Dylan H. Jones
Preparation, Scanning and Analysis of Duckweed Using X-Ray Computed Microtomography
Jones, Dylan H.; Atkinson, Brian; Ware, Alexander; Sturrock, Craig J.; Bishopp, Anthony; Wells, Darren M.
Authors
Brian Atkinson
Mr ALEX WARE ALEX.WARE@NOTTINGHAM.AC.UK
BBSRC Discovery Fellow
Dr CRAIG STURROCK craig.sturrock@nottingham.ac.uk
PRINCIPAL RESEARCH FELLOW
Professor ANTHONY BISHOPP Anthony.Bishopp@nottingham.ac.uk
PROFESSOR OF PLANT DEVELOPMENT BIOLOGY
Dr DARREN WELLS DARREN.WELLS@NOTTINGHAM.AC.UK
PRINCIPAL RESEARCH FELLOW
Abstract
© Copyright © 2021 Jones, Atkinson, Ware, Sturrock, Bishopp and Wells. Quantification of anatomical and compositional features underpins both fundamental and applied studies of plant structure and function. Relatively few non-invasive techniques are available for aquatic plants. Traditional methods such as sectioning are low-throughput and provide 2-dimensional information. X-ray Computed Microtomography (μCT) offers a non-destructive method of three dimensional (3D) imaging in planta, but has not been widely used for aquatic species, due to the difficulties in sample preparation and handling. We present a novel sample handling protocol for aquatic plant material developed for μCT imaging, using duckweed plants and turions as exemplars, and compare the method against existing approaches. This technique allows for previously unseen 3D volume analysis of gaseous filled spaces, cell material, and sub-cellular features. The described embedding method, utilizing petrolatum gel for sample mounting, was shown to preserve sample quality during scanning, and to display sufficiently different X-ray attenuation to the plant material to be easily differentiated by image analysis pipelines. We present this technique as an improved method for anatomical structural analysis that provides novel cellular and developmental information.
Citation
Jones, D. H., Atkinson, B., Ware, A., Sturrock, C. J., Bishopp, A., & Wells, D. M. (2021). Preparation, Scanning and Analysis of Duckweed Using X-Ray Computed Microtomography. Frontiers in Plant Science, 11, Article 617830. https://doi.org/10.3389/fpls.2020.617830
Journal Article Type | Article |
---|---|
Acceptance Date | Dec 7, 2020 |
Online Publication Date | Jan 8, 2021 |
Publication Date | Jan 8, 2021 |
Deposit Date | Dec 16, 2020 |
Publicly Available Date | Jan 8, 2021 |
Journal | Frontiers in Plant Science |
Electronic ISSN | 1664-462X |
Publisher | Frontiers Media |
Peer Reviewed | Peer Reviewed |
Volume | 11 |
Article Number | 617830 |
DOI | https://doi.org/10.3389/fpls.2020.617830 |
Keywords | duckweed; MicroCT (mCT) scanning technology; anatomics; image analysis; petrolatum; anatomical phenotyping |
Public URL | https://nottingham-repository.worktribe.com/output/5153159 |
Publisher URL | https://www.frontiersin.org/articles/10.3389/fpls.2020.617830/full |
Additional Information | Jones DH, Atkinson BS, Ware A, Sturrock CJ, Bishopp A and Wells DM (2021) Preparation, Scanning and Analysis of Duckweed Using X-Ray Computed Microtomography. Front. Plant Sci. 11:617830. doi: 10.3389/fpls.2020.617830 |
Files
Preparation, Scanning and Analysis of Duckweed Using X-Ray Computed Microtomography
(6 Mb)
PDF
You might also like
The first intron of ARF7 is required for expression in root tips
(2024)
Journal Article
The evolution of the duckweed ionome mirrors losses in structural complexity
(2024)
Journal Article