Parametric analysis of a cross-flow membrane-based parallel-plate liquid desiccant dehumidification system: numerical and experimental data (2017)
Journal Article
Bai, H., Zhu, J., Chen, Z., & Chu, J. (2018). Parametric analysis of a cross-flow membrane-based parallel-plate liquid desiccant dehumidification system: numerical and experimental data. Energy and Buildings, 158, https://doi.org/10.1016/j.enbuild.2017.10.018

Operating parameters of a membrane-based parallel-plate liquid desiccant dehumidification system are investigated in this paper. The liquid desiccant and air are in a cross-flow arrangement, and separated by semi-permeable membranes to avoid carry-ov... Read More about Parametric analysis of a cross-flow membrane-based parallel-plate liquid desiccant dehumidification system: numerical and experimental data.

Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system (2017)
Journal Article
Bai, H., Zhu, J., Chen, Z., Ma, L., Wang, R., & Li, T. (2017). Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system. Applied Thermal Engineering, 119, https://doi.org/10.1016/j.applthermaleng.2017.03.058

A membrane-based liquid desiccant dehumidification system is one of high energy efficient dehumidification approaches, which allows heat and moisture transfers between air stream and desiccant solution without carryover problem. The system performanc... Read More about Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system.

Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations (2017)
Journal Article
Chen, Z., Zhu, J., & Bai, H. (2017). Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations. Energy and Buildings, 139, https://doi.org/10.1016/j.enbuild.2017.01.046

A membrane-based liquid desiccant dehumidification cooling system is studied in this paper for energy efficient air conditioning with independent temperature and humidity controls. The system mainly consists of a dehumidifier, a regenerator, an evapo... Read More about Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations.

Experimental study of a membrane-based dehumidification cooling system (2016)
Journal Article
Chen, Z., Zhu, J., Bai, H., Yan, Y., & Zhang, L. (2017). Experimental study of a membrane-based dehumidification cooling system. Applied Thermal Engineering, 115, https://doi.org/10.1016/j.applthermaleng.2016.10.153

Membrane-based liquid desiccant dehumidification has attracted increasing interests with elimination of solution droplets carryover problem. In this study, a membrane-based hybrid liquid desiccant dehumidification cooling system is developed, which i... Read More about Experimental study of a membrane-based dehumidification cooling system.

Theoretical analysis of a membrane-based cross-flow liquid desiccant system (2016)
Presentation / Conference Contribution
Bai, H., Chen, Z., Xu, H., & Zhu, J. Theoretical analysis of a membrane-based cross-flow liquid desiccant system. Presented at International Symposium of Heat Transfer and Heat Powered Cycles 2016

Liquid desiccant air dehumidification has become one of the most widely used dehumidification technologies with advantages of high efficiency, no liquid condensate droplets and capability of energy storage. In this paper a cross-flow mathematical mod... Read More about Theoretical analysis of a membrane-based cross-flow liquid desiccant system.

Effect of resistive load on the performance of an organic Rankine cycle with a scroll expander (2016)
Journal Article
Zhua, J., Chen, Z., Huang, H., & Yan, Y. (2016). Effect of resistive load on the performance of an organic Rankine cycle with a scroll expander. Energy, 95, https://doi.org/10.1016/j.energy.2015.11.048

An experimental investigation is performed for an organic Rankine cycle system with different electrical resistive loads. The test rig is set up with a small scroll expander-generator unit, a boiler and a magnetically coupled pump. R134a is used as t... Read More about Effect of resistive load on the performance of an organic Rankine cycle with a scroll expander.

Cafestol extraction yield from different coffee brew mechanisms (2012)
Journal Article
Zhang, C., Linforth, R. S., & Fisk, I. D. (2012). Cafestol extraction yield from different coffee brew mechanisms. Food Research International, 49(1), https://doi.org/10.1016/j.foodres.2012.06.032

The extraction yield of cafestol from roast and ground (R&G) coffee beans was evaluated using brews prepared
by four brewing mechanisms (boiled, Turkish, French Press and Mocha Pot). The cafestol content of the R&G coffee and the resulting brews was... Read More about Cafestol extraction yield from different coffee brew mechanisms.

Experimental study of a membrane-based dehumidification cooling system
Presentation / Conference Contribution
Chen, Z., Bai, H., Ye, Z., & Zhu, J. Experimental study of a membrane-based dehumidification cooling system. Presented at International Symposium of Heat Transfer and Heat Powered Cycles 2016

Membrane-based liquid desiccant dehumidification has attracted increasing interests with elimination of solution droplets carryover problem. A membrane-based hybrid liquid desiccant dehumidification cooling system is developed in this study, which ha... Read More about Experimental study of a membrane-based dehumidification cooling system.