Comparison of laser Doppler and laser speckle contrast imaging using a concurrent processing system (2016)
Journal Article
Sun, S., Hayes-Gill, B. R., He, D., Zhu, Y., Huynh, N. T., & Morgan, S. P. (2016). Comparison of laser Doppler and laser speckle contrast imaging using a concurrent processing system. Optics and Lasers in Engineering, 83, https://doi.org/10.1016/j.optlaseng.2016.02.021

Full field laser Doppler imaging (LDI) and single exposure laser speckle contrast imaging (LSCI) are directly compared using a novel instrument which can concurrently image blood flow using both LDI and LSCI signal processing. Incorporating a commerc... Read More about Comparison of laser Doppler and laser speckle contrast imaging using a concurrent processing system.

Highly sensitive optical fibre long period grating biosensor anchored with silica core gold shell nanoparticles (2015)
Journal Article
Marques, L. M., Hernandez, F. U., James, S. W., Morgan, S. P., Clark, M., Tatam, R. P., & Korposh, S. (2016). Highly sensitive optical fibre long period grating biosensor anchored with silica core gold shell nanoparticles. Biosensors and Bioelectronics, 75, https://doi.org/10.1016/j.bios.2015.08.046

An optical fibre long period grating (LPG), modified with a coating of silica core gold shell (SiO2:Au) nanoparticles (NPs) deposited using the layer-by-layer method, was employed for the development of a biosensor. The SiO2:Au NPs were electrostatic... Read More about Highly sensitive optical fibre long period grating biosensor anchored with silica core gold shell nanoparticles.

Post-processing of polymer foam tissue scaffolds with high power ultrasound: A route to increased pore interconnectivity, pore size and fluid transport (2013)
Journal Article
Watson, N. J., Johal, R. K., Glover, Z., Reinwald, Y., White, L. J., Ghaemmaghami, A. M., Morgan, S. P., Rose, F. R., Povey, M. J., & Parker, N. G. (2013). Post-processing of polymer foam tissue scaffolds with high power ultrasound: A route to increased pore interconnectivity, pore size and fluid transport. Materials Science and Engineering: C, 33(8), 4825-4832. https://doi.org/10.1016/j.msec.2013.07.046

The aimof this work is to demonstrate that the structural and fluidic properties of polymer foamtissue scaffolds, post-fabrication but prior to the introduction of cells, can be engineered via exposure to high power ultrasound. Our analysis is suppor... Read More about Post-processing of polymer foam tissue scaffolds with high power ultrasound: A route to increased pore interconnectivity, pore size and fluid transport.

User needs elicitation via analytic hierarchy process (AHP): a case study on a Computed Tomography (CT) scanner (2013)
Journal Article
Pecchia, L., Martin, J. L., Ragozzino, A., Vanzanella, C., Scognamiglio, A., Mirarchi, L., & Morgan, S. P. (2013). User needs elicitation via analytic hierarchy process (AHP): a case study on a Computed Tomography (CT) scanner. BMC Medical Informatics and Decision Making, 13(2), https://doi.org/10.1186/1472-6947-13-2

Background: The rigorous elicitation of user needs is a crucial step for both medical device design and purchasing. However, user needs elicitation is often based on qualitative methods whose findings can be difficult to integrate into medical decisi... Read More about User needs elicitation via analytic hierarchy process (AHP): a case study on a Computed Tomography (CT) scanner.

CMOS sensors for imaging blood flow (2010)
Journal Article
Morgan, S., Hayes-Gill, B., & Crowe, J. (2010). CMOS sensors for imaging blood flow. Optics and Photonics News, 21(1), 32-37. https://doi.org/10.1364/OPN.21.1.000032

Smart CMOS sensors can extract parameters of interest from incoming signals at the sensor and therefore overcome the data bottleneck between sensor and processor. This enables full-field laser Doppler blood flow imaging to be obtained at a frame rate... Read More about CMOS sensors for imaging blood flow.

The design and characterisation of an optical VLSI processor for real time centroid detection (2002)
Journal Article
Pui, B. H., Hayes-Gill, B., Clark, M., Somekh, M., See, C., Piéri, J. F., Morgan, S. P., & Ng, A. (2002). The design and characterisation of an optical VLSI processor for real time centroid detection. Analog Integrated Circuits and Signal Processing, 32(1), 67-75. https://doi.org/10.1023/A%3A1016075825331

The integration of photo-detectors onto a standard CMOS integrated circuit is presented. This device provides the optical front end for a real time centroid detection system to be used as part of a larger system for implementing a Shack-Hartmann wave... Read More about The design and characterisation of an optical VLSI processor for real time centroid detection.

The Design of a Real Time VLSI Optical Centroid Processor (2002)
Presentation / Conference Contribution
Pui, B. H., Hayes-Gill, B., Clark, M., Somekh, M., See, C., Morgan, S., & Ng, A. (2002, June). The Design of a Real Time VLSI Optical Centroid Processor. Presented at IEEE International Conference on Sensors 2002, Orlando, Florida, USA

A real time VLSI optical centroid processor has been developed as part of a larger Shack-Hartmann wavefront sensor system for applications in adaptive optics. The implementation of the optical centroid detection system was demonstrated successfully u... Read More about The Design of a Real Time VLSI Optical Centroid Processor.

The design and characterisation of an optical VLSI processor for real time centroid detection (2001)
Presentation / Conference Contribution
Boon Hean Pui, Hayes-Gill, B., Clark, M., Somekh, M., See, C., Piéri, J. F., Morgan, S., & Ng, A. (2001, April). The design and characterisation of an optical VLSI processor for real time centroid detection. Presented at Design, Test, Integration, and Packaging of MEMS/MOEMS 2001, 2001, Cannes-Mandelieu, France

The integration of photo-detectors onto a standard CMOS integrated circuit is presented. This device provides the optical front end for a real time centroid detection system to be used as part of a larger system for implementing a Shack-Hartmann wave... Read More about The design and characterisation of an optical VLSI processor for real time centroid detection.