Skip to main content

Research Repository

Advanced Search

Reliability analysis of deteriorated post-tensioned concrete bridges: The case study of Ynys-y-Gwas bridge in UK

Al-Mosawe, Doha; Neves, Luis; Owen, John

Authors

Doha Al-Mosawe

Luis Neves



Abstract

Concrete structures are exposed to aggressive environmental conditions that lead to corrosion of the embedded reinforcement and pre-stressing steel. Consequently, the safety of concrete structures may be compromised, and this requires a significant budgets to repair and maintain critical infrastructure. Prediction of structural safety can lead to significant reductions in maintenance costs by maximising the impact of investments. The aim of this paper is to establish a framework to assess the reliability of existing post-tensioned concrete bridges. A time-dependent reliability analysis of an existing post-tensioned involving the assessment of Ynys-y-Gwas bridge has been presented in this study. The main cause of failure of this bridge was corrosion of tendons, making it a relevant case study to evaluate the effect of corrosion on bridge safety. Uncertainties associated with material properties, geometry, loads and corrosion parameters are taken into account. The probabilistic models of the uncertainties are combined with a non-linear finite element analysis to study the effect of tendons pitting corrosion on the post-tensioned concrete bridge. The limit state function considered is flexural strength. The Monte-Carlo simulation (MCS) method is used to compute the statistical parameters of the resisting bending moment through a MATLAB code running ABAQUS. It was found that the reliability index for the first year of bridge service life is below the minimum value acceptable for structures. The study confirmed that this bridge was a high risk structure due to its design and location. The proposed framework can be used by engineers and researchers as a tool to support decision for segmental post-tensioned (PT) bridges maintenance since they need for a regular inspection due to their risk to corrosion.

Citation

Al-Mosawe, D., Neves, L., & Owen, J. (2022). Reliability analysis of deteriorated post-tensioned concrete bridges: The case study of Ynys-y-Gwas bridge in UK. Structures, 41, 242-259. https://doi.org/10.1016/j.istruc.2022.04.094

Journal Article Type Article
Acceptance Date Apr 29, 2022
Online Publication Date May 12, 2022
Publication Date 2022-07
Deposit Date Mar 5, 2024
Journal Structures
Electronic ISSN 2352-0124
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 41
Pages 242-259
DOI https://doi.org/10.1016/j.istruc.2022.04.094
Keywords Safety, Risk, Reliability and Quality; Building and Construction; Architecture; Civil and Structural Engineering
Public URL https://nottingham-repository.worktribe.com/output/8309838
Publisher URL https://www.sciencedirect.com/science/article/abs/pii/S2352012422003551?via%3Dihub