Skip to main content

Research Repository

Advanced Search

All Outputs (6)

Intra-tracheal multiplexed sensing of contact pressure and perfusion (2021)
Journal Article
Correia, R., Gadsby, B., Korposh, S., Norris, A. M., Hayes-Gill, B. R., Sinha, R., …Morgan, S. P. (2022). Intra-tracheal multiplexed sensing of contact pressure and perfusion. Biomedical Optics Express, 13(1), 48-64. https://doi.org/10.1364/BOE.442165

Incorrect endotracheal tube (ETT) cuff inflation pressure causes significant problems for intubated patients. The technical development and first in vivo use of a smart ETT for measurements at the cuff-trachea interface during mechanical ventilation... Read More about Intra-tracheal multiplexed sensing of contact pressure and perfusion.

Fabrication of Humidity-Resistant Optical Fiber Sensor for Ammonia Sensing Using Diazo Resin-Photocrosslinked Films with a Porphyrin-Polystyrene Binary Mixture (2021)
Journal Article
Ahmed, S., Park, Y., Okuda, H., Ono, S., Korposh, S., & Lee, S.-W. (2021). Fabrication of Humidity-Resistant Optical Fiber Sensor for Ammonia Sensing Using Diazo Resin-Photocrosslinked Films with a Porphyrin-Polystyrene Binary Mixture. Sensors, 21(18), Article 6176. https://doi.org/10.3390/s21186176

Ammonia gas sensors were fabricated via layer-by-layer (LbL) deposition of diazo resin (DAR) and a binary mixture of tetrakis(4-sulfophenyl)porphine (TSPP) and poly(styrene sulfonate) (PSS) onto the core of a multimode U-bent optical fiber. The penet... Read More about Fabrication of Humidity-Resistant Optical Fiber Sensor for Ammonia Sensing Using Diazo Resin-Photocrosslinked Films with a Porphyrin-Polystyrene Binary Mixture.

Optical Fibre Sensor for Capillary Refill Time and Contact Pressure Measurements under the Foot (2021)
Journal Article
Ballaji, H. K., Correia, R., Liu, C., Korposh, S., Hayes-Gill, B. R., Musgrove, A., & Morgan, S. P. (2021). Optical Fibre Sensor for Capillary Refill Time and Contact Pressure Measurements under the Foot. Sensors, 21(18), Article 6072. https://doi.org/10.3390/s21186072

Capillary refill time (CRT) refers to the time taken for body tissue to regain its colour after an applied blanching pressure is released. Usually, pressure is manually applied and not measured. Upon release of pressure, simple mental counting is typ... Read More about Optical Fibre Sensor for Capillary Refill Time and Contact Pressure Measurements under the Foot.

Optical fibre Sensor for Simultaneous Temperature and Relative Humidity Measurement: Towards Absolute Humidity Evaluation (2021)
Journal Article
He, C., Korposh, S., Correia, R., Liu, L., Hayes-Gill, B. R., & Morgan, S. P. (2021). Optical fibre Sensor for Simultaneous Temperature and Relative Humidity Measurement: Towards Absolute Humidity Evaluation. Sensors and Actuators B: Chemical, 344, Article 130154. https://doi.org/10.1016/j.snb.2021.130154

Temperature and humidity are essential parameters in monitoring the health of patients in critical care. An optical fibre sensor has been developed for simultaneous measurement of relative humidity (RH) and temperature at a single optical fibre tip b... Read More about Optical fibre Sensor for Simultaneous Temperature and Relative Humidity Measurement: Towards Absolute Humidity Evaluation.

Carboxyl-fentanyl detection using optical fibre grating-based sensors functionalised with molecularly imprinted nanoparticles (2021)
Journal Article
Liu, L. L., Grillo, F., Canfarotta, F., Whitcombe, M., Morgan, S. P., Piletsky, S., …Korposh, S. (2021). Carboxyl-fentanyl detection using optical fibre grating-based sensors functionalised with molecularly imprinted nanoparticles. Biosensors and Bioelectronics, 177, Article 113002. https://doi.org/10.1016/j.bios.2021.113002

Butyrylfentanyl is a new designer drug reported with growing use and related deaths. Routine toxicological analyses of this novel synthetic opioid drug have not been established yet. This work reports a fibre optic sensor that measures carboxyl-fenta... Read More about Carboxyl-fentanyl detection using optical fibre grating-based sensors functionalised with molecularly imprinted nanoparticles.

Development and validation of a novel fibre-optic respiratory rate sensor (FiRRS) integrated in oxygen delivery devices (2021)
Journal Article
Sinha, R., Hernandez, F., He, C., Korposh, S., Correia, R. N. G., Norris, A., …Morgan, S. P. (2021). Development and validation of a novel fibre-optic respiratory rate sensor (FiRRS) integrated in oxygen delivery devices. Journal of Physics D: Applied Physics, 54(12), Article 124002. https://doi.org/10.1088/1361-6463/abd061

© 2021 The Author(s). Respiratory rate (RR) monitoring provides crucial information on the overall health condition of patients and a reliable, low cost RR monitor for normal hospital inpatient or home use would be of significant benefit. The propose... Read More about Development and validation of a novel fibre-optic respiratory rate sensor (FiRRS) integrated in oxygen delivery devices.