Skip to main content

Research Repository

Advanced Search

Volumetric error modelling of a stereo vision system for error correction in photogrammetric three-dimensional coordinate metrology

Isa, Mohammed A.; Sims-Waterhouse, Danny; Piano, Samanta; Leach, Richard

Volumetric error modelling of a stereo vision system for error correction in photogrammetric three-dimensional coordinate metrology Thumbnail


Authors

Danny Sims-Waterhouse



Abstract

Optical three-dimensional coordinate measurement using stereo vision has systematic errors that affect measurement quality. This paper presents a scheme for measuring, modelling and correcting these errors. The position and orientation of a linear stage are measured with a laser interferometer while a stereo vision system tracks target points on the moving stage. With reference to the higher accuracy laser interferometer measurement, the displacement errors of the tracked points are evaluated. Regression using a neural network is used to generate a volumetric error model from the evaluated displacement errors. The regression model is shown to outperform other interpolation methods. The volumetric error model is validated by correcting the three-dimensional coordinates of the point cloud from a photogrammetry instrument that uses the stereo vision system. The corrected points from the measurement of a calibrated spherical artefact are shown to have size and form errors of less than 50 μm and 110 μm respectively. A reduction of up to 30% in the magnitude of the probing size error is observed after error correction is applied.

Citation

Isa, M. A., Sims-Waterhouse, D., Piano, S., & Leach, R. (2020). Volumetric error modelling of a stereo vision system for error correction in photogrammetric three-dimensional coordinate metrology. Precision Engineering, 64, 188-199. https://doi.org/10.1016/j.precisioneng.2020.04.010

Journal Article Type Article
Acceptance Date Apr 13, 2020
Online Publication Date Apr 20, 2020
Publication Date 2020-07
Deposit Date Apr 28, 2020
Publicly Available Date Apr 21, 2021
Journal Precision Engineering
Print ISSN 0141-6359
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 64
Pages 188-199
DOI https://doi.org/10.1016/j.precisioneng.2020.04.010
Public URL https://nottingham-repository.worktribe.com/output/4354981
Publisher URL https://www.sciencedirect.com/science/article/abs/pii/S0141635919309365?via%3Dihub
Additional Information This article is maintained by: Elsevier; Article Title: Volumetric error modelling of a stereo vision system for error correction in photogrammetric three-dimensional coordinate metrology; Journal Title: Precision Engineering; CrossRef DOI link to publisher maintained version: https://doi.org/10.1016/j.precisioneng.2020.04.010; Content Type: article; Copyright: © 2020 Elsevier Inc. All rights reserved.