Skip to main content

Research Repository

Advanced Search

All Outputs (4)

A review of thermal absorbers and their integration methods for the combined solar photovoltaic/thermal (PV/T) modules (2016)
Journal Article
Wu, J., Zhang, X., Shen, J., Wu, Y., Connelly, K., Yang, T., …Wang, H. (in press). A review of thermal absorbers and their integration methods for the combined solar photovoltaic/thermal (PV/T) modules. Renewable and Sustainable Energy Reviews, 75, https://doi.org/10.1016/j.rser.2016.11.063

Thermal absorbers and their integration methods are critical to solar photovoltaic/thermal (PV/T) modules. These two elements directly influence the cooling effort of PV layers and as a result, the related electrical/thermal/overall efficiency. This... Read More about A review of thermal absorbers and their integration methods for the combined solar photovoltaic/thermal (PV/T) modules.

The phase equilibrium and density studies of the ternary mixtures of CO2 + Ar + N2 and CO2 + Ar + H2, systems relevance to CCS technology (2016)
Journal Article
Ke, J., Suleiman, N., Sanchez-Vicente, Y., Murphy, T. S., Rodriguez, J., Ramos, A., …George, M. W. (2017). The phase equilibrium and density studies of the ternary mixtures of CO2 + Ar + N2 and CO2 + Ar + H2, systems relevance to CCS technology. International Journal of Greenhouse Gas Control, 56, 55-66. https://doi.org/10.1016/j.ijggc.2016.11.003

The p-T phase diagrams of two ternary systems (CO2 + Ar + N2 and CO2 + Ar + H2) have been measured at temperatures between 268 and 303 K using a fibre-optic phase equilibrium analyser. CO2, which is the major component, has a mole fraction ranging fr... Read More about The phase equilibrium and density studies of the ternary mixtures of CO2 + Ar + N2 and CO2 + Ar + H2, systems relevance to CCS technology.

An islanding detection method for multi-DG systems based on high-frequency impedance estimation (2016)
Journal Article
Jia, K., Wei, H., Bi, T., Thomas, D. W., & Sumner, M. (2017). An islanding detection method for multi-DG systems based on high-frequency impedance estimation. IEEE Transactions on Sustainable Energy, 8(1), 74-83. https://doi.org/10.1109/TSTE.2016.2582846

Active islanding detection methods are generally employed for grid-connected inverter-based Distributed Generation (DG). However, there might be mutual influences and power quality issues caused by the disturbance signal when multiple inverters are i... Read More about An islanding detection method for multi-DG systems based on high-frequency impedance estimation.

High frequency impedance based fault location in distribution system with DGs (2016)
Journal Article
Jia, K., Bi, T., Ren, Z., Thomas, D. W., & Sumner, M. (2018). High frequency impedance based fault location in distribution system with DGs. IEEE Transactions on Smart Grid, 9(2), 807-816. https://doi.org/10.1109/TSG.2016.2566673

Distributed Generations (DGs) with power electronic devices and their control loops will cause distortion to the fault currents and result in errors for power frequency measurement based fault locations. This might jeopardize the distribution system... Read More about High frequency impedance based fault location in distribution system with DGs.