Snehansh Roy Chaudhary
Diagnostic Sensitivity of Unenhanced CT for Cerebral Venous Thrombosis: Can Clot Density Measurement Replace CT Venogram?
Chaudhary, Snehansh Roy; Chunara, Mohamed; McLeavy, Chris; Qayyum, Haisum; Cusack, James; Paton, David; Hare, James; Ganguly, Akash
Authors
Mohamed Chunara
Chris McLeavy
Haisum Qayyum
James Cusack
Professor DAVID PATON DAVID.PATON@NOTTINGHAM.AC.UK
PROFESSOR OF INDUSTRIAL ECONOMICS
James Hare
Akash Ganguly
Abstract
Objectives Cerebral venous sinus thrombosis is an important cause of stroke in young adults. Noncontrast-enhanced CT head (NECT) is almost always the first investigation. Our objectives were as follows:1. How accurately does venous sinus density on NECT predict the presence of clot on CT venogram (CTV)?2. Whether repeated measurements changed the confidence?3. How many venous sinus thrombus would be missed if we do not do a CTV?4. Can clot density measurement replace CTV? Methods Multicenter case-control study was designed with data from seven hospitals. Inclusion criteria: all CT and magnetic resonance imaging venograms with a prior NECT, performed between 1.1.2018 and 31.12.2018 (12 months), were included. Hounsfield unit (HU) values were calculated at the site of highest density on the NECT. Logistic regression analysis was performed using STATA. Result Two-hundred seventy-seven cases met the criteria with 33 positive cerebral venous thrombosis (density on NECT 60-92 HU) and 244 negative examinations (density on NECT 31-68 HU). Area under the curve for average clot density on NECT was 0.9984. Conclusion We found a strong relationship between sinus density on NECT and outcome of CTV. Repeating density measurements did not add any predictive value or changed outcome. Advances in Knowledge Density 70 HU or higher on NECT always resulted in a positive CTV but would miss a fifth of the positives. Cutoff at 60 HU would not miss any but result in significant false positives. An efficient option could be to limit CTV to sinus densities 60 to 70 HU only. However, a larger study would be required for such change in practice.
Citation
Chaudhary, S. R., Chunara, M., McLeavy, C., Qayyum, H., Cusack, J., Paton, D., Hare, J., & Ganguly, A. (2023). Diagnostic Sensitivity of Unenhanced CT for Cerebral Venous Thrombosis: Can Clot Density Measurement Replace CT Venogram?. Indian Journal of Radiology and Imaging, 33(02), 187-194. https://doi.org/10.1055/s-0043-1761184
Journal Article Type | Article |
---|---|
Acceptance Date | Dec 8, 2022 |
Online Publication Date | Feb 11, 2023 |
Publication Date | 2023-04 |
Deposit Date | Jun 22, 2023 |
Publicly Available Date | Jun 22, 2023 |
Journal | Indian Journal of Radiology and Imaging |
Print ISSN | 0971-3026 |
Electronic ISSN | 1998-3808 |
Publisher | Medknow Publications |
Peer Reviewed | Peer Reviewed |
Volume | 33 |
Issue | 02 |
Pages | 187-194 |
DOI | https://doi.org/10.1055/s-0043-1761184 |
Keywords | CT - density - head - unenhanced - venogram |
Public URL | https://nottingham-repository.worktribe.com/output/17386203 |
Publisher URL | https://www.thieme-connect.de/products/ejournals/abstract/10.1055/s-0043-1761184 |
Files
18689
(4.1 Mb)
PDF
Publisher Licence URL
https://creativecommons.org/licenses/by-nc-nd/4.0/
You might also like
Law, Ethics and Lockdowns: impacts on life, liberty and the economy
(2023)
Journal Article
Financial transaction taxes and market structure: lessons from the gambling industry
(2022)
Journal Article
Is assisted suicide a substitute for unassisted suicide?
(2022)
Journal Article
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search