A novel approach to monitor head movement inside an MR scanner using voltages induced in coils by time-varying gradients (2023)
Journal Article
Bhuiyan, E. H., Chowdhury, M. E., & Glover, P. M. (2023). A novel approach to monitor head movement inside an MR scanner using voltages induced in coils by time-varying gradients. IEEE Access, 11, 107004-107018. https://doi.org/10.1109/access.2023.3318171

To determine head pose within an MR scanner using measurements of gradient-induced voltage from a multiple coil. A practical implementation of this approach would involve measuring the position-sensitive voltages induced by the imaging gradients rath... Read More about A novel approach to monitor head movement inside an MR scanner using voltages induced in coils by time-varying gradients.

Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023)
Journal Article
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., …Bowtell, R. (2023). Naturalistic Hyperscanning with Wearable Magnetoencephalography. Sensors, 23(12), Article 5454. https://doi.org/10.3390/s23125454

The evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substra... Read More about Naturalistic Hyperscanning with Wearable Magnetoencephalography.

Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding (2023)
Journal Article
Holmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., …Bowtell, R. (2023). Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding. NeuroImage, 274, Article 120157. https://doi.org/10.1016/j.neuroimage.2023.120157

The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to... Read More about Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding.

A ‘Dynamic Kibble’ mass balance for the undergraduate physics teaching laboratory (2022)
Journal Article
Glover, P. M., Milner, C., Rambabu, A., & Varley, D. (2023). A ‘Dynamic Kibble’ mass balance for the undergraduate physics teaching laboratory. European Journal of Physics, 44(1), Article 015201. https://doi.org/10.1088/1361-6404/ac9ef0

Originally envisaged in 1975 to realise the SI unit of electrical current, the Ampere, the Kibble balance has since developed into a powerhouse of modern scientific measurement. By combining theoretical simplicity with precision of measurement, it ha... Read More about A ‘Dynamic Kibble’ mass balance for the undergraduate physics teaching laboratory.

Improved Dynamic Contrast-Enhanced MRI Using Low Rank with Joint Sparsity (2022)
Journal Article
Zhang, J., Najeeb, F., Wang, X., Xu, P., Omer, H., Zheng, J., …Wang, C. (2022). Improved Dynamic Contrast-Enhanced MRI Using Low Rank with Joint Sparsity. IEEE Access, 10, 121193-121203. https://doi.org/10.1109/access.2022.3222313

This work presents a free-breathing dynamic contrast-enhanced (DCE) MRI reconstruction method called low-rank plus sparse (L+S) with joint sparsity. The proposed method improved dynamic contrast performance by integrating an additional temporal Fast... Read More about Improved Dynamic Contrast-Enhanced MRI Using Low Rank with Joint Sparsity.

A lightweight magnetically shielded room with active shielding (2022)
Journal Article
Holmes, N., Rea, M., Chalmers, J., Leggett, J., Edwards, L. J., Nell, P., …Bowtell, R. (2022). A lightweight magnetically shielded room with active shielding. Scientific Reports, 12, Article 13561. https://doi.org/10.1038/s41598-022-17346-1

Magnetically shielded rooms (MSRs) use multiple layers of materials such as MuMetal to screen external magnetic fields that would otherwise interfere with high precision magnetic field measurements such as magnetoencephalography (MEG). Optically pump... Read More about A lightweight magnetically shielded room with active shielding.

Magnetic field design in a cylindrical high-permeability shield: The combination of simple building blocks and a genetic algorithm (2022)
Journal Article
Packer, M., Hobson, P. J., Davis, A., Holmes, N., Leggett, J., Glover, P., …Fromhold, T. M. (2022). Magnetic field design in a cylindrical high-permeability shield: The combination of simple building blocks and a genetic algorithm. Journal of Applied Physics, 131(9), Article 093902. https://doi.org/10.1063/5.0071986

Magnetically sensitive experiments and newly developed quantum technologies with integrated high-permeability magnetic shields require increasing control of their magnetic field environment and reductions in size, weight, power, and cost. However, ma... Read More about Magnetic field design in a cylindrical high-permeability shield: The combination of simple building blocks and a genetic algorithm.

Planar Coil Optimization in a Magnetically Shielded Cylinder (2021)
Journal Article
Packer, M., Hobson, P. J., Holmes, N., Leggett, J., Glover, P., Brookes, M. J., …Fromhold, T. M. (2021). Planar Coil Optimization in a Magnetically Shielded Cylinder. Physical Review Applied, 15(6), Article 064006. https://doi.org/10.1103/PhysRevApplied.15.064006

Hybrid magnetic shields with both active field generating components and high-permeability magnetic shielding are increasingly needed for various technologies and experiments that require precision-controlled magnetic field environments. However, the... Read More about Planar Coil Optimization in a Magnetically Shielded Cylinder.

Qualitative and quantitative assessment of magnetic vestibular stimulation in humans (2020)
Journal Article
Dewey, R. S., Gomez, R., Degg, C., Baguley, D. M., & Glover, P. (2020). Qualitative and quantitative assessment of magnetic vestibular stimulation in humans. Journal of Vestibular Research, 30(6), 353-361. https://doi.org/10.3233/VES-201538

The sensation of phantom motion or exhibition of bodily sway is often reported in the proximity of an MR scanner. It is proposed that the magnetic field stimulates the vestibular system. There are a number of possible mechanisms responsible, and the... Read More about Qualitative and quantitative assessment of magnetic vestibular stimulation in humans.

Optimal Inverse Design of Magnetic Field Profiles in a Magnetically Shielded Cylinder (2020)
Journal Article
Packer, M., Hobson, P., Holmes, N., Leggett, J., Glover, P., Brookes, M., …Fromhold, T. (2020). Optimal Inverse Design of Magnetic Field Profiles in a Magnetically Shielded Cylinder. Physical Review Applied, 14(5), Article 054004. https://doi.org/10.1103/PhysRevApplied.14.054004

Magnetic shields that use both active and passive components to enable the generation of a tailored low-field environment are required for many applications in science, engineering, and medical imaging. Until now, accurate field nulling, or field gen... Read More about Optimal Inverse Design of Magnetic Field Profiles in a Magnetically Shielded Cylinder.

Magnetic-field-induced Vertigo in the MR Environment (2019)
Book Chapter
Glover, P. (2019). Magnetic-field-induced Vertigo in the MR Environment. In eMagRes (191-197). Wiley. https://doi.org/10.1002/9780470034590.emrstm1607

This article discusses the theory behind, and the experimental evidence for, the perception of vertigo in a high magnetic field found in an magnetic resonance imaging (MRI) environment. In this case, the term ‘vertigo’ is not used in its clinical sen... Read More about Magnetic-field-induced Vertigo in the MR Environment.

An intra-neural microstimulation system for ultra-high field magnetic resonance imaging and magnetoencephalography (2017)
Journal Article
Glover, P. M., Watkins, R. H., O’Neill, G. C., Ackerley, R. M., Sánchez-Panchuelo, R., McGlone, F., …Francis, S. T. (2017). An intra-neural microstimulation system for ultra-high field magnetic resonance imaging and magnetoencephalography. Journal of Neuroscience Methods, 290, 69-78. https://doi.org/10.1016/j.jneumeth.2017.07.016

Background Intra-neural microstimulation (INMS) is a technique that allows the precise delivery of low-current electrical pulses into human peripheral nerves. Single unit INMS can be used to stimulate individual afferent nerve fibres during micron... Read More about An intra-neural microstimulation system for ultra-high field magnetic resonance imaging and magnetoencephalography.

Experimental measurement of dynamic concentration of nanofluid in laminar flow (2017)
Journal Article
Hong, J., Liu, S., Yan, Y., & Glover, P. (in press). Experimental measurement of dynamic concentration of nanofluid in laminar flow. Experimental Thermal and Fluid Science, 88, https://doi.org/10.1016/j.expthermflusci.2017.06.022

Nanofluid is thought to have a potential enhancement in heat transfer behaviour of fluid. The nanoparticle concentration in nanofluid is one of the most important factors that affect the nanofluid behaviour. The static concentration was applied in th... Read More about Experimental measurement of dynamic concentration of nanofluid in laminar flow.

A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers (2017)
Journal Article
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., …Brookes, M. J. (2017). A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers. NeuroImage, 149, 404-414. https://doi.org/10.1016/j.neuroimage.2017.01.034

© 2017 The Authors Advances in the field of quantum sensing mean that magnetic field sensors, operating at room temperature, are now able to achieve sensitivity similar to that of cryogenically cooled devices (SQUIDs). This means that room temperatur... Read More about A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers.

Mapping quantal touch using 7 Tesla functional magnetic resonance imaging and single-unit intraneural microstimulation. (2016)
Journal Article
Sanchez Panchuelo, R., Ackerley, R. M., Glover, P. M., Bowtell, R. W., Wessberg, J., Francis, S. T., & McGlone, F. (in press). Mapping quantal touch using 7 Tesla functional magnetic resonance imaging and single-unit intraneural microstimulation. eLife, 5(e12812), https://doi.org/10.7554/eLife.12812

Using ultra-high field 7 Tesla (7T) functional magnetic resonance imaging (fMRI), we map the cortical and perceptual responses elicited by intraneural microstimulation (INMS) of single mechanoreceptive afferent units in the median nerve, in humans. A... Read More about Mapping quantal touch using 7 Tesla functional magnetic resonance imaging and single-unit intraneural microstimulation..

Effect of head pitch and roll orientations on magnetically induced vertigo (2015)
Journal Article
Mian, O. S., GLOVER, P., Li, Y., Antunes, A., & Day, B. L. (2016). Effect of head pitch and roll orientations on magnetically induced vertigo. Journal of Physiology, 594(4), 1051-1067. https://doi.org/10.1113/JP271513

High strength static magnetic fields are known to induce vertigo, believed to be via stimulation of the vestibular system. The leading hypothesis (Lorentz forces) predicts that the induced vertigo should depend on the orientation of the magnetic fiel... Read More about Effect of head pitch and roll orientations on magnetically induced vertigo.

Magnetic field-induced vertigo in the MRI environment (2015)
Journal Article
Glover, P. (2015). Magnetic field-induced vertigo in the MRI environment. Current Radiology Reports, 3(8), Article 29. https://doi.org/10.1007/s40134-015-0112-1

This review discusses the theory behind, and the experimental evidence for, the perception of vertigo in a high magnetic field found in a magnetic resonance imaging (MRI) environment. Recent experiments have shown that there is an eye nystagmus respo... Read More about Magnetic field-induced vertigo in the MRI environment.

A dynamic model of the eye nystagmus response to high magnetic fields (2014)
Journal Article
Glover, P. M., Li, Y., Antunes, A., Mian, O. S., & Day, B. L. (2014). A dynamic model of the eye nystagmus response to high magnetic fields. Physics in Medicine and Biology, 59(3), https://doi.org/10.1088/0031-9155/59/3/631

It was recently shown that high magnetic fields evoke nystagmus in human subjects with functioning vestibular systems. The proposed mechanism involves interaction between ionic currents in the endolymph of the vestibular labyrinth and the static magn... Read More about A dynamic model of the eye nystagmus response to high magnetic fields.

Reference layer artefact subtraction (RLAS): A novel method of minimizing EEG artefacts during simultaneous fMRI (2013)
Journal Article
Chowdhury, M. E., Mullinger, K. J., Glover, P., & Bowtell, R. W. (2014). Reference layer artefact subtraction (RLAS): A novel method of minimizing EEG artefacts during simultaneous fMRI. NeuroImage, 84, 307-319. https://doi.org/10.1016/j.neuroimage.2013.08.039

Large artefacts compromise EEG data quality during simultaneous fMRI. These artefact voltages pose heavy demands on the bandwidth and dynamic range of EEG amplifiers and mean that even small fractional variations in the artefact voltages give rise to... Read More about Reference layer artefact subtraction (RLAS): A novel method of minimizing EEG artefacts during simultaneous fMRI.