Incorporation and evolution of ZrO2 nano-particles in Pt-modified aluminide coating for high temperature applications (2016)
Journal Article
Qian, L., Xu, F., Voisey, K., Nekouie, V., Zhou, Z., Silberschmidt, V. V., & Hou, X. (2017). Incorporation and evolution of ZrO2 nano-particles in Pt-modified aluminide coating for high temperature applications. Surface and Coatings Technology, 311, https://doi.org/10.1016/j.surfcoat.2016.12.106

ZrO2 nano-particles were incorporated into electro-deposited PtAl coatings in an attempt to enhance their performance by exploiting the effect of reactive element oxides. PtAl coatings with and without ZrO2 particles were deposited onto three commerc... Read More about Incorporation and evolution of ZrO2 nano-particles in Pt-modified aluminide coating for high temperature applications.

Gas and liquid-fuelled HVOF spraying of Ni50Cr coating: microstructure and high temperature oxidation (2016)
Journal Article
Song, B., Pala, Z., Voisey, K., & Hussain, T. (in press). Gas and liquid-fuelled HVOF spraying of Ni50Cr coating: microstructure and high temperature oxidation. Surface and Coatings Technology, https://doi.org/10.1016/j.surfcoat.2016.07.046

Ni50Cr thermally sprayed coatings are widely used for high temperature oxidation and corrosion in thermal power plants. In this study, a commercially available gas atomised Ni50Cr powder was sprayed onto a power plant alloy (ASME P92) using both gas... Read More about Gas and liquid-fuelled HVOF spraying of Ni50Cr coating: microstructure and high temperature oxidation.

Effects of pre-cracking on small punch creep testing of a vacuum plasma-sprayed CoNiCrAlY coating (2016)
Journal Article
Chen, H., Hyde, T., Voisey, K., & McCartney, D. (2018). Effects of pre-cracking on small punch creep testing of a vacuum plasma-sprayed CoNiCrAlY coating. Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications, 232(3), 242-249. https://doi.org/10.1177/1464420715622495

This paper presents the results of small punch creep testing (SPCT) of a vacuum plasma-sprayed (VPS) CoNiCrAlY coating (Co – 31.7%, Ni – 20.8%, Cr – 8.1%, Al – 0.5%, Y, all in wt%) carried out at 750 grad. C. Coating cross-sections, after initial hea... Read More about Effects of pre-cracking on small punch creep testing of a vacuum plasma-sprayed CoNiCrAlY coating.