-26 |
DOI | https://doi.org/10.3390/s25072263 |
Keywords | Coriolis vibrating gyroscope; electrostatic nonlinearities; electrostatic tuning; force balancing |
Public URL | https://nottingham-repository.worktribe.com/output/47283373 |
Publisher URL | https://www.mdpi.com/1424-8220/25/7/2263 |
Files
Rate-Sensing Performance of Imperfect Capacitive Ring-Based MEMS Coriolis Vibrating Gyroscopes at Large Drive Amplitudes
(3.9 Mb)
PDF
Publisher Licence URL
https://creativecommons.org/licenses/by/4.0/
Copyright Statement
© 2025 by the authors. Licensee MDPI, Basel, Switzerland.
This article is an open access article distributed under the terms and
conditions of the Creative Commons Attribution (CC BY) license
(https://creativecommons.org/ licenses/by/4.0/).
You might also like
Electrostatic Nonlinear Trimming of Ring-Based MEMS Coriolis Vibrating Gyroscopes
(2022)
Presentation / Conference Contribution
Nonlinear performance enhancement of imperfect ring-based Coriolis Vibratory Gyroscopes
(2024)
Presentation / Conference Contribution
Improving the frequency stability of capacitive ring-based Coriolis Vibrating Gyroscopes
(2024)
Presentation / Conference Contribution