Abstract

The optically pumped magnetometer (OPM) is a viable means to detect magnetic fields generated by human brain activity. Compared to conventional detectors (superconducting quantum interference devices) OPMs are small, lightweight, flexible, and operate without cryogenics. This has led to a step change in instrumentation for magnetoencephalography (MEG), enabling a “wearable” scanner platform, adaptable to fit any head size, able to acquire data whilst subjects move, and offering improved data quality. Although many studies have shown the efficacy of ‘OPM-MEG’, one relatively untapped advantage relates to improved array design. Specifically, OPMs enable the simultaneous measurement of magnetic field components along multiple axes (distinct from a single radial orientation, as used in most conventional MEG systems). This enables characterisation of the magnetic field vector at all sensors, affording extra information which has the potential to improve source reconstruction. Here, we conduct a theoretical analysis of the critical parameters that should be optimised for effective source reconstruction. We show that these parameters can be optimised by judicious array design incorporating triaxial MEG measurements. Using simulations, we demonstrate how a triaxial array offers a dramatic improvement on our ability to differentiate real brain activity from sources of magnetic interference (external to the brain). Further, a triaxial system is shown to offer a marked improvement in the elimination of artefact caused by head movement. Theoretical results are supplemented by an experimental recording demonstrating improved interference reduction. These findings offer new insights into how future OPM-MEG arrays can be designed with improved performance.

Citation

Brookes, M. J., Boto, E., Rea, M., Shah, V., Osborne, J., Holmes, N., …Bowtell, R. (2021). Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system. NeuroImage, 236, Article 118025. https://doi.org/10.1016/j.neuroimage.2021.118025

Journal Article Type Article
Acceptance Date Mar 25, 2021
Online Publication Date Apr 7, 2021
Publication Date Aug 1, 2021
Deposit Date Jun 30, 2021
Publicly Available Date Jun 30, 2021
Journal NeuroImage
Print ISSN 1053-8119
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 236
Article Number 118025
DOI https://doi.org/10.1016/j.neuroimage.2021.118025
Keywords Cognitive Neuroscience; Neurology
Public URL https://nottingham-repository.worktribe.com/output/5438448
Publisher URL https://www.sciencedirect.com/science/article/pii/S1053811921003025?via%3Dihub

Files




You might also like



Downloadable Citations