Fully angularly resolved 3D microrheology with optical tweezers

Matheson, Andrew B; Mendonca, Tania; Smith, Matthew G; Sutcliffe, Ben; Fernandez, Andrea Jannina; Paterson, Lynn; Dalgarno, Paul A; Wright, Amanda J; Tassieri, Manlio

Fully angularly resolved 3D microrheology with optical tweezers Thumbnail


Authors

Andrew B Matheson

Matthew G Smith

Ben Sutcliffe

Andrea Jannina Fernandez

Lynn Paterson

Paul A Dalgarno

Manlio Tassieri



Abstract

Microrheology with optical tweezers (MOT) is an all-optical technique that allows the user to investigate a materials’ viscoelastic properties at microscopic scales, and is particularly useful for those materials that feature complex microstructures, such as biological samples. MOT is increasingly being employed alongside 3D imaging systems and particle tracking methods to generate maps showing not only how properties may vary between different points in a sample but also how at a single point the viscoelastic properties may vary with direction. However, due to the diffraction limited shape of focussed beams, optical traps are inherently anisotropic in 3D. This can result in a significant overestimation of the fluids’ viscosity in certain directions. As such, the rheological properties can only be accurately probed along directions parallel or perpendicular to the axis of trap beam propagation. In this work, a new analytical method is demonstrated to overcome this potential artefact. This is achieved by performing principal component analysis on 3D MOT data to characterise the trap, and then identify the frequency range over which trap anisotropy influences the data. This approach is initially applied to simulated data for a Newtonian fluid where the trap anisotropy induced maximum error in viscosity is reduced from ~ 150% to less than 6%. The effectiveness of the method is corroborated by experimental MOT measurements performed with water and gelatine solutions, thus confirming that the microrheology of a fluid can be extracted reliably across a wide frequency range and in any arbitrary direction. This work opens the door to fully spatially and angularly resolved 3D mapping of the rheological properties of soft materials over a broad frequency range.

Citation

Matheson, A. B., Mendonca, T., Smith, M. G., Sutcliffe, B., Fernandez, A. J., Paterson, L., …Tassieri, M. (2024). Fully angularly resolved 3D microrheology with optical tweezers. Rheologica Acta, 63(3), 205-217. https://doi.org/10.1007/s00397-024-01435-1

Journal Article Type Article
Acceptance Date Jan 12, 2024
Online Publication Date Feb 8, 2024
Publication Date 2024-03
Deposit Date Mar 8, 2024
Publicly Available Date Mar 12, 2024
Journal Rheologica Acta
Print ISSN 0035-4511
Electronic ISSN 1435-1528
Publisher Springer Verlag
Peer Reviewed Peer Reviewed
Volume 63
Issue 3
Pages 205-217
DOI https://doi.org/10.1007/s00397-024-01435-1
Keywords Computer modeling, Microrheology, Viscosity, Simulation
Public URL https://nottingham-repository.worktribe.com/output/31159678
Publisher URL https://link.springer.com/article/10.1007/s00397-024-01435-1