Abstract
Instead of the auxiliary power system, the ground power unit supplies to airplanes during stopovers in airports, which is an important means of reducing carbon emissions of airport. However, under the restraint of switching frequency and high dynamic response speed, a single control loop is usually implemented in 400 Hz voltage-source inverter, the sampling and control of the inductor current in the LC filter are avoided, result in the design of the control system being more difficult, and the direction of the dead-time compensation can not be obtained due to the lack of the current polarity. In view of the above problem, this paper firstly analyzes the influence on the output voltage of inverter due to the dead-time, including the errors of fundamental amplitude and phase, and the low-order harmonic distortion. Then, according to the state equation of the inductor current, a current observation model without zero drift is proposed to obtain the polarity of the inductor current. On this basis, feedforward compensation is carried out for the voltage error generated by the dead-time. Combined with the amplitude-frequency characteristic curve, the parameter optimization design method of the single closed-loop proportional-resonant controller is presented. Finally, a simulation model and an experimental platform are established to verify the feasibility and effectiveness of the current observation model, dead-time compensation method and controller parameter optimization design method proposed in this paper.
Citation
Xu, W., Yang, T., & Miao, Y. (2024). Dead-time compensation and single-loop control strategy for ground power unit. Energy Reports, 11, 2983-2990. https://doi.org/10.1016/j.egyr.2024.02.055
Journal Article Type | Article |
---|---|
Acceptance Date | Feb 26, 2024 |
Online Publication Date | Feb 29, 2024 |
Publication Date | 2024-06 |
Deposit Date | Sep 16, 2024 |
Publicly Available Date | Sep 26, 2024 |
Journal | Energy Reports |
Electronic ISSN | 2352-4847 |
Publisher | Elsevier |
Peer Reviewed | Peer Reviewed |
Volume | 11 |
Pages | 2983-2990 |
DOI | https://doi.org/10.1016/j.egyr.2024.02.055 |
Public URL | https://nottingham-repository.worktribe.com/output/36560834 |
Publisher URL | https://www.sciencedirect.com/science/article/pii/S2352484724001343?via%3Dihub |
Files
Dead-time compensation and single-loop control strategy for ground power unit
(3.6 Mb)
PDF
Publisher Licence URL
https://creativecommons.org/licenses/by-nc-nd/4.0/
You might also like
Parasitic Inductance Impact of a High-Turn-Ratio Half Bridge Active Clamped Converter for More-Electric Aircraft Applications
(2024)
Presentation / Conference Contribution
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search