Maria Camporesi
Development, Implementation and Testing of a Multicellular Dynamic Action Potential Clamp Simulator for Drug Cardiac Safety Assessment
Camporesi, Maria; Bartolucci, Chiara; Lei, Chon Lok; Mirams, Gary R.; De Boer, Teun P.; Severi, Stefano
Authors
Chiara Bartolucci
Chon Lok Lei
Professor GARY MIRAMS GARY.MIRAMS@NOTTINGHAM.AC.UK
PROFESSOR OF MATHEMATICAL BIOLOGY
Teun P. De Boer
Stefano Severi
Abstract
© 2020 Creative Commons; the authors hold their copyright. As drugs can be multichannel blockers it is important to assess their cardiac safety taking into account multiple currents. In silico action potential (AP) models have been proposed for being able to integrate drugs effect on ionic currents and generate the resulting AP. However, a mathematical description of drug effects is required, which could be inaccurate. Dynamic Clamp has been proposed for drug cardiac safety assessment. In the dynamic action potential clamp (dAPC) configuration it creates an hybrid model connecting a real cell with a computer simulation. This way, drugs could be administrated directly to real cells, and effects on currents can be taken into account when generating the AP. Here we design and simulate a parallel multichannel dAPC system. The system includes the real cells overexpressing the currents of interest, the voltage clamp acquisition system, and the AP in silico model.
Citation
Camporesi, M., Bartolucci, C., Lei, C. L., Mirams, G. R., De Boer, T. P., & Severi, S. (2020, September). Development, Implementation and Testing of a Multicellular Dynamic Action Potential Clamp Simulator for Drug Cardiac Safety Assessment. Presented at Computing in Cardiology, Rimini, Italy
Presentation Conference Type | Conference Paper (published) |
---|---|
Conference Name | Computing in Cardiology |
Start Date | Sep 13, 2020 |
End Date | Sep 16, 2020 |
Acceptance Date | Sep 13, 2020 |
Publication Date | Sep 16, 2020 |
Deposit Date | Dec 22, 2021 |
Publicly Available Date | Jan 6, 2022 |
Publisher | Institute of Electrical and Electronics Engineers |
Volume | 47 (2020) |
ISBN | 9781728173825 |
DOI | https://doi.org/10.22489/CinC.2020.416 |
Public URL | https://nottingham-repository.worktribe.com/output/5376550 |
Publisher URL | https://www.cinc.org/archives/2020/pdf/CinC2020-416.pdf |
Related Public URLs | https://cinc.org/archives/2020/ |
Files
Camporesi-et-al-2020 Dynamic Clamp Simulation With Artefacts CinC
(348 Kb)
PDF
Publisher Licence URL
https://creativecommons.org/licenses/by/4.0/
You might also like
Ten simple rules for training scientists to make better software
(2024)
Journal Article
Geometrically-derived action potential markers for model development: a principled approach?
(2024)
Preprint / Working Paper
Optimising experimental designs for model selection of ion channel drug binding mechanisms
(2024)
Preprint / Working Paper
Evaluating the predictive accuracy of ion channel models using data from multiple experimental designs
(2024)
Preprint / Working Paper
A range of voltage-clamp protocol designs for rapid capture of hERG kinetics
(2024)
Preprint / Working Paper
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search