Estimation of the infiltration rate of UK homes with the divide-by-20 rule and its comparison with site measurements

Vega Pasos, Alan; Zheng, Xiaofeng; Smith, Luke; Wood, Christopher

Estimation of the infiltration rate of UK homes with the divide-by-20 rule and its comparison with site measurements Thumbnail


Authors

Alan Vega Pasos

XIAOFENG ZHENG Xiaofeng.Zheng@nottingham.ac.uk
Assistant Professor - Building Services

Luke Smith



Abstract

Buildings are responsible for 40% of the global energy usage to which infiltration-caused heat losses are responsible for 30%. Air infiltration is the unintended flow of air through leakage paths and fundamentally determined by the airtightness of a building. In the United Kingdom, building airtightness is conventionally measured through a blower door test and used to predict air infiltration in conjunction with the divided-by-20 rule, which is a rule of thumb that has been adopted by SAP (Standard Assessment Procedure: a UK government's recommended method system for measuring the energy rating of residential dwellings) for the estimation of the infiltration-caused heat losses for dwellings. This paper assesses the representativeness of this rule of thumb by carrying out blower door and tracer gas tests in twenty one dwellings located in the East Midlands Region of the United Kingdom. Results showed that a divide-by-37 rule would be more representative. It was also seen that the air infiltration rate is overestimated by SAP when modifying factors are added. The errors are as high as 500% in some cases. The most affected dwellings were the tighter ones. A revision of the usage of the divide-by-20 rule and the modifying factors is advised

Citation

Vega Pasos, A., Zheng, X., Smith, L., & Wood, C. (2020). Estimation of the infiltration rate of UK homes with the divide-by-20 rule and its comparison with site measurements. Building and Environment, 185, Article 107275. https://doi.org/10.1016/j.buildenv.2020.107275

Journal Article Type Article
Acceptance Date Sep 5, 2020
Online Publication Date Sep 10, 2020
Publication Date 2020-11
Deposit Date Sep 10, 2020
Publicly Available Date Mar 29, 2024
Journal Building and Environment
Print ISSN 0360-1323
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 185
Article Number 107275
DOI https://doi.org/10.1016/j.buildenv.2020.107275
Keywords Airtightness, air infiltration, blower door, air leakage, SAP, divide-by-20
Public URL https://nottingham-repository.worktribe.com/output/4894828
Publisher URL https://www.sciencedirect.com/science/article/abs/pii/S0360132320306466