Heather Fortnum
A programme of studies including assessment of diagnostic accuracy of school hearing screening tests and a cost-effectiveness model of school entry hearing screening programmes
Fortnum, Heather; Ukoumunne, Obioha C.; Hyde, Chris; Taylor, Rod S.; Ozolins, Mara; Errington, Sam; Zhelev, Zhivko; Pritchard, Clive; Benton, Claire; Moody, Joanne; Cocking, Laura; Watson, Julian; Roberts, Sarah
Authors
Obioha C. Ukoumunne
Chris Hyde
Rod S. Taylor
Mara Ozolins
Sam Errington
Zhivko Zhelev
Clive Pritchard
Claire Benton
Joanne Moody
Laura Cocking
Julian Watson
Sarah Roberts
Abstract
Background
Identification of permanent hearing impairment at the earliest possible age is crucial to maximise the development of speech and language. Universal newborn hearing screening identifies the majority of the 1 in 1000 children born with a hearing impairment, but later onset can occur at any time and there is no optimum time for further screening. A universal but non-standardised school entry screening (SES) programme is in place in many parts of the UK but its value is questioned.
Objectives
To evaluate the diagnostic accuracy of hearing screening tests and the cost-effectiveness of the SES programme in the UK.
Design
Systematic review, case–control diagnostic accuracy study, comparison of routinely collected data for services with and without a SES programme, parental questionnaires, observation of practical implementation and cost-effectiveness modelling.
Setting
Second- and third-tier audiology services; community.
Participants
Children aged 4–6 years and their parents.
Main outcome measures
Diagnostic accuracy of two hearing screening devices, referral rate and source, yield, age at referral and cost per quality-adjusted life-year.
Results
The review of diagnostic accuracy studies concluded that research to date demonstrates marked variability in the design, methodological quality and results. The pure-tone screen (PTS) (Amplivox, Eynsham, UK) and HearCheck (HC) screener (Siemens, Frimley, UK) devices had high sensitivity (PTS ≥ 89%, HC ≥ 83%) and specificity (PTS ≥ 78%, HC ≥ 83%) for identifying hearing impairment. The rate of referral for hearing problems was 36% lower with SES (Nottingham) relative to no SES (Cambridge) [rate ratio 0.64, 95% confidence interval (CI) 0.59 to 0.69; p < 0.001]. The yield of confirmed cases did not differ between areas with and without SES (rate ratio 0.82, 95% CI 0.63 to 1.06; p = 0.12). The mean age of referral did not differ between areas with and without SES for all referrals but children with confirmed hearing impairment were older at referral in the site with SES (mean age difference 0.47 years, 95% CI 0.24 to 0.70 years; p < 0.001). Parental responses revealed that the consequences to the family of the referral process are minor. A SES programme is unlikely to be cost-effective and, using base-case assumptions, is dominated by a no screening strategy. A SES programme could be cost-effective if there are fewer referrals associated with SES programmes or if referrals occur more quickly with SES programmes.
Conclusions
A SES programme using the PTS or HC screener is unlikely to be effective in increasing the identified number of cases with hearing impairment and lowering the average age at identification and is therefore unlikely to represent good value for money. This finding is, however, critically dependent on the results of the observational study comparing Nottingham and Cambridge, which has limitations. The following are suggested: systematic reviews of the accuracy of devices used to measure hearing at school entry; characterisation and measurement of the cost-effectiveness of different approaches to the ad-hoc referral system; examination of programme specificity as opposed to test specificity; further observational comparative studies of different programmes; and opportunistic trials of withdrawal of SES programmes.
Citation
Fortnum, H., Ukoumunne, O. C., Hyde, C., Taylor, R. S., Ozolins, M., Errington, S., Zhelev, Z., Pritchard, C., Benton, C., Moody, J., Cocking, L., Watson, J., & Roberts, S. (2016). A programme of studies including assessment of diagnostic accuracy of school hearing screening tests and a cost-effectiveness model of school entry hearing screening programmes. Health Technology Assessment, 20(36), 1-178. https://doi.org/10.3310/hta20360
Journal Article Type | Article |
---|---|
Acceptance Date | Nov 1, 2015 |
Publication Date | 2016-05 |
Deposit Date | Jul 9, 2016 |
Publicly Available Date | Jul 9, 2016 |
Journal | Health Technology Assessment |
Print ISSN | 1366-5278 |
Electronic ISSN | 2046-4924 |
Publisher | NIHR Journals Library |
Peer Reviewed | Peer Reviewed |
Volume | 20 |
Issue | 36 |
Pages | 1-178 |
DOI | https://doi.org/10.3310/hta20360 |
Public URL | https://nottingham-repository.worktribe.com/output/782045 |
Publisher URL | https://www.journalslibrary.nihr.ac.uk/hta/hta20360/#/abstract |
Contract Date | Jul 9, 2016 |
Files
FullReport-hta20360.pdf
(13.9 Mb)
PDF
Copyright Statement
Copyright information regarding this work can be found at the following address: http://eprints.nottingham.ac.uk/end_user_agreement.pdf
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search