Skip to main content

Research Repository

Advanced Search

All Outputs (76)

The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG study (2024)
Journal Article
Rier, L., Rhodes, N., Pakenham, D., Boto, E., Holmes, N., Hill, R. M., …Brookes, M. J. (2024). The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG study. eLife, Article 94561v1. https://doi.org/10.7554/eLife.94561.1

Neural oscillations mediate coordination of activity within and between brain networks, supporting cognition and behaviour. How these processes develop throughout childhood is not only a critical neuroscientific question but could also shed light on... Read More about The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG study.

Designing Optimal Loop, Saddle, and Ellipse-Based Magnetic Coils by Spherical Harmonic Mapping (2023)
Journal Article
Hobson, P. J., Hardwicke, N. L., Davis, A., Smith, T. X., Morley, C., Packer, M., …Fromhold, M. (2023). Designing Optimal Loop, Saddle, and Ellipse-Based Magnetic Coils by Spherical Harmonic Mapping. IEEE Transactions on Instrumentation and Measurement, 72, Article 1005815. https://doi.org/10.1109/TIM.2023.3284138

Adaptable, low-cost, coils designed by carefully selecting the arrangements and geometries of simple primitive units are used to generate magnetic fields for diverse applications. These extend from magnetic resonance and fundamental physics experimen... Read More about Designing Optimal Loop, Saddle, and Ellipse-Based Magnetic Coils by Spherical Harmonic Mapping.

Test-retest reliability of the human connectome: An OPM-MEG study (2023)
Journal Article
Rier, L., Michelmann, S., Ritz, H., Shah, V., Hill, R. M., Osborne, J., …Boto, E. (2023). Test-retest reliability of the human connectome: An OPM-MEG study. Imaging Neuroscience, 1, 1-20. https://doi.org/10.1162/imag_a_00020

Magnetoencephalography with optically pumped magnetometers (OPM-MEG) offers a new way to record electrophysiological brain function, with significant advantages over conventional MEG, including adaptability to head shape/size, free movement during sc... Read More about Test-retest reliability of the human connectome: An OPM-MEG study.

The impact of variations in subject geometry, respiration and coil repositioning on the specific absorption rate in parallel transmit abdominal imaging at 7 T (2023)
Journal Article
Doran, E., Naim, I., Bowtell, R., Gowland, P. A., Glover, P. M., & Bawden, S. (in press). The impact of variations in subject geometry, respiration and coil repositioning on the specific absorption rate in parallel transmit abdominal imaging at 7 T. NMR in Biomedicine, Article e5032. https://doi.org/10.1002/nbm.5032

Parallel transmit MRI at 7 T has increasingly been adopted in research projects and provides increased signal‐to‐noise ratios and novel contrasts. However, the interactions of fields in the body need to be carefully considered to ensure safe scanning... Read More about The impact of variations in subject geometry, respiration and coil repositioning on the specific absorption rate in parallel transmit abdominal imaging at 7 T.

Benchtop magnetic shielding for benchmarking atomic magnetometers (2023)
Journal Article
Hobson, P. J., Holmes, N., Patel, P., Styles, B., Chalmers, J., Morley, C., …Fromhold, M. (2023). Benchtop magnetic shielding for benchmarking atomic magnetometers. IEEE Transactions on Instrumentation and Measurement, 72, Article 6007309. https://doi.org/10.1109/tim.2023.3293540

Here, a benchtop hybrid magnetic shield containing four mumetal cylinders and nine internal flexible printed circuit boards is designed, constructed, tested, and operated. The shield is designed specifically as a test-bed for building and operating u... Read More about Benchtop magnetic shielding for benchmarking atomic magnetometers.

An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts (2023)
Journal Article
Holmes, N., Bowtell, R., Brookes, M. J., & Taulu, S. (2023). An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts. Sensors, 23(14), Article 6537. https://doi.org/10.3390/s23146537

The signal space separation (SSS) method is routinely employed in the analysis of multichannel magnetic field recordings (such as magnetoencephalography (MEG) data). In the SSS method, signal vectors are posed as a multipole expansion of the magnetic... Read More about An Iterative Implementation of the Signal Space Separation Method for Magnetoencephalography Systems with Low Channel Counts.

Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023)
Journal Article
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., …Bowtell, R. (2023). Naturalistic Hyperscanning with Wearable Magnetoencephalography. Sensors, 23(12), Article 5454. https://doi.org/10.3390/s23125454

The evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substra... Read More about Naturalistic Hyperscanning with Wearable Magnetoencephalography.

Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding (2023)
Journal Article
Holmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., …Bowtell, R. (2023). Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding. NeuroImage, 274, Article 120157. https://doi.org/10.1016/j.neuroimage.2023.120157

The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to... Read More about Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding.

Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers (2023)
Journal Article
Hillebrand, A., Holmes, N., Sijsma, N., O’Neill, G. C., Tierney, T. M., Liberton, N., …Barnes, G. R. (2023). Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers. Scientific Reports, 13(1), Article 4623. https://doi.org/10.1038/s41598-023-31111-y

Magneto- and electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio... Read More about Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers.

Measurement of Frontal Midline Theta Oscillations using OPM-MEG (2023)
Journal Article
Rhodes, N., Rea, M., Boto, E., Rier, L., Shah, V., Hill, R. M., …Brookes, M. J. (2023). Measurement of Frontal Midline Theta Oscillations using OPM-MEG. NeuroImage, 271, Article 120024. https://doi.org/10.1016/j.neuroimage.2023.120024

Optically pumped magnetometers (OPMs) are an emerging lightweight and compact sensor that can measure magnetic fields generated by the human brain. OPMs enable construction of wearable magnetoencephalography (MEG) systems, which offer advantages over... Read More about Measurement of Frontal Midline Theta Oscillations using OPM-MEG.

Deuterium brain imaging at 7T during D2O dosing (2022)
Journal Article
Cocking, D., Damion, R. A., Franks, H., Jaconelli, M., Wilkinson, D., Brook, M., …Bowtell, R. (2023). Deuterium brain imaging at 7T during D2O dosing. Magnetic Resonance in Medicine, 89(4), 1514-1521. https://doi.org/10.1002/mrm.29539

Purpose To characterize the (2H) deuterium MR signal measured from human brain at 7T in participants loading with D2O to ˜1.5% enrichment over a six-week period. Methods 2H spectroscopy and imaging measurements were used to track the time-course... Read More about Deuterium brain imaging at 7T during D2O dosing.

Improved Dynamic Contrast-Enhanced MRI Using Low Rank with Joint Sparsity (2022)
Journal Article
Zhang, J., Najeeb, F., Wang, X., Xu, P., Omer, H., Zheng, J., …Wang, C. (2022). Improved Dynamic Contrast-Enhanced MRI Using Low Rank with Joint Sparsity. IEEE Access, 10, 121193-121203. https://doi.org/10.1109/access.2022.3222313

This work presents a free-breathing dynamic contrast-enhanced (DCE) MRI reconstruction method called low-rank plus sparse (L+S) with joint sparsity. The proposed method improved dynamic contrast performance by integrating an additional temporal Fast... Read More about Improved Dynamic Contrast-Enhanced MRI Using Low Rank with Joint Sparsity.

Chronic neuropsychiatric sequelae of SARS-CoV-2: Protocol and methods from the Alzheimer's Association Global Consortium (2022)
Journal Article
de Erausquin, G. A., Snyder, H., Brugha, T. S., Seshadri, S., Carrillo, M., Sagar, R., …Vahidy, F. S. (2022). Chronic neuropsychiatric sequelae of SARS-CoV-2: Protocol and methods from the Alzheimer's Association Global Consortium. Alzheimer's and Dementia: Translational Research and Clinical Interventions, 8(1), Article e12348. https://doi.org/10.1002/trc2.12348

Introduction: Coronavirus disease 2019 (COVID-19) has caused >3.5 million deaths worldwide and affected >160 million people. At least twice as many have been infected but remained asymptomatic or minimally symptomatic. COVID-19 includes central nervo... Read More about Chronic neuropsychiatric sequelae of SARS-CoV-2: Protocol and methods from the Alzheimer's Association Global Consortium.

Turning OPM-MEG into a Wearable Technology (2022)
Book Chapter
Rhodes, N., Holmes, N., Hill, R., Barnes, G., Bowtell, R., Brookes, M., & Boto, E. (2022). Turning OPM-MEG into a Wearable Technology. In E. Labyt, T. Sander, & R. Wakai (Eds.), Flexible High Performance Magnetic Field Sensors: On-Scalp Magnetoencephalography and Other Applications (195-223). Springer International Publishing. https://doi.org/10.1007/978-3-031-05363-4_11

This chapter explores the use of optically pumped magnetometers (OPMs) as a tool for magnetoencephalography (MEG). Conventional MEG systems use superconducting quantum interference devices (SQUIDs) to measure the femto-Tesla-level magnetic fields at... Read More about Turning OPM-MEG into a Wearable Technology.

A lightweight magnetically shielded room with active shielding (2022)
Journal Article
Holmes, N., Rea, M., Chalmers, J., Leggett, J., Edwards, L. J., Nell, P., …Bowtell, R. (2022). A lightweight magnetically shielded room with active shielding. Scientific Reports, 12, Article 13561. https://doi.org/10.1038/s41598-022-17346-1

Magnetically shielded rooms (MSRs) use multiple layers of materials such as MuMetal to screen external magnetic fields that would otherwise interfere with high precision magnetic field measurements such as magnetoencephalography (MEG). Optically pump... Read More about A lightweight magnetically shielded room with active shielding.

A global survey of healthcare professionals undertaking MRI of patients with cochlear implants: a heterogeneity of practice and opinions (2022)
Journal Article
Dewey, R. S., Bowtell, R., & Kitterick, P. (2022). A global survey of healthcare professionals undertaking MRI of patients with cochlear implants: a heterogeneity of practice and opinions. British Journal of Radiology, 95(1137), Article 20220213. https://doi.org/10.1259/bjr.20220213

Objective: To capture practice and opinions around the current clinical use of MRI in patients with cochlear implants (CIs), and to characterise patient progression from referral to image reporting. Methods: An online survey recruited 237 healthcare... Read More about A global survey of healthcare professionals undertaking MRI of patients with cochlear implants: a heterogeneity of practice and opinions.

Bespoke magnetic field design for a magnetically shielded cold atom interferometer (2022)
Journal Article
Hobson, P. J., Vovrosh, J., Stray, B., Packer, M., Winch, J., Holmes, N., …Holynski, M. (2022). Bespoke magnetic field design for a magnetically shielded cold atom interferometer. Scientific Reports, 12(1), Article 10520. https://doi.org/10.1038/s41598-022-13979-4

Quantum sensors based on cold atoms are being developed which produce measurements of unprecedented accuracy. Due to shifts in atomic energy levels, quantum sensors often have stringent requirements on their internal magnetic field environment. Typic... Read More about Bespoke magnetic field design for a magnetically shielded cold atom interferometer.

Phenotypic and genetic associations of quantitative magnetic susceptibility in UK Biobank brain imaging (2022)
Journal Article
Wang, C., Martins-Bach, A. B., Alfaro-Almagro, F., Douaud, G., Klein, J. C., Llera, A., …Miller, K. L. (2022). Phenotypic and genetic associations of quantitative magnetic susceptibility in UK Biobank brain imaging. Nature Neuroscience, 25(6), 818-831. https://doi.org/10.1038/s41593-022-01074-w

A key aim in epidemiological neuroscience is identification of markers to assess brain health and monitor therapeutic interventions. Quantitative susceptibility mapping (QSM) is an emerging magnetic resonance imaging technique that measures tissue ma... Read More about Phenotypic and genetic associations of quantitative magnetic susceptibility in UK Biobank brain imaging.

Using OPM-MEG in contrasting magnetic environments (2022)
Journal Article
Hill, R. M., Devasagayam, J., Holmes, N., Boto, E., Shah, V., Osborne, J., …Brookes, M. J. (2022). Using OPM-MEG in contrasting magnetic environments. NeuroImage, 253, Article 119084. https://doi.org/10.1016/j.neuroimage.2022.119084

Magnetoencephalography (MEG) has been revolutionised by optically pumped magnetometers (OPMs). “OPM-MEG” offers higher sensitivity, better spatial resolution, and lower cost than conventional instrumentation based on superconducting quantum interfere... Read More about Using OPM-MEG in contrasting magnetic environments.

Magnetic field design in a cylindrical high-permeability shield: The combination of simple building blocks and a genetic algorithm (2022)
Journal Article
Packer, M., Hobson, P. J., Davis, A., Holmes, N., Leggett, J., Glover, P., …Fromhold, T. M. (2022). Magnetic field design in a cylindrical high-permeability shield: The combination of simple building blocks and a genetic algorithm. Journal of Applied Physics, 131(9), Article 093902. https://doi.org/10.1063/5.0071986

Magnetically sensitive experiments and newly developed quantum technologies with integrated high-permeability magnetic shields require increasing control of their magnetic field environment and reductions in size, weight, power, and cost. However, ma... Read More about Magnetic field design in a cylindrical high-permeability shield: The combination of simple building blocks and a genetic algorithm.