Abstract

We report a theoretical framework to explain the characteristics of Fabry-Pérot (FP) resonances excited in a thin film-based grating consisting of a thin gold layer and a rectangular dielectric grating in the sub-wavelength and near-wavelength grating regimes. The zeroth-order diffraction inside the grating layer forms an FP resonant cavity with effective refractive index arising from an averaging effect between the refractive indices of the grating material and the filling material between the grating grooves. A simplified model based on Fresnel equations and phase matching condition is proposed to predict the FP resonant mode for the grating structure, this is compared with rigorous coupled-wave analysis to determine its range of validity. We also compare the performance of the proposed structure with other thin film-based interferometers for refractive index sensing applications, in terms of, sensitivity, full width at half maximum, figure of merit and dynamic range. The proposed structure has a full width at half maximum around 10 times to 60 times narrower than conventional surface plasmon resonance and conventional FP resonators. Thus, the figure of merit is higher than Kretschmann based surface plasmon resonance and FP structures by a factor of 20 and 2 respectively with a wider dynamic range. The total energy stored in the grating resonant cavity is 5 and 20-fold greater than the surface plasmon resonance configuration and the conventional FP structures. Since the resonator discussed here is an open structure, it is far better suited for liquid sensing compared to a closed FP structure.

Citation

Sasivimolkul, S., Pechprasarn, S., & Somekh, M. G. (2021). Analysis of Open Grating-Based Fabry–Pérot Resonance Structures With Potential Applications for Ultrasensitive Refractive Index Sensing. IEEE Sensors Journal, 21(9), 10628-10636. https://doi.org/10.1109/jsen.2021.3063136

Journal Article Type Article
Acceptance Date Mar 9, 2021
Online Publication Date Mar 2, 2021
Publication Date May 1, 2021
Deposit Date Apr 11, 2021
Publicly Available Date Apr 15, 2021
Journal IEEE Sensors Journal
Print ISSN 1530-437X
Electronic ISSN 1558-1748
Publisher Institute of Electrical and Electronics Engineers
Peer Reviewed Peer Reviewed
Volume 21
Issue 9
Pages 10628-10636
DOI https://doi.org/10.1109/jsen.2021.3063136
Keywords Instrumentation; Electrical and Electronic Engineering