Skip to main content

Research Repository

Advanced Search

All Outputs (13)

Identifying Variation in the Newborn Life Support Procedure: An Automated Method (2023)
Conference Proceeding
Tan, A., Remenyte-Prescott, R., Egede, J., Valstar, M., & Sharkey, D. (2023). Identifying Variation in the Newborn Life Support Procedure: An Automated Method. In M. P. Brito, T. Aven, P. Baraldi, M. Čepin, & E. Zio (Eds.), Proceedings of the 33rd European Safety and Reliability Conference (ESREL 2023) (607-614)

This research is conducted for developing an automated method to recognize variations in the Newborn Life Support (NLS) procedure. Compliance with the NLS standard guideline is essential to prevent any adverse consequences for the newborn. Video reco... Read More about Identifying Variation in the Newborn Life Support Procedure: An Automated Method.

A modelling approach to studying variations in newborn life support procedure (2023)
Journal Article
Tan, A., Remenyte-Prescott, R., Valstar, M., & Sharkey, D. (2023). A modelling approach to studying variations in newborn life support procedure. Proceedings of the Institution of Mechanical Engineers, Part O: Journal of Risk and Reliability, https://doi.org/10.1177/1748006X231173595

Variations in clinical practice are common. However, some variations may cause undesired consequences. Careful consideration of their causes and effects is necessary to assure the quality of healthcare delivery. A modelling approach that could captur... Read More about A modelling approach to studying variations in newborn life support procedure.

Forehead monitoring of heart rate in neonatal intensive care (2023)
Journal Article
Stockwell, S. J., Kwok, T. C., Morgan, S. P., Sharkey, D., & Hayes-Gill, B. R. (2023). Forehead monitoring of heart rate in neonatal intensive care. Frontiers in Physiology, 14, Article 1127419. https://doi.org/10.3389/fphys.2023.1127419

Heart rate is an extremely important physiological parameter to measure in critically unwell infants, as it is the main physiological marker that changes in response to a change in infant condition. Heart rate is routinely measured peripherally on a... Read More about Forehead monitoring of heart rate in neonatal intensive care.

Modelling Variations in Newborn Life Support Procedure Using Colored Petri Nets (2022)
Conference Proceeding
Leva, M. C., Patelli, E., Podofillini, L., Wilson, S., Tan, A., Remenyte-Prescott, R., …Sharkey, D. (2022). Modelling Variations in Newborn Life Support Procedure Using Colored Petri Nets. In M. Chiara Leva, E. Patelli, L. Podofillini, & S. Wilson (Eds.), Proceedings of the 32nd European Safety and Reliability Conference (ESREL 2022) (489-496). https://doi.org/10.3850/978-981-18-5183-4_R12-08-152-cd

This research is conducted to study variations in the Newborn Life Support procedure. This procedure follows an evidence-based protocol to resuscitate and stabilize newborn babies requiring assistance at birth. Errors and ineffective actions in this... Read More about Modelling Variations in Newborn Life Support Procedure Using Colored Petri Nets.

Feasibility of a Novel ECG Electrode Placement Method in Newborn Infants (2022)
Journal Article
Henry, C., Shipley, L., Morgan, S., Crowe, J. A., Carpenter, J., Hayes-Gill, B., & Sharkey, D. (2022). Feasibility of a Novel ECG Electrode Placement Method in Newborn Infants. Neonatology, 119(2), 264-267. https://doi.org/10.1159/000521530

Background: International newborn resuscitation guidelines recommend electrocardiogram (ECG) heart rate (HR) monitoring at birth. We evaluated the application time of pre-set ECG electrodes fixed to a polyethene patch allowing adhesive-free attachmen... Read More about Feasibility of a Novel ECG Electrode Placement Method in Newborn Infants.

Smartphone monitoring of in-ambulance vibration and noise (2021)
Journal Article
Partridge, T., Gherman, L., Morris, D., Light, R., Leslie, A., Sharkey, D., …Crowe, J. (2021). Smartphone monitoring of in-ambulance vibration and noise. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 235(4), 428-436. https://doi.org/10.1177/0954411920985994

Transferring sick premature infants between hospitals increases the risk of severe brain injury, potentially linked to the excessive exposure to noise, vibration and driving-related accelerations. One method of reducing these levels may be to travel... Read More about Smartphone monitoring of in-ambulance vibration and noise.

Finding Comfortable Routes for Ambulance Transfers of Newborn Infants (2020)
Conference Proceeding
Partridge, T. J., Morris, D. E., Light, R. A., Leslie, A., Sharkey, D., Crowe, J. A., & McNally, D. S. (2020). Finding Comfortable Routes for Ambulance Transfers of Newborn Infants. In 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). https://doi.org/10.1109/EMBC44109.2020.9175873

Early inter-hospital ambulance transport of premature babies is associated with more severe brain injury. The mechanism is unclear, but they are exposed to excessive noise and vibration. Smart-routing may help minimise these exposure levels and poten... Read More about Finding Comfortable Routes for Ambulance Transfers of Newborn Infants.

Accurate neonatal heart rate monitoring using a new wireless, cap mounted device (2020)
Journal Article
Henry, C., Shipley, L., Ward, C., Mirahmadi, S., Liu, C., Morgan, S., …Sharkey, D. (2020). Accurate neonatal heart rate monitoring using a new wireless, cap mounted device. Acta Paediatrica, 110(1), 72-78. https://doi.org/10.1111/apa.15303

© 2020 The Authors. Acta Paediatrica published by John Wiley & Sons Ltd on behalf of Foundation Acta Paediatrica Aim: A device for newborn heart rate (HR) monitoring at birth that is compatible with delayed cord clamping and minimises hypothermia r... Read More about Accurate neonatal heart rate monitoring using a new wireless, cap mounted device.

Development of a Clinical Interface for a Novel Newborn Resuscitation Device: Human Factors Approach to Understanding Cognitive User Requirements (2019)
Journal Article
Pickup, L., Lang, A., Shipley, L., Henry, C., Carpenter, J., McCartney, D., …Sharkey, D. (2019). Development of a Clinical Interface for a Novel Newborn Resuscitation Device: Human Factors Approach to Understanding Cognitive User Requirements. JMIR Human Factors, 6(2), Article e12055. https://doi.org/10.2196/12055

Background: A novel medical device has been developed to address an unmet need of standardizing and facilitating heart rate recording during neonatal resuscitation. In a time-critical emergency resuscitation, where failure can mean death of an infant... Read More about Development of a Clinical Interface for a Novel Newborn Resuscitation Device: Human Factors Approach to Understanding Cognitive User Requirements.

The development of a clinical interface for a novel newborn resuscitation device; a Human Factors approach to understand cognitive user requirements (2018)
Working Paper
Pickup, L., Lang, A., Shipley, L., Henry, C., Carpenter, J., McCartney, D., …Sharkey, D. The development of a clinical interface for a novel newborn resuscitation device; a Human Factors approach to understand cognitive user requirements

Background: A novel medical device has been developed to address an unmet need of standardizing and facilitating heart rate recording during neonatal resuscitation. In a time-critical emergency resuscitation, where failure can mean death of an in... Read More about The development of a clinical interface for a novel newborn resuscitation device; a Human Factors approach to understand cognitive user requirements.

Neonatal head and torso vibration exposure during inter-hospital transfer (2017)
Journal Article
Blaxter, L., Yeo, M., McNally, D., Crowe, J., Henry, C., Hill, S., …Sharkey, D. (2017). Neonatal head and torso vibration exposure during inter-hospital transfer. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 231(2), 99-113. https://doi.org/10.1177/0954411916680235

© Institution of Mechanical Engineers. Inter-hospital transport of premature infants is increasingly common, given the centralisation of neonatal intensive care. However, it is known to be associated with anomalously increased morbidity, most notably... Read More about Neonatal head and torso vibration exposure during inter-hospital transfer.

An automated quasi-continuous capillary refill timing device (2015)
Journal Article
Blaxter, L., Morris, D. E., Crowe, J. A., Henry, C., Hill, S. J., Sharkey, D., …Hayes-Gill, B. R. (in press). An automated quasi-continuous capillary refill timing device. Physiological Measurement, 37(1), https://doi.org/10.1088/0967-3334/37/1/83

Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of t... Read More about An automated quasi-continuous capillary refill timing device.

Forehead reflectance photoplethysmography to monitor heart rate: preliminary results from neonatal patients (2014)
Journal Article
Grubb, M., Carpenter, J., Crowe, J. A., Teoh, J., Marlow, N., Ward, C., …Hayes-Gill, B. R. (2014). Forehead reflectance photoplethysmography to monitor heart rate: preliminary results from neonatal patients. Physiological Measurement, 35(5), https://doi.org/10.1088/0967-3334/35/5/881

Around 5%–10% of newborn babies require some form of resuscitation at birth and heart rate (HR) is the best guide of efficacy. We report the development and first trial of a device that continuously monitors neonatal HR, with a view to deployment in... Read More about Forehead reflectance photoplethysmography to monitor heart rate: preliminary results from neonatal patients.