Professor CORINE VERHOEVEN C.Verhoeven@nottingham.ac.uk
PROFESSOR OF MIDWIFERY
Transvaginal sonographic assessment of cervical length and wedging for predicting outcome of labor induction at term: A systematic review and meta-analysis
Verhoeven, C.J.M.; Opmeer, B.C.; Oei, S.G.; Latour, V.; van der Post, J.A.M.; Mol, B.W.J.
Authors
B.C. Opmeer
S.G. Oei
V. Latour
J.A.M. van der Post
B.W.J. Mol
Abstract
Objective
To perform a systematic review and meta-analysis to assess the predictive capacity of transvaginal sonographic assessment of the cervix for the outcome of induction of labor.
Methods
We searched MEDLINE, EMBASE and the Cochrane Library, and manually searched reference lists of review articles and eligible primary articles. Studies in all languages were eligible if published in full. Two reviewers independently selected studies and extracted data on study characteristics, quality and test accuracy. We then calculated pooled sensitivities and specificities (with 95% CIs) and summary receiver–operating characteristics (sROC) curves. Outcome measures were test accuracy of sonographically measured cervical length and cervical wedging for Cesarean section, not achieving vaginal delivery within 24 h and not achieving active labor.
Results
We included 31 studies reporting on both cervical length and outcome of delivery. The quality of the included studies was mediocre. Sensitivity of cervical length in the prediction of Cesarean delivery ranged from 0.14 to 0.92 and specificity ranged from 0.35 to 1.00. The estimated sROC curve for cervical length indicated a limited predictive capacity in the prediction of Cesarean delivery. Summary estimates of sensitivity/specificity combinations of cervical length at different cut-offs for Cesarean delivery were 0.82/0.34, 0.64/0.74 and 0.13/0.95 for 20, 30 and 40 mm, respectively. For cervical wedging in the prediction of failed induction of labor summary point estimates of sensitivity/specificity were 0.37/0.80.
Conclusions
Cervical length and cervical wedging as measured sonographically at or near term have moderate capacity to predict the outcome of delivery after induction of labor.
Citation
Verhoeven, C., Opmeer, B., Oei, S., Latour, V., van der Post, J., & Mol, B. (2013). Transvaginal sonographic assessment of cervical length and wedging for predicting outcome of labor induction at term: A systematic review and meta-analysis. Ultrasound in Obstetrics & Gynecology, 42(5), 500-508. https://doi.org/10.1002/uog.12467
Journal Article Type | Article |
---|---|
Acceptance Date | Mar 14, 2013 |
Online Publication Date | Mar 26, 2013 |
Publication Date | 2013-11 |
Deposit Date | Aug 6, 2023 |
Journal | Ultrasound in Obstetrics and Gynecology |
Print ISSN | 1469-0705 |
Publisher | Wiley |
Peer Reviewed | Peer Reviewed |
Volume | 42 |
Issue | 5 |
Pages | 500-508 |
DOI | https://doi.org/10.1002/uog.12467 |
Public URL | https://nottingham-repository.worktribe.com/output/23513724 |
Publisher URL | https://obgyn.onlinelibrary.wiley.com/doi/10.1002/uog.12467 |
You might also like
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search