A component method model for blind-bolts with headed anchors in tension (2015)
Journal Article
Pitrakkos, T., & Tizani, W. (2015). A component method model for blind-bolts with headed anchors in tension. Steel and Composite Structures, 18(5), 1305-1330. https://doi.org/10.12989/scs.2015.18.5.1305

Copyright © 2015 Techno-Press, Ltd. The successful application of the component-based approach - widely used to model structural joints - requires knowledge of the mechanical properties of the constitutive joint components, including an appropriate a... Read More about A component method model for blind-bolts with headed anchors in tension.

Fire performance of blind-bolted connections to concrete filled tubular columns in tension (2015)
Journal Article
Pascual, A. M., Romero, M., & Tizani, W. (2015). Fire performance of blind-bolted connections to concrete filled tubular columns in tension. Engineering Structures, 96, https://doi.org/10.1016/j.engstruct.2015.03.067

This paper describes an advanced numerical model to predict the fire behaviour of blind-bolts in the tension area of endplate connections between I-beams and concrete filled tubular (CFT) columns. It is the continuation of a previous research on the... Read More about Fire performance of blind-bolted connections to concrete filled tubular columns in tension.

Thermal behaviour of blind-bolted connections to hollow and concrete-filled steel tubular columns (2015)
Journal Article
Pascual, A. M., Romero, M., & Tizani, W. (2015). Thermal behaviour of blind-bolted connections to hollow and concrete-filled steel tubular columns. Journal of Constructional Steel Research, 107, https://doi.org/10.1016/j.jcsr.2015.01.014

This paper reports on the thermal analysis of blind-bolts connected to concrete filled steel tube (CFST) and hollow steel section (HSS) columns. The aim is therefore the investigation of the temperature distribution in the connected sections and the... Read More about Thermal behaviour of blind-bolted connections to hollow and concrete-filled steel tubular columns.

BIM extension for the sustainability appraisal of conceptual steel design (2015)
Journal Article
Oti, A. H., & Tizani, W. (2015). BIM extension for the sustainability appraisal of conceptual steel design. Advanced Engineering Informatics, 29, https://doi.org/10.1016/j.aei.2014.09.001

Contemporary advancements in Information Technology and the efforts from various research initiatives in the AEC industry are showing evidence of progress with the emergence of building information mod- elling (BIM). BIM presents the opportunity of e... Read More about BIM extension for the sustainability appraisal of conceptual steel design.

Performance of T-stub to CFT joints using blind bolts with headed anchors (2015)
Journal Article
Tizani, W., & Pitrakkos, T. (2015). Performance of T-stub to CFT joints using blind bolts with headed anchors. Journal of Structural Engineering, 141(10), https://doi.org/10.1061/%28ASCE%29ST.1943-541X.0001169

This paper assesses the performance of a newly developed blind bolt, intended for use in constructing bolted moment-resisting connections to concrete-filled tubular steel profiles. A total of ten connection tests are reported, with each configuration... Read More about Performance of T-stub to CFT joints using blind bolts with headed anchors.