Dr. HADI NADERIALLAF HADI.NADERIALLAF@NOTTINGHAM.AC.UK
Research Fellow
Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity via Dielectric Dissipation Factor Measurements
Naderiallaf, Hadi; Giangrande, Paolo; Galea, Michael
Authors
Paolo Giangrande
Michael Galea
Abstract
This experimental study evaluates the ageing rate associated with partial discharges (PD) activity for a Type-II insulated wire (i.e., Glass fibre), relying on the dielectric dissipation factor (DDF) and capacitance tip-up measurements. The employed specimens model the turn-to-turn insulation for low-voltage electrical machines. The turn-to-turn insulation was investigated because is the weakest point of the whole insulation system. The repetitive partial discharge inception voltage (RPDIV) is determined for unipolar and bipolar square waveform excitations with different rise times and frequencies. Then, the samples are stressed constantly under RPDIV at several exposure times for ageing purposes. The DDF and capacitance tip-up measurements are performed at the end of each ageing cycle. The reported findings enable the definition of indicators for the PD activity through the selected diagnostic markers (i.e., DDF and insulation capacitance). In addition, the proposed approach can provide reliable information on the Glass fibre ageing level associated with PD activity, comparing the harmfulness of different steep-fronted square waveforms.
Citation
Naderiallaf, H., Giangrande, P., & Galea, M. (2022). Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity via Dielectric Dissipation Factor Measurements. In 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD 2022) (98-102). https://doi.org/10.23919/CMD54214.2022.9991482
Presentation Conference Type | Edited Proceedings |
---|---|
Conference Name | 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD) |
Start Date | Nov 13, 2022 |
End Date | Nov 18, 2022 |
Acceptance Date | Nov 13, 2022 |
Online Publication Date | Jan 2, 2023 |
Publication Date | Nov 13, 2022 |
Deposit Date | Apr 3, 2023 |
Publicly Available Date | Apr 17, 2023 |
Publisher | Institute of Electrical and Electronics Engineers |
Volume | 1 vol |
Pages | 98-102 |
Book Title | 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD 2022) |
ISBN | 9781665470155 |
DOI | https://doi.org/10.23919/CMD54214.2022.9991482 |
Public URL | https://nottingham-repository.worktribe.com/output/16217213 |
Publisher URL | https://ieeexplore.ieee.org/document/9991482 |
Additional Information | H. Naderiallaf, P. Giangrande and M. Galea, "Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity via Dielectric Dissipation Factor Measurements," 2022 9th International Conference on Condition Monitoring and Diagnosis (CMD), Kitakyushu, Japan, 2022, pp. 98-102, doi: 10.23919/CMD54214.2022.9991482. |
Files
Glass Fibre Insulated Wire Assessment Under Partial Discharges Activity Via Dielectric Dissipation Factor Measurements
(536 Kb)
PDF
Publisher Licence URL
No License Set (All rights reserved)
You might also like
Air Pressure Impact on the Avalanche Size for Turn-to-Turn Insulation of Inverter-Fed Motors
(2023)
Journal Article
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search