Skip to main content

Research Repository

Advanced Search

Smart windows—-dynamic control of building energy performance

Allen, Kaitlin; Connelly, Karen; Rutherford, Peter; Wu, Yupeng

Smart windows—-dynamic control of building energy performance Thumbnail


Authors

Kaitlin Allen

Karen Connelly

YUPENG WU yupeng.wu@nottingham.ac.uk
Professor of Building Physics



Abstract

This paper explores the potential of thermotropic (TT) windows as a means of improving overall building energy performance. Capitalising on their ability to dynamically alter solar and visible light transmittance and reflectance based on window temperature, they have the ability to reduce solar heat gains and subsequently reduce cooling loads when the external conditions exceed those required for occupant comfort. Conversely when the external conditions fall short of those required for comfort, they maintain a degree of optical transparency thus promoting opportunities afforded by passive solar gains. To test their overall effectiveness, thermotropic layers made of varying hydroxypropyl cellulose (HPC) concentrations (2 wt.%, 4 wt.% and 6 wt.%) were firstly synthesised and their optical properties measured. Building performance predictions were subsequently conducted in EnergyPlus for four window inclinations (90°, 60°, 30° and 0° to the horizontal) based on a small office test cell situated in the hot summer Mediterranean climate of Palermo, Italy. Results from annual predictions show that both incident solar radiation and outdoor ambient temperature play a significant role in the transmissivity and reflectivity of the glazing unit. If used as a roof light, a 6 wt.% HPC-based thermotropic window has a dynamic average Solar Heat Gain Coefficient (SHGC) between 0.44 and 0.56, this lower than that of 0.74 for double glazing. Predictions also show that in the specific case tested, the 6 wt.% HPC-based thermotropic window provides an overall annual energy saving of 22% over an equivalent double glazed unit. By maintaining the thermotropic window spectral properties but lowering the associated transition temperature ranges, it was found that the lowest temperature range provided the smallest solar heat gains. Although, this is beneficial during periods where cooling may be needed, in those periods where heating may be required, opportunities gained through passive solar heating are limited. In addition, with lower solar heat gain, there is a possibility that artificial lighting energy demand increases resulting in additional energy consumption.

Citation

Allen, K., Connelly, K., Rutherford, P., & Wu, Y. (2017). Smart windows—-dynamic control of building energy performance. Energy and Buildings, 139, https://doi.org/10.1016/j.enbuild.2016.12.093

Journal Article Type Article
Acceptance Date Dec 30, 2016
Online Publication Date Jan 5, 2017
Publication Date Mar 15, 2017
Deposit Date Apr 10, 2017
Publicly Available Date Apr 10, 2017
Journal Energy and Buildings
Print ISSN 0378-7788
Electronic ISSN 1872-6178
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 139
DOI https://doi.org/10.1016/j.enbuild.2016.12.093
Keywords Thermotropic window; Smart window; Hydroxypropyl cellulose (HPC); Building simulation; Solar heat gain coefficient
Public URL https://nottingham-repository.worktribe.com/output/850216
Publisher URL http://www.sciencedirect.com/science/article/pii/S0378778816320783
Contract Date Apr 10, 2017

Files





You might also like