Skip to main content

Research Repository

Advanced Search

An integrated simulation of intermittent heating of multi-zone buildings by heat-pump heating systems with different terminal types

Xu, Baoping; Jiang, Peihong; Chen, Zhuo; Li, Qiangang; Wang, Xi; Yan, Yuying

An integrated simulation of intermittent heating of multi-zone buildings by heat-pump heating systems with different terminal types Thumbnail


Authors

Baoping Xu

Peihong Jiang

Zhuo Chen

Qiangang Li

Xi Wang



Abstract

Intermittent heating has been considered to be an effective way to achieve energy savings compared with continuous heating. However, recent studies have found that actual energy savings from intermittent heating vary greatly, depending on actual building conditions, terminals and heating supply systems. For multi-zone buildings adopting heat pumps with specific terminals, a comprehensive analysis of energy savings resulting from intermittent heating still needs to be done. In the present study, an integrated dynamic model is developed by considering the interaction of thermal processes among building envelopes, terminals, and heat pumps. Its reliability is verified in field tests, and a better accuracy was achieved when considering the radiant heat ratio of terminals. On this basis, the model together with a source and terminal control strategy is applied to simulate the thermal behavior of heat pump heating systems for buildings under various conditions. The effect of different terminals and building envelopes on room temperature variation and energy utilization by intermittent heating is analyzed. The simulation results and practical projects indicate that heat pump power consumption under intermittent heating may be lower, close to or even higher than that under continuous heating. The factors that affect the efficient of intermittent heating, including building and system thermal inertia, heat pump operation COP, the radiant heat ratio of terminals, need to be systematically considered. Specifically, fan-coil heating systems could use 16.48% less energy, while radiant floor heating systems consume more energy under intermittent heating. Heat pumps under continuous heating are more efficient in buildings with radiative heating systems and heavy envelopes.

Citation

Xu, B., Jiang, P., Chen, Z., Li, Q., Wang, X., & Yan, Y. (2023). An integrated simulation of intermittent heating of multi-zone buildings by heat-pump heating systems with different terminal types. Applied Thermal Engineering, 235, Article 121427. https://doi.org/10.1016/j.applthermaleng.2023.121427

Journal Article Type Article
Acceptance Date Aug 22, 2023
Online Publication Date Aug 22, 2023
Publication Date Nov 25, 2023
Deposit Date Oct 20, 2023
Publicly Available Date Aug 23, 2024
Journal Applied Thermal Engineering
Print ISSN 1359-4311
Electronic ISSN 1873-5606
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 235
Article Number 121427
DOI https://doi.org/10.1016/j.applthermaleng.2023.121427
Keywords Heat pump, Intermittent heating, Heating terminal, Integrated simulation, Thermal response
Public URL https://nottingham-repository.worktribe.com/output/24586122
Publisher URL https://www.sciencedirect.com/science/article/pii/S1359431123014564

Files





You might also like



Downloadable Citations