Dr JAMES SHARP james.sharp@nottingham.ac.uk
ASSOCIATE PROFESSOR
Telephone cord blister formation in solvent swollen elastomer films
Sharp, James S.; Roberts, Nathaniel M.; Walker, Sam
Authors
Nathaniel M. Roberts
Sam Walker
Abstract
Video imaging was used to study large-slope folded telephone cord blister formation in solvent swollen films of polydimethylsiloxane (PDMS) elastomers. Chlorobenzene, chloroform, heptane and toluene were used to swell PDMS films with thickness values in the range 15 μm < h < 223 μm supported on glass substrates. Measurements of the blister width, corrugation wavelength and blister growth speed were studied as a function of the film thickness for all four solvents. Modified theories of buckling were shown to accurately predict the film thickness dependence of the width and corrugation wavelength and a modified fracture mechanics approach was shown to reproduce the non-monotonic thickness dependence of the blister growth rates. Two critical thickness values were identified for telephone cord blisters formed on solvent swollen PDMS films-one corresponding to a lower critical thickness for blistering and the other corresponding to a peak in the thickness dependent blister growth rates. Blister formation is shown to be consistent with the existence of mixed modality in the growth of the crack tip at the film-substrate interface. Both critical thickness values are shown to depend upon the strength of the adhesive interactions between the film and the substrate and the Young's modulus of the films. A simple method of patterning surfaces with telephone cord blisters is also introduced.
Citation
Sharp, J. S., Roberts, N. M., & Walker, S. (2024). Telephone cord blister formation in solvent swollen elastomer films. Soft Matter, 20(44), 8812-8823. https://doi.org/10.1039/d4sm01035c
Journal Article Type | Article |
---|---|
Acceptance Date | Oct 19, 2024 |
Online Publication Date | Oct 21, 2024 |
Publication Date | Nov 28, 2024 |
Deposit Date | Nov 4, 2024 |
Publicly Available Date | Nov 11, 2024 |
Journal | Soft Matter |
Print ISSN | 1744-683X |
Electronic ISSN | 1744-6848 |
Publisher | Royal Society of Chemistry |
Peer Reviewed | Peer Reviewed |
Volume | 20 |
Issue | 44 |
Pages | 8812-8823 |
DOI | https://doi.org/10.1039/d4sm01035c |
Public URL | https://nottingham-repository.worktribe.com/output/41369133 |
Publisher URL | https://pubs.rsc.org/en/content/articlelanding/2024/sm/d4sm01035c |
Files
Telephone Cord Blister Formation In Solvent Swollen Elastomer Films
(4.1 Mb)
PDF
Licence
https://creativecommons.org/licenses/by-nc/3.0/
Publisher Licence URL
https://creativecommons.org/licenses/by-nc/3.0/
You might also like
Piezoelectric excitation and acoustic detection of thin film polymer membrane vibrations
(2024)
Journal Article
Imaging mass spectrometry of fingermarks on brass bullet casings using sample rotation
(2021)
Journal Article
The emergence of local wrinkling or global buckling in thin freestanding bilayer films
(2020)
Journal Article
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search