Skip to main content

Research Repository

Advanced Search

All Outputs (3)

The impact of thermal insulation on cooling energy consumption and optimal insulation thickness for underground tunnel (2021)
Journal Article
Wang, Y., Wang, C., Gao, S., Zheng, X., & Darkwa, J. (2021). The impact of thermal insulation on cooling energy consumption and optimal insulation thickness for underground tunnel. Sustainable Energy Technologies and Assessments, 47, Article 101495. https://doi.org/10.1016/j.seta.2021.101495

The provision of mechanical cooling in deep mines comes with a significant energy cost as a significant amount of heat transfers from surrounding rock to the airflow. Thermal insulation can be applied to reduce such heat transfer, thereby cutting dow... Read More about The impact of thermal insulation on cooling energy consumption and optimal insulation thickness for underground tunnel.

Experimental investigation on performance improvement of thermoelectric generator based on phase change materials and heat transfer enhancement (2021)
Journal Article
Wang, Y., Peng, Y., Guo, K., Zheng, X., Darkwa, J., & Zhong, H. (2021). Experimental investigation on performance improvement of thermoelectric generator based on phase change materials and heat transfer enhancement. Energy, 229, Article 120676. https://doi.org/10.1016/j.energy.2021.120676

Thermoelectric application has been widely researched due to its various advantages. Its use has been limited to niche industrial applications and exploratory research development due to the poor economic viability. It is essential to achieve the opt... Read More about Experimental investigation on performance improvement of thermoelectric generator based on phase change materials and heat transfer enhancement.

Evaluation of the indoor pressure distribution during building airtightness tests using the pulse and blower door methods (2021)
Journal Article
Hsu, Y., Zheng, X., Cooper, E., Gillott, M., & Wood, C. J. (2021). Evaluation of the indoor pressure distribution during building airtightness tests using the pulse and blower door methods. Building and Environment, 195, Article 107742. https://doi.org/10.1016/j.buildenv.2021.107742

Building airtightness is a critical aspect for energy-efficient buildings as the energy performance of a building can be significantly reduced by poor airtightness. The Pulse technique has been regarded as a promising technology, measuring building a... Read More about Evaluation of the indoor pressure distribution during building airtightness tests using the pulse and blower door methods.