Dr WALID TIZANI walid.tizani@nottingham.ac.uk
ASSOCIATE PROFESSOR
Dr WALID TIZANI walid.tizani@nottingham.ac.uk
ASSOCIATE PROFESSOR
Mohammed Mahmood
Dionysios Bournas
© 2020 American Society of Civil Engineers. Previous research on blind-bolted connections to hollow columns have provided a wealth of experimental data but little information on parametric analytical models to guide their design. One of the connection components that requires further understanding is the column-face bending. This paper presents the results and evaluation of experimental tests and finite element analyses for the bending behavior of the column-face component. Tests were conducted on full-scale connections to investigate the effect of concrete type and strength on the component. The results demonstrated that concrete strength has a direct influence on component strength and stiffness. The increase in concrete strength correlated with a significant increase in component strength. The increase in component stiffness was less significant, and is found to be limited by the column slenderness ratio (width/thickness). Slenderness ratio limits were defined beyond which the increase in concrete strength has no effect on component stiffness. A formula for evaluating the confinement effect on the concrete infill is proposed. The strength and stiffness of the component were not affected when using self-compacting concrete, but the use of lightweight concrete reduced both strength and stiffness. The failure mode of the component is bolt anchorage failure followed by a complete yielding of the column face plate around the bolts.
Tizani, W., Mahmood, M., & Bournas, D. (2020). Effect of Concrete Infill and Slenderness on Column-Face Component in Anchored Blind-Bolt Connections. Journal of Structural Engineering, 146(4), 1-18. https://doi.org/10.1061/%28ASCE%29ST.1943-541X.0002557
Journal Article Type | Article |
---|---|
Acceptance Date | Aug 19, 2019 |
Online Publication Date | Feb 6, 2020 |
Publication Date | 2020-04 |
Deposit Date | Sep 9, 2019 |
Publicly Available Date | Sep 9, 2019 |
Journal | Journal of Structural Engineering (United States) |
Print ISSN | 0733-9445 |
Electronic ISSN | 1943-541X |
Publisher | American Society of Civil Engineers |
Peer Reviewed | Peer Reviewed |
Volume | 146 |
Issue | 4 |
Article Number | 04020041 |
Pages | 1-18 |
DOI | https://doi.org/10.1061/%28ASCE%29ST.1943-541X.0002557 |
Keywords | Anchored bolted connection; column face bending; concrete strength; concrete filled tubular columns |
Public URL | https://nottingham-repository.worktribe.com/output/2590872 |
Publisher URL | https://ascelibrary.org/doi/10.1061/%28ASCE%29ST.1943-541X.0002557 |
Additional Information | This material may be downloaded for personal use only. Any other use requires prior permission of the American Society of Civil Engineers. This material may be found at https://ascelibrary.org/doi/10.1061/%28ASCE%29ST.1943-541X.0002557 |
Contract Date | Sep 9, 2019 |
Effect of concrete infill and slenderness on column face component in anchored blind-bolt connections
(4.5 Mb)
PDF
Column face bending in anchored blind-bolted connections to concrete filled hollow sections
(2024)
Journal Article
Semantic Web for BIM-Based Automated Project Management and Control: A Review
(2024)
Presentation / Conference Contribution
Bond behaviour of prestressed basalt textile reinforced concrete
(2024)
Journal Article
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
Apache License Version 2.0 (http://www.apache.org/licenses/)
Apache License Version 2.0 (http://www.apache.org/licenses/)
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search