Experimental investigation of the use of sharp edges for the production of positive ions in field-ionization mass spectrometry (1968)
Journal Article
Blenkinsop, P., Job, B., Brailsford, D. F., Cross, C., & Robertson, A. (1968). Experimental investigation of the use of sharp edges for the production of positive ions in field-ionization mass spectrometry. International journal of mass spectrometry and ion processes, 1(6), 421-434. https://doi.org/10.1016/0020-7381%2868%2985019-3

Various commercial razor blades have been tested for field ionization performance and compared with edges prepared electrochemically from platinum and tungsten foils. The results are correlated with data obtained from electron micrographs of the vari... Read More about Experimental investigation of the use of sharp edges for the production of positive ions in field-ionization mass spectrometry.

Calculation of electric field strengths at a sharp edge (1968)
Journal Article
Brailsford, D. F., & Robertson, A. J. B. (1968). Calculation of electric field strengths at a sharp edge

Sharp edges were first used for field ionisation mass spectrometry by Beckey. Although Cross and Robertson found that etched metal foils were more effective than razor blades for field ionisation, blades are very convenient for determination of field... Read More about Calculation of electric field strengths at a sharp edge.