Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity via Dielectric Dissipation Factor Measurements

Naderiallaf, Hadi; Giangrande, Paolo; Galea, Michael

Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity via Dielectric Dissipation Factor Measurements Thumbnail


Authors

Paolo Giangrande

Michael Galea



Abstract

This experimental study evaluates the ageing rate associated with partial discharges (PD) activity for a Type-II insulated wire (i.e., Glass fibre), relying on the dielectric dissipation factor (DDF) and capacitance tip-up measurements. The employed specimens model the turn-to-turn insulation for low-voltage electrical machines. The turn-to-turn insulation was investigated because is the weakest point of the whole insulation system. The repetitive partial discharge inception voltage (RPDIV) is determined for unipolar and bipolar square waveform excitations with different rise times and frequencies. Then, the samples are stressed constantly under RPDIV at several exposure times for ageing purposes. The DDF and capacitance tip-up measurements are performed at the end of each ageing cycle. The reported findings enable the definition of indicators for the PD activity through the selected diagnostic markers (i.e., DDF and insulation capacitance). In addition, the proposed approach can provide reliable information on the Glass fibre ageing level associated with PD activity, comparing the harmfulness of different steep-fronted square waveforms.

Citation

Naderiallaf, H., Giangrande, P., & Galea, M. (2022). Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity via Dielectric Dissipation Factor Measurements. In 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD 2022) (98-102). https://doi.org/10.23919/CMD54214.2022.9991482

Presentation Conference Type Edited Proceedings
Conference Name 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD)
Start Date Nov 13, 2022
End Date Nov 18, 2022
Acceptance Date Nov 13, 2022
Online Publication Date Jan 2, 2023
Publication Date Nov 13, 2022
Deposit Date Apr 3, 2023
Publicly Available Date Apr 17, 2023
Publisher Institute of Electrical and Electronics Engineers
Volume 1 vol
Pages 98-102
Book Title 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD 2022)
ISBN 9781665470155
DOI https://doi.org/10.23919/CMD54214.2022.9991482
Public URL https://nottingham-repository.worktribe.com/output/16217213
Publisher URL https://ieeexplore.ieee.org/document/9991482
Additional Information H. Naderiallaf, P. Giangrande and M. Galea, "Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity via Dielectric Dissipation Factor Measurements," 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD), Kitakyushu, Japan, 2022, pp. 98-102, doi: 10.23919/CMD54214.2022.9991482.